Reasonable Price of Electro Galvanized Wire

Ref Price:
Loading Port:
Xingang Port, China
Payment Terms:
TT or LC
Min Order Qty:
20 M.T. m.t.
Supply Capability:
2000M.T. Per Week m.t./month
  • OKorder Service Pledge
  • Quality Product
  • Order Online Tracking
  • Timely Delivery
  • OKorder Financial Service
  • Credit Rating
  • Credit Services
  • Credit Purchasing

Add to My Favorites

Follow us:

Description of Reasonable Price of Electro Galvanized Wire

Galvanized wire can be divided into: Electro galvanized iron wire & Hot dipped galvanized iron wire

1.Materials: Low carbon steel wire(Q195 )

2.Wire diameter:  0.4mm -4.0mm

3.Zinc coating: 10 -25g /m2

4.Tensile strength:  400--600N/mm2; 

5.Elongation:  min15%

6. Packing: 1-100kgs/spool or in big coil to 800kgs

7. Package:

Inside plastic film, then weave nylon bag cloth.

Inside plastic film, then hessian cloth.

With spools

We can also pack as your request.

8. Application: redrawing,producing nail,binding etc.

Electro Galvanized Wire is mainly used in construction, fencing and binding. This kind of wire is also extensively used in construction, handicrafts, woven wire mesh, express way fencing mesh, packing of products and other daily use. Hot-dipped galvanized steel wire can be supplied in the form of coil wire, cut wire or tie wire to meet our customers different needs.

9. Popular Specifications:

Electro Galvanized Wire

Wire gauge

SWG(mm)

BWG(mm)

Metric(mm)

8

4.05

4.19

4.00

9

3.66

3.76

4.00

10

3.25

3.40

3.50

11

2.95

3.05

3.00

12

2.64

2.77

2.80

13

2.34

2.41

2.50

14

2.03

2.11

2.50

15

1.83

1.83

1.80

16

1.63

1.65

1.65

17

1.42

1.47

1.40

18

1.22

1.25

1.20

19

1.02

1.07

1.00

20

0.91

0.84

0.90

21

0.81

0.81

0.80

22

0.71

0.71

0.70

23# to 38# also available (wire diameter from 0.17-4.5mm)

Factory

 reasonable price of electro galvnaized wire

Product Photos

 reasonable price of electro galvanized wire

Delivery

 reasonable price of electro galvanized wire

 

 

Q:I have a grounding wire for my HIDs which I need to increase the length for. How do I do this?
Get a length of wire the same gauge or larger than the original wire. Solder the wire to the old wire and run it to a good ground. If you can't get it soldered a crimp connector will work,but not a good idea under the hood of a car, temporary at best
Q:i need the wire diagram for a kenwood kdcmp4032.... i mainly need to know which wire to hook up the remote wire for an amp.
it is the blue wire now if there are 2 blue wires the one with the white stripe is the amp remote wire the other is for the power antenna and will only activate when the radio is on as in tuner am/fm not when the cd is playing
Q:A potential difference of 13 V is found to produce a current of 0.37 A in a 3.1 m length of wire with a uniform radius of 0.42 cm.(a) What is the resistance of the wire? (b) What is the resistivity of the wire? Please show work.
Voltage (Volts) = Current (Amps) times Resistance (Ohms) or V=IxR = R = V/I = 13/0.37 = 35.14 Ohms Resistance = Resistivity * Length/Area The longer the wire is, the more resistance it has. The larger the crossectional area of the wire (pi times radius^2), the less resistance it has Longer wires have more resistance, thicker wires have less 35.14 = Resistivity * 3.1/pi*0.0042^2 Resistivity = 35.14*pi*0.0042^2/3.1 = 6.281 x 10^-4
Q:what do i do? the wire just snapped.
There's not much you can do over the weekend... Just call first thing Monday morning so they can repair it... in the mean time be careful about what you eat... no sticky stuff, etc. Hang in there.. it'll be okay.
Q:Can anyone give me some info or a website with info on which type of wire carries sound waves best?
Wire does not carry soundwaves, at least not unless the ends of the wire have tin cans on them, and the wire is pulled taut between them! Wires can carry electrical signals which can be used to reproduce the sounds that caused them. This is how sound comes from such as your stereo system's speakers. Maybe that's what you actually mean? If so, copper wires (insulated, of course) are what you want, and if the distance you run the wires is great, the heavier the wire (gauge) the better. If you are transmitting high power to speakers, the wires have to be capable of handling the electrical current involved.
Q:How do I wire with reg 5 wire T-Stat Installing a 2 ton Goodman A/C cond unit to a old Carrier Heat pump AHU with emergency heat strip.
red is your low voltage green is your fan yellow is your cool brown is your com orange is your heat how many wires do you have on the old one should be color to color
Q:I am installing an amp in my '04 Chevy crew cab truck and am running new wire for the speakers. I was able to get the fronts wired but when I broke into the back doors there is a feedthrough connector where I need to put the wires through. I am sure this connector contains the wires for my windows, door lights and the current speaker wires. My question is how do I get my new 18 gauge wires through to the speakers, am I missing something?Thanks in advance!!
a generic AC voltmeter is designed to study 50/60 Hz Ac from the mains, no longer audio voltage, so do no longer count number on that analyzing. an ordinary element to do is in basic terms swop over factors. you have tried the audio equipment with yet another radio and that they artwork, now try yet another radio on your automobile with your audio equipment, in the event that they do no longer artwork, it leaves in basic terms the speaker wires. in the event that they do artwork, this is the radio. Oops i'm forgetting there could be a separate amp, so which you will could desire to objective yet another amp too to get rid of the defective ingredient. Do the element it somewhat is least complicated first with any success you will no longer ought to do each and every thing.
Q:My dad is trying to wire a electric cook top...it has three wires (black, red, and copper). His junction box has four wires (black, red, white and copper). He first wired the black to black, red to red and copper to copper, he capped the white wire in the junction box. The cook top did not work. Then he connected the white wire with the two copper wires, and the cook top now works. So the question is will this connection work or will it cause a problem? And if it causes a problem what can he do to resolve it?
Hi There, This what I would do. The black and red wires from the cooktop are fine and can be connected to the black and red wires in the junction box. Check the copper wire from the stove and see where it is connected. It is probably a neutral wire used to supply 120 volts for a clock, lights or other control function. If that is the case I would exchange it for a properly sized insulated white wire. This white wire can be connected to the white wire in the junction box. Then: Connect the copper wire to a metal part of the cooktop to use as a ground wire. This wire can then be connected to the copper wire in the junction box. This would be a typical modern 4-wire 240 volt setup. Hope this helps, Al
Q:How is the line differ from a neutral and ground wires in a three prong plug?
In your standard outlet, (NEMA 1-15 or 5-20 receptalce/plug): The 'Line' is the smaller slot/prog The 'Neutral' is the large slot/prong The ground is the 'pin'/prong.
Q:Would crepe paper stick on chicken wire?
Crepe paper needs an adhesive to make it stick to a surface, such as white glue. However, it gets messy once dampened, as the colors may bleed. Instead, I would consider working with paper mache or plaster gauzing strips, which would provide a strong skin over the chicken wire. Both can be primed with gesso then decorated with acrylic paints. If this is a sculptural piece you want to keep, we would also suggest varnishing it for protection.
SOUTH PORT,it is a factory which is specially in galvnaized wire, hot dipped galvnaized wire, cut wire, etc. All our products are backed by our Quality Management system which has been approved and accredited by the CQC to ISO.

1. Manufacturer Overview

Location Hebei, China
Year Established 2005
Annual Output Value Above US$ 1,500,000
Main Markets Mid East; Eastern Europe; North America; America; and other coutries
Company Certifications ISO 9001

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Tianjin
Export Percentage 70%
No.of Employees in Trade Department 60 People
Language Spoken: English; Chinese;
b)Factory Information  
Factory Size: Above 15,000 square meters
No. of Production Lines Above 5 producce line, 120 units machine
Contract Manufacturing OEM Service Offered; Design Service Offered
Product Price Range Reasonable; Average

Send your message to us

This is not what you are looking for? Post Buying Request

Hot Searches

Related keywords