Specifications of Coil Wire Rod:
Steel Grade: SAE1006-1018B Standard: ASTM, GB
Diameter: 5.5mm, 6.5mm, 7mm,8mm,9mm,10mm,12mm,14mm
Diameter tolerance: ±0.3 6.5mm can be drawing into 2mm 8.0mm can be drawing into 3mm
Type: in Coil, each coil weight about 2MT Coil Diameter: 1.2M Coil Length: 1.6-1.7M
Brand Name: N-RIVER Technique: Hot Rolled Place of Origin: China Mainland
Chemical Composition:
Please kindly find our chemistry of our material based on SAE1006 and SAE1008 as below for your information
Grade |
Chemical Composition (%) | |||||
C |
Mn |
S |
P |
Si |
B | |
SAE1006B |
0.03~0.07 |
0.32max |
0.045max |
0.040max |
0.30max |
0.0008min |
Mechanical properties | ||||||
Yield strength(N/mm2) |
Tensile strength(N/mm2) |
Elongation (%) | ||||
250-280 |
350-380 |
≥32 | ||||
Grade |
Chemical Composition (%) | |||||
C |
Mn |
S |
P |
Si |
B | |
SAE1008B |
0.10max |
0.3~0.50 |
0.050max |
0.040 max |
0.15max |
0.0008 min |
Mechanical properties | ||||||
Yield strength(N/mm2) |
Tensile strength(N/mm2) |
Elongation (%) | ||||
≥195 |
315-430 |
≥30 |
Usage and Applications of Coil Wire Rod:
After hot-rolled the products shaped into coil and delivery as finished product, including round, square, rectangular, hexagonal and so on. Since most of the products are round, it is generally called wire rod. Carbon steel wire rod is widely used in construction and manufacturing. Carbon steel wire rod is mainly used for reinforcement of reinforced concrete and welded structure or reprocessed (roberts , nail, etc.) materials, especially used to produce wire drawing, welding electrode, nails, spring, electronic, precise machinery parts and so on.
Production Process of Coil Wire Rod:
1-Furnace 2-Roughing Mill 3-High-speed Finishing Mill 4-Water-cooled Device 5-Coiling Device
6-Cooling Device 7-Chain Conveyer 8-Spool Collecting Device 9-Spool Down Device 10-Hook Conveyer
Packaging & Delivery of Coil Wire Rod :
Packaging Detail: products are packed in coil and then shipped by container or bulk vessel
Delivery Time: within 45 days after received deposit or LC.
Label: to be specified by customer, generally, each bundle has 1-2 labels
Trade terms: FOB, CFR, CIF
Coil Wire Rod in Container
Coil Wire Rod in Bulk Vessel
Note:
1. Our products are produced according to national standard (GB), if not, supply according to national standards (GB) or agreement as customer required.
2. Other Grade and Standard carbon steel wire rod we can supply:
Grade: H08A, 30MnSi, 62B-82B
Standard: AISI, BS, JIS, DIN
The Minimum Order Quantity of these products is high, and need to be confirmed.
3. We can not only supply carbon steel wire rod; if you need anything about building materials, please contact us.
4. Please send us your detail specifications when inquire. We will reply to you as soon as possible. We sincerely hope we can establish a long stable business relationship.
- Q: to which wire in the back of my car radio do i hook my remote wire to from my amplifier?
- Most factory radios, your Corolla included do not have a dedicated remote wire. Some will have a power antenna wire that can sometimes be used but the Corolla doesn't have a power antenna. You want to connect the amp remote to a switched 12V + source. The appropriate wire on your factory radio is the gray wire. That way, the amp will turn on whenever you turn on the ignition. Alternatively, you can connect the remote directly to any switched 12V wire.
- Q: So on my ceiling fan I have a white, black, green, and blue wire. In the ceiling I have a green, white, black, red, and bronze wire. What gets connected to what? Thanks for the help!
- always look at youtube for advise on home projects they have videos you can watch over and over if needed. it saved me many times. good luck!
- Q: just need a little help to make right.just wiring an outlet from building to breaker box outside.. which way is the right way to wire it to a breaker then the box. Got the right breaker. Thanks
- This doesn't sound like an easy answer without seeing it. For instance, how long is the wire run; is it entirely outside (if so, then you'll need either conduit for the full run, or UF-B rated wire buried below the freeze line with conduit where it exits the ground to the Service Panel). Outside receptacles should also be GFCI (Ground Fault Circuit Interrupter) protected. A single pole 20amp breaker should be used for a 12/3 wire. Load wire (black) goes into the screw of the breaker; the neutral (white) wire screws into the neutral bus bar of the service panel (breaker box), and the bare ground wire screws into the ground bus bar. Since these wires are interchangeable, it really doesn't matter which side of the panel you hook the neutral and ground wire to. BE CAREFUL!!!!! The main bus bars can still be hot (charged) even with the power turned off. If you ground yourself and touch the wrong thing, you'll be wondering what went wrong from the great beyond. Get a basic electricity book from Home Depot, or look on youtube. If you're not 100% confident, please leave this to a professional.
- Q: I am replacing an old outlet with a GFCI and I have encountered a red wire...what is the red wire for?
- There might be a three way switch on the circuit,or a red wire can indicate a second hot wire. It gets complicated very fast, however almost all homes have these red wires in them, and they serve an imporatant service. Could be a red wire is used when you come out of a switch with hot and go into another switch as neutral.
- Q: I was looking at the wiring of my current thermostat and I want to know why it's wired the way it is...The yellow wire was wrapped around the white terminal and the yellow terminal. And the white wire was wrapped the around the Orange terminal. The red and green wires were each wrapped around their respective terminals. And the blue wire wasn't connected to anything. Why would the electrician have wrapped the yellow wire around 2 terminals? Is that normal? Also, I tried installing a new thermostat but the heating is not working. The fan works but it just blows room temperature air. The new thermostat only had 4 terminals for R, Y, W, G. I connected the wires I had to their respective terminals. However, I think it may not be working because I have a probably have a heat pump. Any Ideas why else it might not be working? Thanks a lot!
- You should take sketches of the thermostats and wires to your favorite plumbing heating store, and talk to a service person, if you feel competent enough to do the proper connections yourself. Also, include details of the thermostat wiring connections to your heating unit. Otherwise, get such a person to come over to your house to do the work.
- Q: i have a 1995 chevy S10 blazer and i noticed that it has 5? speakers in the door and 6x9 in the back i started looking and i found that it has 4x6 in the dash with cardboard over it but it don't have speaker wire ran for it i think its going to be difficult running wire for it but what gauge of wire should i use? and should i run the speaker wire to the head unit how would i hook the speaker wire to the aftermarket head unit or should i run it to the 6x9 or 5? i already have a pair of 4x6's ready to be installed in it as soon as i find out how to do it and what size of speaker wire it is im going to be doing it by myself
- 16 okorder /
- Q: I would like to know how to wire my West Marine VHF Radio.Coming out the back of the radio is a red wire, a white wire, and two black wires. The white wire and one of the black wires are a thinner gauge then the other black and red wires. Any solutions out there? Thanks
- You could solder (best), or crimp connect a waterproof In Line fuse to the red wire, then connect it to a terminal Ring, and put over the red + battery post, then ground the black wire, by connecting a Terminal ring to it and put it over the NEG.- battery post. The In-Line fuse is circuit protection, OR you can by-pass this by conecting to a spare fuse on the Panel (red +), then ground the black wire to the Neg on the battery or neg - on the panel (fuse block). Direct connection to the battery is best, the other wires probably go to the Aux. Speaker which you will need as the speakers on the radio are too small to be heard over engine noise. Soldering works BEST, then coat with Liquid Lectric tape, or heat shrink tubing for a water resistant seal on the wires, and a good Marine connection. E-mail is open if further assistance is needed.
- Q: 2.4) A wire has a resistance of 19.2 . It is melted down, and from the same volume of metal a new wire is made that is 5 times longer than the original wire. What is the resistance of the new wire?
- the quantity of twine ought to stay the comparable that's A L, so once you double L you decrease A in 0.5. Resistance = Rho L/A, so the recent twine has 4 cases the resistance or 20 ohms.
- Q: I have two alpine 1242d. I need to wire them parallel parallel. Ive seen many pictures on how to do it but im still a little confused. Okay first off do i need any special type of wiring or will my 4awg wire work. Because it shows multiple wire connections where the wires combine. The positive connect from an existing wire already running to the amp. If anyone understand what i mean can you explain it to me. Thank you much appreciated!
- First off, your 4 awg wire will work for powering your amp but its right on the edge, I would go with 1/0 if your amp terminals will accept that gauge. Second, you don't have to make all those connections with one speaker wire, that diagram is simply showing you the current path. If you want a really simple way to do this, cut three strips of speaker wire and strip the ends about 3/8 of an inch. stick one end of each positive wire into one of the positive terminals on any voice coil. now run one wire to the + amp terminal, one wire to the other + voice coil on the same sub, and one wire to either of the + voice coil terminals on the other sub. now strip a fourth wire and connect the two + terminals on the second sub. repeat the same procedure for the - terminals. I reccomend using 14 or 16 gauge speaker wire for this. Good luck
- Q: One wire has part of the plastic coating on the end, the other wire does not.
- the lead is the wires showing. lead wire can also mean attaching a wire and feed it through a wall attach other end to the wire and pull it through. Now if you need both ends to have wire showing take a utility knife firmly place wire on block of wood and lightly cut through the caseing. thats the thick wire that en cases the other wires and peal back and then cut it off. then carefully hold blade of utility knife and wire aganst your thumb on a 45 degrees away from you and pull that will strip the plastic off the wires hope that answers your question dave
1. Manufacturer Overview
Location | Qianan, China |
Year Established | 2002 |
Annual Output Value | Above US$ 2,500 Million |
Main Markets | America, Japan, England, Germany, Korea, South Aisa and Southeast Aisa |
Company Certifications |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Tianjin |
Export Percentage | 60% - 70% |
No.of Employees in Trade Department | 21-30 People |
Language Spoken: | English; Chinese |
b) Factory Information | |
Factory Size: | Above 900,000 square meters |
No. of Production Lines | Above 10 |
Contract Manufacturing | OEM Service Offered; |
Product Price Range | High; Average |
Send your message to us
Coil Wire Rod
- Loading Port:
- XINGANG PORT,China
- Payment Terms:
- TT or LC
- Min Order Qty:
- 25 Tons m.t.
- Supply Capability:
- 100,000 Tons Per Month m.t./month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords