High Quality Indented PC Steel Wire
- Loading Port:
- China Main Port
- Payment Terms:
- TT or L/C
- Min Order Qty:
- 20TON m.t.
- Supply Capability:
- Base On Order m.t./month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Applications of High Quality Indented PC Steel Wire
Low relaxation wire used for prestressed steel structures, such as construction of large scale highways, railroad, etc.
SIZE of High Quality Indented PC Steel Wire
DIA. 4.0mm, 4.8mm, 5.0mm, 6.0mm, 7.0mm, 7.5mm, 8.0mm, 9.0mm, 10.0mm.
Size/mm | Tolerance/mm | Area/mm2 | Theoretical weight- g/m | Wire Cross-sectional Size | Rib Pieces | Lay Length (Lg)/mm | |||
Basic-roundDia(D1)/mm | OutioneDia(D)/mm | Rib Width(jk)/mm | Rib Height(jg)/mm |
|
| ||||
4.00 | ±0.04 | 12.57 | 98.6 | 3.85±0.05 | 4.25±0.05 | 0.90~1.30 | 0.15~0.25 | 4 | 24-30 |
4.80 | ±0.05 | 18.10 | 142 | 4.60±0.05 | 5.10±0.05 | 1.30~1.70 | 0.20~0.30 | 28-36 | |
5.00 | 19.63 | 154 | 4.08±0.05 | 5.30±0.05 | 1.30~1.70 | 0.20~0.30 | 28-36 | ||
6.00 | 28.27 | 222 | 5.80±0.05 | 6.30±0.05 | 1.60~2.00 | 0.30~0.40 | 30-38 | ||
7.00 | 38.48 | 302 | 6.73±0.05 | 7.46±0.10 | 1.80~2.20 | 0.30~0.40 | 35-45 | ||
7.50 | 44.18 | 347 | 7.25±0.05 | 7.95±0.05 | 1.90~2.30 | 0.30~0.40 | 40-50 | ||
8.00 | ±0.06 | 50.26 | 394 | 7.75±0.05 | 8.45±0.10 | 2.00~2.40 | 0.30~0.40 | 40-50 | |
9.00 | 63.62 | 499 | 8.75±0.05 | 9.45±0.05 | 2.10~2.70 | 0.30~0.40 | 42-52 | ||
10.00 | 78.54 | 616 | 9.75±0.05 | 9.75±0.05 | 2.50~3.00 | 0.30~0.40 | 45-58 |
Tensile Strength Grade of High Quality Indented PC Steel Wire
1470Mpa, 1570Mpa, 1670Mpa and 1770Mpa.
Packing of High Quality Indented PC Steel Wire
Each coil is strapped by steel bands and fully wrapped in anti-rust paper & P.P woven sheet.
Coil weight: 1.7-2.2 tons.
ID: 1.7-1.8M.
OD: 2.2-2.5M.
Standard of High Quality Indented PC Steel Wire
ASTM A421, BS5896, JIS G 3536, ISO 9001-2000 or according to customers' requirements.
- Q:I bought Nexxtech Evolution series 16 gauge 30' wire to be able to bring my rear speakers farther back in my room. I have an Altec Lansing 5.1 speaker system with remote and all the speakers connect to the back of the sub. (front are red wire, center is blue, and rear is gray) they are all have the black wire and the colored wire. The wire I just bought are brown, and have a stripe of gray on the second wire (polarized wires) but the ones I bought are much thicker wire... will it still work to just strip/twist/tape the wires to extend the rear speakers? or did I buy the wrong wire? and also, how do I know which to twist with which? (the ones I bought aren't really that clear on which is which... which end is positive and which is negative).Answer quickly please!
- First of all, wires really don't make a difference at all - not for speakers anyway. Any cheap wire from home depot will work fine. The stuff they use for lamps works very well. Secondly, the colors, stripes, etc. don't make a difference either. Here's the only thing that matters - make sure you connect the (+) or RED wire from your amp to the (+) or RED terminal on your speaker. Likewise with the other wire. That's all you need to keep track of. If you don't do this, then your bass will suck.
- Q:I bought a chandelier from Ikea and I am having trouble wiring it. The colors do not match the colors in the ceiling. There is also one extra wire in the ceiling. This chandelier is to be controlled by a switch. Chandelier wire colors:WhiteBlackGreen/yellowCeiling wire colors:RedYellowBareBlackPlease help! Thank you!
- You do have a problem there, the colors in the ceiling are not standard. So black goes to black(hot), then green/yellow goes to the bare copper (ground). Now the tricky part is, you'll need a test meter to figure out if the yellow in the ceiling is the neutral which should go to the white. I would test between the yellow and the black in the ceiling (with the switch on) to see if there is 120V there. If there is problem solved, if not check between the red and yellow. I am guessing that either the red or the black will be the hot and the yellow will be the neutral. The one you do not use, I would cap off either by putting a wire nut on it or electrical tape.
- Q:Why do two parallel wires carrying currents in opposite directions repel each other?
- Parallel Wires
- Q:Or speaker wire that has an RCA plug on one end?If you know of something that is inexpensive without me having to get another preamp, please help.(this is for a turntable preamp by the way, my preamp only has RCA output.)
- You can't connect speakers directly to a turntable preamp. You need an amp.
- Q:I have a 1989 Nissan 240sx. Somehow the fan caught a hold of the wiring harness and tore all the wires. any idea how much it's going to cost?
- Buying a wiring harness will be prohibitive, and even transplanting one from a wrecking yard can be expensive. The harness can be repaired by splicing in pieces of wire where wire is missing and splicing together damaged pieces of wire. It is tedious but not particularly time consuming - I spliced in a section of harness after an engine fire in about 2 hours, working slowly.
- Q:running wire from wall out let to a on and off switch and then to another outlet
- Here's what you do: Run the thingy to that other thing. Make sure you don't forget that second step. When you're done, stop working. Then call an Electrician to fix what you did.
- Q:How do I find the remote wire on the back of my stock Ford Focus strereo? I have a line output converter to connect the rca cables to the deck, but I cannot tell wich wire is the remote wire. How can I track this wire down to connect it to the amp?
- usually stock decks wont have a remote wire for an aftermarket amp but if you have a power antenna you can use the same wire that turns that on
- Q:What's the metal wire fabric?Such as title
- Because the implant metal wire fabric because of the overall color bright, if there is a light metal, can reflect the specific metallic luster. But note that not only the characteristics of metal wire fabric in metallic luster, and anti-static, with anti radiation, more conducive to regulate all aspects of the body
- Q:While updating the parents basement we needed to replace a very very old 3 way switch. However, the wiring to the Fluorescents seems extreme to me. Here is how i can describle the layout. Panel - junction box - double splice (one to light fixture and one to threeway switch below it)-. From that threeway switch 12-3 wiring to upstairs landing with other threeway switch resides. How should I make my connections to switches? If the other swtiches were not so old I would just copy them.
- A hot wire from the panel to the first three way switch on the common screw. Two runner wires between the two switches on the other two screws. A wire from the common screw on the second switch to the hot wire on the light fixtures. A neutral wire to the light fixtures from the panel. Look at Bert's pictures.
- Q:subs - dvc 4ohm 2 of them 600wattrms on each wiring it to a 1200 watt amp same brand as sub amp is 1 ohm stable to i wire the subs together and then to the amp a 1ohm? that would give each sub 600 watts right?
- The current passing through the wires will cause the wires to heat up if not sufficient guage. Think of the millions of little electrons pushing and shoving back and forth, all this action causes friction on a molecular level and of course we all know friction equals heat. In a bigger guage wire there is more room for the same number of electons. It's really that simple. Use as heavy a guage speaker wire that you can. You will have no signal loss and little heat.
1. Manufacturer Overview |
|
---|---|
Location | Qianan, China |
Year Established | 2002 |
Annual Output Value | Above US$ 2,500 Million |
Main Markets | America, Japan, England, Germany, Korea, South Aisa and Southeast Aisa |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | Tianjin |
Export Percentage | 60% - 70% |
No.of Employees in Trade Department | 21-30 People |
Language Spoken: | English; Chinese |
b)Factory Information | |
Factory Size: | Above 900,000 square meters |
No. of Production Lines | Above 10 |
Contract Manufacturing | OEM Service Offered; |
Product Price Range | High; Average |
Send your message to us
High Quality Indented PC Steel Wire
- Loading Port:
- China Main Port
- Payment Terms:
- TT or L/C
- Min Order Qty:
- 20TON m.t.
- Supply Capability:
- Base On Order m.t./month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products