WQ Vertical Sewage Centrifugal Submersible Water Pump

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
100 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

1. Product Introduction

WQ series submersible sewage pump is mainly used for municipal work, industrial building, hotels, hospitals, civil air defense, mines, etc. It can be widely used in transfer waste water, rainwater and living water etc. which contains solid grains and various long fibers CNBM WQ series sewage submersible pump have many advantages, such as, hi-efficiency, circumvolution proof, blockage free, auto-coupling, hi-reliability and auto-control, etc.

 

2. Technical Performance

Discharge diameter: 50~600 mm

Capacity: 10~8000m³/h

Head: 5~60m

Power: 1.5~315kw

Diameter of pass solids: 20~145mm

 

3. Operation Condition

1). Rated Voltage: 380V(660V), Frequency: 50Hz, 3-phase AC.

2). Temperature of medium under 40ºC.

3). PH value: 4~10.

4). Volume ratio of solid in medium below 2%.

5). Density of medium should be lower than 12000kg/m³.

 

4. Structure Characteristic

WQ series submersible sewage pump is equipped with status indicator and protection device to ensure for pump safe and reliable operating.

1). The unique cable airproof is adopted, avoid leakage of cable.

2).  Heat protector in stator assure of operating life of the motor.

3).  The pump adopts outer recycling cooling design with motor power more than 18.5kw, which can keep the pump operating safely under the lowest water level.

4).  A floating switch is installed at the bottom of motor chamber to protect the mechanical seal in the motor side.

5).  The oil-water probe is installed at the up end of the oil chamber between pump and motor that can protect the mechanical seal in the side. If leakage occurs, the system will signalize and start protection.

6).  Adopt perfect mechanical seal, the sealing material adopt tungsten carbide, silicon carbide and hard metal alloy, which can prevent the water from entering into the motor, and keep the operating reliable and safety.

7).  The auxiliary impeller can balance the pressure outside of the mechanical seal, prevent the water entering into the oil chamber and prolong the life of the motor.

8).  Unique impeller design, wide passage allow large solid and long fiber passing through freely, it features non-clog, convolve-proof and good passing ability.

9).  The changeable wearing ring is installed between the impeller and the volute to keep the optimum operation conditions.

 

5. Impeller Design Characteristics

For the feculence pass freely, it must be widen the flowing passage of impeller, for the big pump, can used for double-vane, or three-vane, for the small pump, it used for single(double) flowing passage, like a bent pipe has same section, it has a good passing characteristic, avoid stop, convolve caused by slowing current possibly. The especially flowing passage of impeller, cooperate with logical volute, made the paper, soft goods, garbage bag and other material in sewage can passing freely and the pump have no vibration in the course of running-in and load through the impeller balance between dynamic and static state.

 6. FAQ for WQ pumps

1). Can I get trained on CNBM products?

Yes, we provide training courses in our factory (products, general and specific pump technology, hydraulics, and practical applications). Please consult your sales manager or get in touch with our headquarters for more information.

2). Are your pumps cheaper than those of your competitors?

CNBM aims to give its customers the highest standards of quality and service and delivery times, all at a reasonable price.

3). How long is your warranty?

Unless otherwise expressly authorized in writing, by specifying a longer period or different conditions, CNBM states that, for a period of twelve (12) months from delivery date, all Products supplied are free from defects in materials and workmanship, and conform to the applicable specifications. Either the delivery documentation or the invoice must be provided to prove delivery date. In absence of such documents, the production date appearing on the product label may suffice.

 

WQ Vertical Sewage Centrifugal Submersible Water Pump

WQ Vertical Sewage Centrifugal Submersible Water Pump



Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Which water pump do i need for a 1997 mercury 25 hp 2 stroke?
Well to start of, and two, A 25 hp does not have a water pump, like a car, it has am impeller driven by the out board motors gear system
Q:Can I drive a car that has a broken Water Pump?
Depends on how bad the leak, and the condition of the bearings. If the pump is just leaking you may be OK. If the fan is mounted directly to the pump and is grinding or wobbling around, don't do it. The fan could break loose and cause expensive damage. Good luck
Q:Why would my garage charge me to take home the broken water pump of my VW Golf?
they shouldnt charge u since it technically trash but ive heard car manafactures buy back parts to refurbish them and resale them maybe he just wanted the money from not being able to do that
Q:USB controlled water pump?
I'd look for a USB IO module, add a relay, and switch a standard pump.
Q:subaru imprezza water pump ?
At a minimum, you have to pull the engine out of the bay... not always the easiest thing in the world.
Q:What are the new regulations in the design of main and auxiliary water bin and water pump room in coal mine?
The main water bin must have a main bin and an auxiliary warehouse. When a sump is cleaned, another water tank can be used normally.When the normal water inflow is below 1000m3/h, the effective capacity of the main water tank should be able to accommodate the normal discharge of 8h.The effective capacity of the main water bin can be calculated by pressing type in the mine where the normal water inflow is greater than 1000m3/h:V = 2 (Q+3000)Effective capacity of V-- main water bin in type m3;Q-- mine hourly normal water inflow, m3.However, the total effective capacity of the main water storage tanks shall not be less than the normal water inflow of 4h.The effective capacity of the water tank in the mining area shall be able to accommodate the normal water inflow in the 4H mining area.There is a big difference between the maximum water inflow and the normal water inflow in the mine. The drainage capacity and the water storage capacity should be specially designed.The water inlet chamber should be set up. A sedimentation tank shall be provided for the filling of water sand, hydraulic coal mining and other gushing water with a large amount of impurities. The water storage capacity of short positions must often remain above 50% of total capacity.
Q:What are the steps to take out a water pump for a grand am 2004?
You did not say if you have a 4 cylinder or a 6 cylinder. The 6 is really easy so I will assume you have a 4.If equipped with an automatic transmission, remove the exhaust manifold. Refer to Exhaust Manifold Removal in Engine Mechanical - 2.2L (L61). Drain the cooling system. Refer to Cooling System Draining and Filling . Raise and suitably support the vehicle. Refer to Lifting and Jacking the Vehicle in General Information. Remove the right front tire and wheel. Refer to Tire and Wheel Removal and Installation in Tires and Wheels. Remove the front fender liner. Refer to Front Fender Liner Replacement in Body Front End. Remove the access plate on the water pump sprocket from the timing cover. Install J 43651 to the water pump sprocket. Use the access plate bolts to secure J 43651 to the engine front cover. Remove the bolts that secure the sprocket to the water pump. Remove the bolt (1) that secures the engine block to the water pump. Remove the bolt (2) that secures the engine front cover to the water pump. Remove the feed pipe that joins the thermostat housing to the water pump. Remove the 2 bolts that secure the water pump to the engine block. Remove the water pump.
Q:The water well pump is surging water pressure is dropping and keeps tripping the breaker?
I'm not clear on what is happening. Surging water pressure can mean that there is no air cushion in your water tank and the pump suddenly is overloaded. This would be indicated if the pump turns on and off in rapid sequence. If you have 50 psi then the system is certainly pressurized and it would appear that the pump is working. If there has been a loss of air cushion then depending on the type of system you have you may have to replace the expansion tank or drain and refill it to get the air cushion back. If there is a tank on your system that has a fitting that looks like the air fitting on a bicycle tire then that is where you can pump in air to restore the air cushion. If the pump constantly runs, and then blows a breaker you may also want to check the pressure switch that turns the pump on and off.
Q:What is the reason for the overload of the water pump indicator?
In this case, first check the frequency of the pump in the acceleration and deceleration time, to see how many seconds, 7.5KW10 seconds or so, 11KW 10 to 15 seconds, to see whether the peak water supply, low voltage and so on! Hope to be of some help to you!
Q:I have already replaced the thermotast but my vw bug still overheats .it blows water thru the tailpipe?
sounds like a head gasket to me, I'd get it checked immediately.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range