WQ Series Sewage Submersible Pump

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT or L/C
Min Order Qty:
1 Sets set
Supply Capability:
1000 Sets Per Month set/month
Inquire Now Customer Service

Contact us by

(1) WeChat
(2) Whatsapp: +8617190086776

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

All details for WQ Series Sewage Submersible Pump:

 

1. Product Introduction of WQ series Sewage Submersible Pump

WQ series submersible sewage pump is mainly used for municipal work, industrial building, hotels, hospitals, civil air defense, mines, etc. It can be widely used in transfer waste water, rainwater and living water etc. which contains solid grains and various long fibers CNBM WQ series sewage submersible pump have many advantages, such as, hi-efficiency, circumvolution proof, blockage free, auto-coupling, hi-reliability and auto-control, etc.

 

2. Technical Performance of WQ series Sewage Submersible Pump

Discharge diameter: 50~600 mm

Capacity: 10~8000m³/h

Head: 5~60m

Power: 1.5~315kw

Diameter of pass solids: 20~145mm

 

3. Operation Condition of WQ Series Sewage Submersible Pump 

1). Rated Voltage: 380V(660V), Frequency: 50Hz, 3-phase AC.

2). Temperature of medium under 40ºC.

3). PH value: 4~10.

4). Volume ratio of solid in medium below 2%.

5). Density of medium should be lower than 12000kg/m³.

 

4. Structure Characteristic of WQ Series Sewage Submersible Pump

WQ series submersible sewage pump is equipped with status indicator and protection device to ensure for pump safe and reliable operating.

1). The unique cable airproof is adopted, avoid leakage of cable.

2).  Heat protector in stator assure of operating life of the motor.

3).  The pump adopts outer recycling cooling design with motor power more than 18.5kw, which can keep the pump operating safely under the lowest water level.

4).  A floating switch is installed at the bottom of motor chamber to protect the mechanical seal in the motor side.

5).  The oil-water probe is installed at the up end of the oil chamber between pump and motor that can protect the mechanical seal in the side. If leakage occurs, the system will signalize and start protection.

6).  Adopt perfect mechanical seal, the sealing material adopt tungsten carbide, silicon carbide and hard metal alloy, which can prevent the water from entering into the motor, and keep the operating reliable and safety.

7).  The auxiliary impeller can balance the pressure outside of the mechanical seal, prevent the water entering into the oil chamber and prolong the life of the motor.

8).  Unique impeller design, wide passage allow large solid and long fiber passing through freely, it features non-clog, convolve-proof and good passing ability.

9).  The changeable wearing ring is installed between the impeller and the volute to keep the optimum operation conditions.

 

5. Impeller Design Characteristics of WQ Series Sewage Submersible Pump

For the feculence pass freely, it must be widen the flowing passage of impeller, for the big pump, can used for double-vane, or three-vane, for the small pump, it used for single(double) flowing passage, like a bent pipe has same section, it has a good passing characteristic, avoid stop, convolve caused by slowing current possibly. The especially flowing passage of impeller, cooperate with logical volute, made the paper, soft goods, garbage bag and other material in sewage can passing freely and the pump have no vibration in the course of running-in and load through the impeller balance between dynamic and static state.

 

WQ Series Sewage Submersible Pump

 

 

WQ Series Sewage Submersible Pump

  

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Which is the better option for a home water pump?
In case of pump failure, it's much easier to repair/replace a floor based pump plumbed with isolation valves and unions. I've replaced a few due to motor failures and flood damage. Arguably, the submersible pump wouldn't have suffered damage due to flooding. Another consideration is vertical pump height. A floor based pump has to draw a vacuum to induce water to flow up to the impeller. This limits the practical draw to between 25 and 30 ft. Much more than that height and the vacuum will exceed the vapor pressure of the the water, boiling it rather than pumping it. A special device can be used to boost the lift: an ejector is placed down the well. Water is pumped down to the ejector, which pulls additional water back up using the venturi effect. This method suffers from additional friction losses but has clear advantages. If you need to pump water up a well more than 20 feet vertical, you should consider a submersible pump, particularly if you are concerned about the possibility of the water table lowering.
Q:Where should I buy my new water pump?
None of the above, you want to get a delco part so call around. Autozone uses garbage parts so I would stay away from there. If you live near Phoenix I can suggest many places for you.
Q:where is temperture sensor of water pump?
Look in the maintenance manual in the glove box
Q:30kW what is the flow rate of the pump?
Without a lift, how can I calculate it for you?
Q:does aquarium pump go in water?
If you mean an air pump, no, it doesn't go in the water.
Q:water pump failure? or what?
I would check the thermostat. But you don't check it like the first answer indicates. Pull the thermostat out. Look at it if it is open it is bad. If it is closed put it in a pot of boiling water. If it does not move it is bad. This may seam like allot to go through but if it is not the thermostat your only out the cost of a new gasket. And you know for sure. If there is nothing wrong with the thermostat , than you aren't getting circulation. A few causes would be: Cooling system clogged water pump bad internal leak or external leak. If you have a leak the system can't build pressure.It will take a long time to warm up and or it will make you think it is over heating but it will only be a leak. It will also run hot. NEVER OPEN A RADIATOR CAP WHEN THE ENGINE IS HOT. YOU WILL BE GOING TO THE HOSPITAL TO HAVE YOUR BURNS TREATED!!!
Q:Do I need a water pump or is it something else wrong with my car?
Another possibility: The Upper intake manifold could be leaking coolant into the engine. In other words, it is not an external leak. The leak is caused by the EGR valve actually melting the manifold, right by a coolant passage in the intake manifold. Again, check for milky oil (it'll look like dark butterscotch pudding....no really!). But be careful....a shady mechanic may tell you its a blown head gasket and it could just be this problem. If at all possible, have it checked out. If he says Blown head gasket, ask him to remove the upper intake only so that you can see it....there will be coolant and milky oil all over the top of the lower intake manifold if it's the upper intake problem. If it's diagnosed as a blown head gasket, this coolant/oil WON'T be there. The repair involves replacing the upper intake manifold completely, not just a gasket. Good Luck....
Q:Physics help with water pump?
It is known that 1 hp = 746 watts, so 0.13 hp = 97 watts = 97 Joules/s The amount of work to lift 1 kg water a vertical distance = 30.23 m = mgh mgh = (1)(9.81)(30.23) = 296.6 J no. of seconds in 2.20 hr = (2.2)(3600) = 7920 s total work output of a 0.13 hp pump in 2.2 hr if 100% efficient = (7920)(97) = 768,240 J no of kg lifted by 100% efficient pump/motor in 2.2 hr = 768,240/296.6 = 2590 kg ANS
Q:Location of fresh water pump on early 90's Jayco 2500 bumper pull trailer.?
having had many travel trailers the water pump is usually in a cabinet or under a bed or couch with a lot of plastic water lines near where you screw the water hose into the side of the trailer. and they are usually a preset psi from the factory so that is usually nothing to have to worry about and most have an on off switch located in the traier by the kitchen sink.And if the hot water heater is no good look into a tankless water heater it will save you money in the long run but initially you have to have a vent installed up through the roof away from a roof air vent. Another suggestion everytime you move a travel trailer they get the crap pounded out of them and someone needs to go up on the roof with a ladder and/or a plank that goes across the width so there is no weight standing on a roof to make dents or pop seams. Use some plastic stuff like plasticote available at wal mart after you move the trailer and set it up go up and make sure to double coat any of the seams that need it. I crank the heat up inside the trailer and do a double coat the heat rising will put a skin on the plasticote in a few hours instead of 12 or more. and the double coat gets any cracks missed the first time around. After that check it once a year if the trailer stays there.
Q:4--6 inch deep well pump head? How much per hour out of water?.
Deep well pump head is based on how much the impeller, impeller 200QJ section is 11 meters lift, 250QJ is about 17 meters, 300 meters high lift, 4 inch flow in 80 to 100 tons per hour, 6 inch flow in 150 to 200 tons per hour
Our wide range of products may be applied to numerous industries including to water irrigation, construction, municipal services and more. With four production bases, our facilities cover an area of approximately 210,000 square meters. Altogether, our group has 6 wholly-owned subsidiaries, 12 sales companies and more than 200 offices throughout the world.

1. Manufacturer Overview

Location Shanghai,China
Year Established 1993
Annual Output Value Above US$100 Million
Main Markets 11.11% North America
11.11% South America
11.11% Eastern Europe
11.11% Southeast Asia
11.11% Oceania
11.11% Mid East
11.11% Eastern Asia
11.11% Western Europe
Company Certifications ISO9001:2000;ISO14001:2004

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Shanghai
Export Percentage 11% - 20%
No.of Employees in Trade Department 6-10 People
Language Spoken: English, Chinese
b)Factory Information  
Factory Size: 30,000-50,000 square meters
No. of Production Lines Above 10
Contract Manufacturing OEM Service Offered Design Service Offered
Product Price Range High and/or Average