• WQ Series Vertical Sewage Submersible Pump System 1
  • WQ Series Vertical Sewage Submersible Pump System 2
  • WQ Series Vertical Sewage Submersible Pump System 3
WQ Series Vertical Sewage Submersible Pump

WQ Series Vertical Sewage Submersible Pump

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
2000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Product Description:

All details for WQ Series Sewage Submersible Pump:

 

1. Product Introduction of WQ series Sewage Submersible Pump

WQ series submersible sewage pump is mainly used for municipal work, industrial building, hotels, hospitals, civil air defense, mines, etc. It can be widely used in transfer waste water, rainwater and living water etc. which contains solid grains and various long fibers CNBM WQ series sewage submersible pump have many advantages, such as, hi-efficiency, circumvolution proof, blockage free, auto-coupling, hi-reliability and auto-control, etc.

 

2. Technical Performance of WQ series Sewage Submersible Pump

Discharge diameter: 50~600 mm

Capacity: 10~8000m³/h

Head: 5~60m

Power: 1.5~315kw

Diameter of pass solids: 20~145mm

 

3. Operation Condition of WQ Series Sewage Submersible Pump 

1). Rated Voltage: 380V(660V), Frequency: 50Hz, 3-phase AC.

2). Temperature of medium under 40ºC.

3). PH value: 4~10.

4). Volume ratio of solid in medium below 2%.

5). Density of medium should be lower than 12000kg/m³.

 

4. Structure Characteristic of WQ Series Sewage Submersible Pump

WQ series submersible sewage pump is equipped with status indicator and protection device to ensure for pump safe and reliable operating.

1). The unique cable airproof is adopted, avoid leakage of cable.

2).  Heat protector in stator assure of operating life of the motor.

3).  The pump adopts outer recycling cooling design with motor power more than 18.5kw, which can keep the pump operating safely under the lowest water level.

4).  A floating switch is installed at the bottom of motor chamber to protect the mechanical seal in the motor side.

5).  The oil-water probe is installed at the up end of the oil chamber between pump and motor that can protect the mechanical seal in the side. If leakage occurs, the system will signalize and start protection.

6).  Adopt perfect mechanical seal, the sealing material adopt tungsten carbide, silicon carbide and hard metal alloy, which can prevent the water from entering into the motor, and keep the operating reliable and safety.

7).  The auxiliary impeller can balance the pressure outside of the mechanical seal, prevent the water entering into the oil chamber and prolong the life of the motor.

8).  Unique impeller design, wide passage allow large solid and long fiber passing through freely, it features non-clog, convolve-proof and good passing ability.

9).  The changeable wearing ring is installed between the impeller and the volute to keep the optimum operation conditions.

 

5. Impeller Design Characteristics of WQ Series Sewage Submersible Pump

For the feculence pass freely, it must be widen the flowing passage of impeller, for the big pump, can used for double-vane, or three-vane, for the small pump, it used for single(double) flowing passage, like a bent pipe has same section, it has a good passing characteristic, avoid stop, convolve caused by slowing current possibly. The especially flowing passage of impeller, cooperate with logical volute, made the paper, soft goods, garbage bag and other material in sewage can passing freely and the pump have no vibration in the course of running-in and load through the impeller balance between dynamic and static state.

 

6. FAQ

1). Can I get trained on CNBM products?

Yes, we provide training courses in our factory (products, general and specific pump technology, hydraulics, and practical applications). Please consult your sales manager or get in touch with our headquarters for more information.

2). Are your pumps cheaper than those of your competitors?

CNBM aims to give its customers the highest standards of quality and service and delivery times, all at a reasonable price.

3). How long is your warranty?

Unless otherwise expressly authorized in writing, by specifying a longer period or different conditions, CNBM states that, for a period of twelve (12) months from delivery date, all Products supplied are free from defects in materials and workmanship, and conform to the applicable specifications. Either the delivery documentation or the invoice must be provided to prove delivery date. In absence of such documents, the production date appearing on the product label may suffice。

(4)Can your pumps mount Eff.1 motors

Currently, only on request though this will shortly be a CNBM standard.

(5)Are your pumps protected against dry running?

No, unprotected centrifugal pumps are not generally designed for dry running. It is important to give us or your dealer as much information as possible about the system in which the pump is used. Inlet pressure, the type of liquid to be pumped, together with relative density, viscosity and temperature, for example, are required in order to allow CNBM to recommend the right pump with the right gaskets for a long operating lifetime.

(6)How can I get trained on CNBM products?

Yes, we provide training courses in our factory (products, general and specific pump technology, hydraulics, and practical applications). Please consult your sales manager or get in touch with our headquarters for more information.

WQ Series Vertical Sewage Submersible Pump

WQ Series Vertical Sewage Submersible Pump




Q:How many concrete pump tube diameter
The pump tubing diameter is 125MM general concrete or mortar pump tube diameter is 80MM fine stone
Q:Does the reservoir water heater press the booster pump (high marks)?
If insufficient pressure really, adding an automatic booster pump in the water inlet, is feasible. Home booster pump, a basic model, to sell the place to ask the next to know, generally 200 yuan or so, traffic 0.3-1.8, 90~150 watts on it. Do not buy too large, too much power, the water will also be too large, but the water heater will not be used.
Q:What does "efficiency" mean in a water pump catalog?
Pump efficiency: the ratio of the effective power and the pump shaft power
Q:What is the series of pumps? What is the difference between a unipolar and a multilevel? What is the meaning of each "first class"?
You're talking about a centrifugal pump. His series says the number of slices of the impeller (excluding the wheel, that is, the wheel)
Q:Fire hydrant pump button, under what circumstances do not need to install?
There are four things to do:Fire hydrant button to meet the requirements of national standards.In addition to pumping, it can show the location of fire.
Q:Metering pumps related matters
2) change the metering pump diaphragmTrouble is often encountered when the old diaphragm is removed. Provide some additional advice on how to remove the old diaphragm.After in the pump head loose, remove the pump head before the stroke length adjustment to the 10% position. To ensure that the electromagnetic axis has sufficient pressure to maintain its connection firmly, so that you can unscrew the diaphragm.The pull end torque from the Jack out of the screw. Seize the liquid counter clockwise rotation. There is a slight resistance that can unscrew the diaphragm.Chemical 3 measurement may end in fluid crystallization, resulting in a one-way valve ball and seat valve does not work.In the end inhalation metering pump may have a gas leak. Hydraulic end suction side connector may lack O ring or suction valve connection loose.3) flow monitoring and measurement of a high viscosity medium, in the process of liquid delivery received a flow failure signal, how can we solve this problem?Move the hydraulic end by loosening the 4 pump head screws. Rotating stroke length to 10%, and seize the hydraulic end, and then slide out of the screw hole, then the screws do not touch them, but still control the back and diaphragm. Then rotate the component counter clockwise, with a slight resistance, and the diaphragm will loosen from the electromagnetic axis. If the diaphragm is not loose, use some grease on the contact surfaces of the diaphragm and the electromagnetic shaft. After a few minutes, gently tap the diaphragm with a small plastic hammer. Then proceed again in accordance with the above description.
Q:Common failure treatment of piston pump
1) overflow valve regulation is too high, overload after the pump2) the overflow valve spool is blocked, the central hole of the valve core is blocked or the overflow valve is blocked by a damping hole, and the overflow is not overflow3) pump outlet one-way valve installed or spool blocked and stuffy pump4) motor fault x091) adjust the relief valve pressure value2) repair valve boring3) overhaul check valve4) overhaul or replace the motor
Q:Why should the pump be closed when the centrifugal pump is started?
Therefore to close the outlet valve, the pump during starting output water, the minimum pump power, when the pump reaches the rated speed, slowly open the outlet valve, gradually increase the flow of water, the motor current is gradually increased to the rated current.
Q:What is the difference between an air pump and a water pump?
Pump performance of technical parameters are flow, suction, lift, shaft power, water power, efficiency, etc.; according to the different principles of work can be divided into volume pumps, vane pumps and other types. Displacement pump is to use its studio volume changes to transfer energy; vane pump is to use the rotating blade and water interaction to transfer energy, there are centrifugal pumps, axial flow pumps and mixed flow pumps and other types.
Q:How to distinguish the flow and displacement in the hydraulic pump? What's the difference between the two?
If you're allowed to spend a minute, you can do it 20 times a minute, and that is, the amount of water you sprinkle at a time (1000) is *20.1000 (ML) *20=20000 ml =20 liters, this is the flow,Here is a formula for you to see,Pump displacement * pump speed = flow,

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products