WQ Vertical Sewage Centrifugal Submersible Water Pumps
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 100 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
1. Specification For WQ Submersible Sewage Centrifugal Pump1) CE,GS,ROHS,ISO9001.CC 2. Product Introduction for WQ Submersible Sewage Centrifugal Pump. 3. Working Condition of WQ Submersible Sewage Centrifugal Pump. 4. FAQ for WQ Submersible Sewage Centrifugal Pump |
- Q: You'd better point out the details.... There are 2 best ways of experience and formulaCan you say a simple point, such as multi-stage pump, when the pump is higher than the motor, 30 wire is the next mouth how to do?
- For the first time, the pump and motor were placed on the base and not fastened (Cu Zhaozheng);Second times, the pump and motor have been tightened, the inlet and outlet flange bolts are not fastened;Third times, the pump runs 24 hours later.
- Q: How does the centrifugal pump pump and cut the pump?
- Turn on the motor, observe the motor current, turn from high to low, observe the pump outlet pressure, and the pressure rise;Slowly open the outlet valve, so that the pressure drop slowly, the current slowly rising to the stable, the outlet valve to the maximum;Check the pump operation, stuffing box leakage, current, whether or not the rated current, motor, bearing temperature is normal, whether or not abnormal sound.
- Q: What is the dry running protector of screw pump? What's the principle and function? Thank you
- When the temperature reaches a certain value, the signal is transmitted to the electric control box through a dry running protector, and the electric control box is used to stop the screw pump so as to protect the screw pump.
- Q: How many millimeters is the diameter of the water outlet of the four inch pump?
- If it is a centrifugal pump, the nominal diameter of the outlet is less than 4 inches, there is a conical short tube to enlarge the standard 4 inch outlet flange, from here, is the standard 4 inch flange connection.
- Q: If you use an ordinary 15W submersible pump, put it in the tank, if the leakage, the fish will hang it?
- Submersible pump even if it really leakage, it will not cause the fish electric shock. The so-called leakage is the submersible pump wire or shell broken, live parts and water contact, the most extreme test is a fire line directly into the fish tank
- Q: What are the starting and stopping procedures for centrifugal pumps?
- Operation method and operation procedure of self-priming centrifugal pumpClick number: 440 release time: 2011-7-24Centrifugal pump method, centrifugal pump operation steps, centrifugal pump use steps
- Q: What does "efficiency" mean in a water pump catalog?
- Pump efficiency: the ratio of the effective power and the pump shaft power
- Q: Why is the flow of the pump too small will occur cavitation phenomenon?
- Throttling regulation is to change the opening of the valve to change the flow of the pump, that is to say, to change the characteristic curve of the pipeline. The commonly used to regulate the flow of exports, because the entrance throttle makes reduce the inlet pressure caused by cavitation danger.
- Q: The working principle of magnetic pump
- Structure characteristics1. permanent magnetPermanent magnet operating temperature range is made of rare earth permanent magnet wide (-45 - 400 DEG C), high coercivity, magnetic anisotropy direction is very good, also won't happen in the same demagnetization phenomenon when is close, is a good source of the magnetic field.2. isolation sleeveIn the metal isolation, isolation sets in a sinusoidal alternating magnetic field, in a cross section perpendicular to the direction of magnetic field lines induced eddy current and converted into heat. Eddy current expression is:. The Pe - K constant; eddy current; rated speed of N - T - pump; magnetic drive torque; F - the pressure inside the sleeve; D sleeve diameter; a material resistivity; and the tensile strength. When the pump design is completed, N, T is the given conditions, to reduce eddy current only from F, D, and so on. Non metallic materials with high resistivity and high strength production isolation, in reducing the eddy current effect is very obvious.
- Q: Attention should be paid to the use of pumps?
- To carefully check whether there is a crack impeller, impeller fixed in the bearings are loose, if there are cracks and loose, hungry phenomenon should be promptly repaired, if the pump impeller above the soil should also be cleaned
Send your message to us
WQ Vertical Sewage Centrifugal Submersible Water Pumps
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 100 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords