SS Chemical Pumps for Chemical Industry
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 10000 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
1.Specifications of SS Chemical Pumps• Industrial chemical pump
• For corrosion liquid
• Easy maintenance,High efficiency
• OEM order is accepted
• Good quality and service
2.Main features of SS Chemical Pumps
Chlor-alkali industry: lye, electrolyte, refined salt water of ion film caustic soda, chlorine solution, sodium hypochlorite, hydrochloric acid, sulfuric acid.
Iron and steel industry: electroplating, pickling, etc;
Paper-making industry: agents, bleaching liquid, sewage, etc;
3.Specification of SS Chemical Pumps
model | traffic | head | speed | power | CAL mm | |
suction | discharge | |||||
50-32-125 | 12.5 | 20 | 2900 | 2.2 | 50 | 32 |
6.3 | 5 | 1450 | 0.55 | 50 | 32 | |
50-32-160 | 12.5 | 32 | 2900 | 3 | 50 | 32 |
6.3 | 8 | 1450 | 0.55 | 50 | 32 | |
50-32-200 | 12.5 | 50 | 2900 | 0.5 | 50 | 32 |
6.3 | 12.5 | 1450 | 0.75 | 50 | 32 | |
50-32-250 | 12.5 | 80 | 2900 | 11 | 50 | 32 |
6.3 | 20 | 1450 | 1.5 | 50 | 32 | |
65-50-125 | 25 | 20 | 2900 | 3 | 65 | 50 |
12.5 | 5 | 1450 | 0.55 | 65 | 50 | |
65-50-160 | 25 | 32 | 2900 | 5.5 | 65 | 50 |
12.5 | 8 | 1450 | 0.75 | 65 | 50 | |
65-40-200 | 25 | 50 | 2900 | 7.5 | 65 | 40 |
12.5 | 12.5 | 1450 | 1.1 | 65 | 40 | |
65-40-250 | 25 | 80 | 2900 | 15 | 65 | 40 |
12.5 | 20 | 1450 | 2.2 | 65 | 40 | |
65-40-315 | 25 | 125 | 2900 | 30 | 65 | 40 |
4.FAQ
① What is your product range?
Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage
pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe
water pump, boiler water pump, etc.
② Are you a manufacturer?
Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.
③ What information should I let you know if I want to get a quotation?
Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also
provide the pump model you are using now, price will be calculated as per the pump model, if not, we will recommend relevant product for reference.
- Q:Household automatic booster pump, how much pressure to work automatically, the water pressure and how many kilograms?
- Household automatic booster pump is not started by pressure, it is induced water pump, that is boiled water faucet
- Q:A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
- According to the water quantity form fire flow water supply system fire safety in high-rise building fire hydrant pump lift is 10L/s, accurate algorithm is to say after a simple calculation with each indoor hydrant flow is two 5L/s bolt so to get the most unfavorable point for the calculation unit to calculate the minimum requirements, with the most unfavorable point suppository pressure specifications 0.07MPa, partial loss of the most unfavorable line and the line (according to the equivalent length) and loss (according to the material resistance coefficient), and finally the pump head loss of gravity difference. But we just calculate the construction elevation difference multiplied by 110% to 120% to determine the head {there is a need to know is: conversion head (m), (kg) and MPa kg 1MPa=10 kg = 100m is the vertical water column on unit area pressure conversion
- Q:Bolus dosage of infusion pumpWhat is the purpose of the pill dose control in the special safety standard for infusion pumps? If the risk is not properly controlled, what is the degree of risk? And how can the open infusion pump be used in this regard?
- Four) release bolus dosage method can use automatic release and manual release two ways, the key is to alarm after the infusion must be stopped(five) any kind of pill dose release are not restricted to replace the pill. The total dose limit for in pipe blockage after pill agglomeration process will remove blocking accident, this time will be the rapid infusion of pill dose concentration into the patient's blood, if the total dose pill does not get test and limit, rapid infusion of this accident it may have unimaginable consequences.(six) supplies open type infusion pump overflow on the domestic market for pill characteristic parameters of consumables simply without testing and limitation. Therefore, the risk of accidental pill has become one of the residual risk of open type infusion pump supplies the most deadly.
- Q:What does "anti pump" mean in pump operation?
- The working process of the main oil cylinder pushing back and forth against the pump when the S valve (C valve or valve or gate valve skirt) reverse swing, so the piston suction concrete cylinder is in the ash conveying pipe is exactly opposite is the pump suction pump (hopper is concrete and push into the hopper, the desizing)
- Q:Suction stroke and lift of water pump
- Lift pump lift pump can lift refers to the height, usually expressed in H, the unit is m. centrifugal pump lift to the impeller center line, divided by two parts. The vertical height from the pump impeller centerline to the water surface, the water pump to suck water up to the height, called water head, referred to as suction pump impeller; from the center line to the vertical height of the water tank, the water pump can put pressure on the height, called water pressure head, referred to as the pressure. The pump head = + suction head pressure water head should be pointed out that the nameplate marked head refers to the pump itself can produce lift, it is not with the pipe flow friction resistance caused by the loss of lift. In the selection of water pump, attention can not be ignored. Otherwise, will be pumping Sheung Shui.
- Q:What is the lift of diaphragm pump?
- Hello, pneumatic diaphragm pump head is liquid, the energy obtained through the pump is called the head, it is related to the flow rate and pump speed, liquid density.Please adopt.
- Q:What are the basic technical parameters of the pump?
- Two, pump head H head is the unit weight of the liquid pump pumping from the inlet of the pump (pump inlet flange) to the outlet of the pump (pump outlet flange) energy value. Effective energy is a Newtonian liquid through the pump unit is obtained. The N m/N=m, the height of liquid column pumping liquid. Habits referred to as meters. Three, the pump speed is n RPM pump unit time revolutions, represented by the symbol n, the unit is r/min. four, the pump NPSH NPSH NPSH is also called net positive suction head, said main parameters of cavitation performance. Cavitation has been used a h power of five, the power of the pump. And the efficiency of the pump is usually refers to the input power, which is the prime mover on the pump shaft power, it is also known as the shaft power, denoted by P;
- Q:Pump unloading in hydraulic transmission,
- Unloading is pumping oil directly back to the tank, the pressure is very low, energy saving
- Q:What are the starting and stopping procedures for centrifugal pumps?
- The use of centrifugal pump can be divided into three steps, namely, start, run, stop.Start: you should do the following preparation before starting:(1) check the water pump equipment in good condition.(2) the bearings are filled with oil, the oil level is normal, and the oil quality is qualified(3) all the inlet valves of the centrifugal pump are opened.(4) pump water injection or vacuum pump diversion (except for flow), open the vent valve exhaust.(5) check the leakage of shaft seal. It is advisable to fill the seal with a little drop of water.(6) the motor rotates in the right direction.
- Q:What is the pumping property of concrete?
- Pumping capacity means that fresh concrete can be transported by concrete pump, and concrete construction can be carried out with high efficiency. 'pumping' is a qualitative statement
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
SS Chemical Pumps for Chemical Industry
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 10000 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Hot Searches
Related keywords