• Oil-filled Submersible Pump System 1
Oil-filled Submersible Pump

Oil-filled Submersible Pump

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Product introduction:
QYOil-filled submersible pump consists of pump, mechanical seal and motor. Pump is at the bottom part of pump, which is adopted centrifugal impeller. Motor which is triphase is at the upper part of pump and seal is used where pump and motor combine, which is a kind of double end mechanical seal"0"rings are applied to all static joints.
Axial flow impeller design can meet customer demand for big flow

Application:
This series pump because of wide range of flow and head, is extensively used for electrical irrigation, forest water spraying, pumping water from well, water tower deliver and urban construction water supply and discharge for farms, villages, industrial and mining enterprise.

Work Conditions:
The pump can work properly and continuously under following operational conditions:
1.Medium is not corrosive. Sand contents should be max. 0.10% by volume and granular size should be max.0.20mm.
2.Medium temperature shouldn’t be over 40°C and PH should be 6.5-8.5.
3.The pumps should be operated within rated head.
4.The pumps should be fully submerged into water with depth of less than 3m and max. The pump should be min. 0.5m over (he water bottom and not be inserted into sludge.
5.Power frequency should be 50Hz,three-phase vollage 380V.and voltage fluctuation should be 0.9-1.1 limes than the rated.


Q:Double floor sewage pump circuit diagram of a small problem
Question 3 when the water level is low, when the 1KA is connected, the pump will run depending on where your SS selector switch is located. Its left and right position, running pump and standby pump definition is different, left position is 1#, running 2# standby, right position is 2# running, 1# standby. Only inIn case the high level switch 2KA is connected, the standby pump may work at the same time.
Q:Bolus dosage of infusion pumpWhat is the purpose of the pill dose control in the special safety standard for infusion pumps? If the risk is not properly controlled, what is the degree of risk? And how can the open infusion pump be used in this regard?
Four) release bolus dosage method can use automatic release and manual release two ways, the key is to alarm after the infusion must be stopped(five) any kind of pill dose release are not restricted to replace the pill. The total dose limit for in pipe blockage after pill agglomeration process will remove blocking accident, this time will be the rapid infusion of pill dose concentration into the patient's blood, if the total dose pill does not get test and limit, rapid infusion of this accident it may have unimaginable consequences.(six) supplies open type infusion pump overflow on the domestic market for pill characteristic parameters of consumables simply without testing and limitation. Therefore, the risk of accidental pill has become one of the residual risk of open type infusion pump supplies the most deadly.
Q:How is the pump level of submersible sewage pump determined?
Below the top elevation of the sump, 200 is the warning water levelBut note: 1, the effective volume of the sump meets the requirements. 2, the pump should have enough submerged water level
Q:Why can't the centrifugal pump pump the vacuum?
Condition:The pump shell must be filled with liquid under certain installation height and running without leakage.What is the phenomenon of centrifugal pump? What harm does it have? How to eliminate?)
Q:Why does the centrifugal pump close the pressure to start?
The motor power is selected according to the rated flow of shaft power points plus 15 to 25%, if the outlet valve is fully open to start, the pump flow may deviate from the amount of fixed lot, pump efficiency also reduces a lot, resulting in shaft power greater than the motor power caused by tripping even burned electric machine.
Q:What is the relationship between the minimum suction vacuum of a pump and the required cavitation?
Suction is allowed to pump the vacuum from the distance from the inlet, which is part of the field installation.The manufacturer of cavitation allowance is closely related to the design and process of pump. Estimation formula: cavitation allowance =10.33 meters - allow suction of -0.5 meters (safety).
Q:What's the meaning of the pump head in the water pump, please advise, thank you
The pump head of the centrifugal pump refers to the shell that contains the impeller and impeller, and also includes the shaft part that drives the impeller. It can be used as the part of the motor and shaft coupling and the base.
Q:What are the meanings of the vacuum pump, the front pump and the main pump?
The main pump and the front pump with the general vacuum unitThe front pump can be understood as a mechanical pump. It can be used by itself, but the pumping rate or the vacuum can not meet the requirements. In this case, we add a booster pump
Q:I would like to ask, constant pressure pump set pressure 20Mpa, the actual load is 15Mpa, then the constant pressure pump outlet pressure? If it is 20Mpa, then where is the loss of 5Mpa? If 15Mpa, the constant pressure pump 20Mpa how to understand? In addition, the constant pressure pump pressure is defined when the flow began to reduce the point, or a sharp drop in flow after the point?
Constant pressure pump is pressure maintained at the set pressure, flow control valve according to the order, there is pressure to set, after the pump displacement is reduced, as for how to reduce emissions, to see how much you need to flow.
Q:Is the flow meter in front of the pump or after the pump?
After the pump, the reasons are as follows, before the pump, you pump fluid through the pump will produce negative pressure in front of the pump, negative pressure on the flow of the life of the impact, the pump will not, Suzhou first Chi meter

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords