Single Stage Horizontal Corrosive Chemical Pump
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 10000 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
1.Specifications of Single Stage Horizontal Corrosive Chemical Pump• Industrial chemical pump
• For corrosion liquid
• Easy maintenance,High efficiency
• OEM order is accepted
• Good quality and service
2.Main features of Single Stage Horizontal Corrosive Chemical Pump
Chlor-alkali industry: lye, electrolyte, refined salt water of ion film caustic soda, chlorine solution, sodium hypochlorite, hydrochloric acid, sulfuric acid.
Iron and steel industry: electroplating, pickling, etc;
Paper-making industry: agents, bleaching liquid, sewage, etc;
3.Specification of Single Stage Horizontal Corrosive Chemical Pump
Model | Capacity | Head | Speed | NPSHr | Efficiency | Power(N)(kW) | Weight | |
Q(m3/h) | H (m) | n(rpm) | r(m) | η (%) | Shaft power | Motor power | w(Kg) | |
IH50-32-125 | 7.5 | 22 | 2900 | 2 | 47 | 0.96 | 2.2 | 34 |
12.5 | 20 | 2 | 60 | 1.13 | ||||
15 | 18.5 | 2.5 | 60 | 1.26 | ||||
IH50-32-125A | 6.7 | 17.5 | 2900 | 2 | 45 | 0.71 | 1.5 | 33 |
11.2 | 16 | 2 | 58 | 0.84 | ||||
13.5 | 14.7 | 2.5 | 58 | 0.93 | ||||
IH50-32-160 | 7.5 | 34.3 | 2900 | 2 | 44 | 1.59 | 3 | 39 |
12.5 | 32 | 2 | 54 | 2.02 | ||||
15 | 29.6 | 2.5 | 56 | 2.16 | ||||
IH50-32-160A | 7 | 30 | 2900 | 2 | 42 | 1.36 | 2.2 | 38 |
11.7 | 28 | 2 | 52 | 1.71 | ||||
14 | 26 | 2.5 | 54 | 1.83 | ||||
IH50-32-160B | 6 | 25.8 | 2900 | 2 | 40 | 1.05 | 1.5 | 37 |
10 | 23 | 2 | 50 | 1.25 | ||||
12 | 21 | 2.5 | 52 | 1.32 | ||||
IH50-32-200 | 7.5 | 52.5 | 2900 | 2 | 38 | 2.82 | 5.5 | 43 |
12.5 | 50 | 2 | 48 | 3.54 | ||||
15 | 48 | 2.5 | 51 | 3.95 | ||||
IH50-32-200A | 7 | 45.3 | 2900 | 2 | 37 | 2.33 | 4 | 42 |
11.7 | 44 | 2 | 46 | 3.05 | ||||
14 | 41.5 | 2.5 | 49.5 | 3.2 | ||||
IH50-32-200B | 6.5 | 39.6 | 2900 | 2 | 36 | 1.95 | 3 | 41 |
10.8 | 37.5 | 2 | 45.5 | 2.42 | ||||
13 | 36 | 2.5 | 48.5 | 2.63 | ||||
IH50-32-250 | 7.5 | 82 | 2900 | 2 | 28.5 | 5.87 | 11 | 75 |
12.5 | 80 | 2 | 38 | 7.16 | ||||
15 | 78.5 | 2.5 | 41 | 7.83 | ||||
IH50-32-250A | 7 | 72 | 2900 | 2 | 28 | 4.9 | 7.5 | 74 |
11.7 | 70 | 2 | 37.5 | 5.95 | ||||
14 | 68.5 | 2.5 | 40 | 6.53 | ||||
IH50-32-250B | 6 | 61.5 | 2900 | 2 | 27.5 | 3.65 | 5.5 | 73 |
10 | 60 | 2 | 36.5 | 4.48 | ||||
12 | 58.5 | 2.5 | 39 | 4.9 |
4.FAQ
① What is your product range?
Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage
pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe
water pump, boiler water pump, etc.
② Are you a manufacturer?
Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.
③ What information should I let you know if I want to get a quotation?
Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also
provide the pump model you are using now, price will be calculated as per the pump model, if not, we will recommend relevant product for reference.
- Q: Must the water pump in the tank be all soaked in water?
- Usually you have to soak it all in the water. If you don't want to put it in the water, you can buy an amphibious pump. At most, you can expose it
- Q: What are the characteristics of a pipe shield pump?
- Two, reverse circulation type of shielding pump, its bearings, lubrication, cooling and motor cooling fluid flow direction and the basic type is the opposite. The main characteristic of reverse circulation pump is that it is not easy to generate cavitation. It is suitable for conveying liquid which is easy to vaporize. Sometimes it is also called "easy to vaporize" type. Three, high temperature medium temperature of up to 450 degrees. The cooling water jacket is usually added outside the shielding motor, and a cooling sleeve is added to the outer circulation pipe to cool the high temperature circulating liquid to reduce the temperature of the motor and the bearing. In the case of less power, some manufacturers do not use cooling liquid, but the outside of the motor is equipped with fins and the special winding to adapt to the working conditions, the use of temperature generally can not exceed 400 degrees.
- Q: Advantages and disadvantages of centrifugal pumps?
- The centrifugal pump has no valve, so it is suitable for conveying suspended liquid, and the special design can also transport large solid suspensionThe pump can be made of chemical resistant material, which is suitable for conveying corrosive solution.The utility model has the advantages of simple structure, few parts, little failures, durability, low maintenance cost, convenient management and reliable work.The output can be adjusted even by the discharge valve fully closed, there is no danger of infinite rising pressure head.The liquid is transferred to a large quantity. And the pressure head does not require large, most suitable for centrifugal pump.
- Q: Brief description of centrifugal pump on / off operation
- (3) check whether the turning rotor is easy and flexible, check the pump body is clang or friction sound.(4) the protective cover is installed, and the shield contact.(5) clean the pump frame and do a good job of sanitation.(6) open the inlet valve, make the liquid full of pump body, open the vent valve, clean the air and close it. If the hot oil pump, it is not allowed to open the air valve exhaust, to prevent hot oil channeling spontaneous combustion, if there is a dedicated vent pipes and tanks, you can vent the pipe line air and cold oil.(7) the hot oil pump should be preheated slowly before starting. Especially in winter, the pump body and the pipe should be preheated at the same time, so that the temperature difference between the pump body and the conveying medium is below 50 centigrade.(8) the oil must be sufficiently dehydrated before being introduced into the oil pump.
- Q: What's the difference between non negative pressure and variable frequency water pump?
- No negative pressure is superposed pressure intelligent frequency conversion equipment, pump frequency operation is no negative pressure difference, and the variable frequency pump, variable frequency pump is advanced municipal tap water tank or pool, pump from the tank or pond water pressure to set pressure to the pressure water supply, and no negative pressure directly from water the municipal pipeline, using the original municipal 2~3 kilograms of pressure
- Q: What is the function of the heating pump system for the water pump design?
- As the feed water temperature is higher, before starting, if not enough to warm the pump, the pump body temperature is uneven, there is a hot, cool phenomenon. The upper part is inflated and the lower part is inflated"
- Q: Metering pumps related matters
- 2) change the metering pump diaphragmTrouble is often encountered when the old diaphragm is removed. Provide some additional advice on how to remove the old diaphragm.After in the pump head loose, remove the pump head before the stroke length adjustment to the 10% position. To ensure that the electromagnetic axis has sufficient pressure to maintain its connection firmly, so that you can unscrew the diaphragm.The pull end torque from the Jack out of the screw. Seize the liquid counter clockwise rotation. There is a slight resistance that can unscrew the diaphragm.Chemical 3 measurement may end in fluid crystallization, resulting in a one-way valve ball and seat valve does not work.In the end inhalation metering pump may have a gas leak. Hydraulic end suction side connector may lack O ring or suction valve connection loose.3) flow monitoring and measurement of a high viscosity medium, in the process of liquid delivery received a flow failure signal, how can we solve this problem?Move the hydraulic end by loosening the 4 pump head screws. Rotating stroke length to 10%, and seize the hydraulic end, and then slide out of the screw hole, then the screws do not touch them, but still control the back and diaphragm. Then rotate the component counter clockwise, with a slight resistance, and the diaphragm will loosen from the electromagnetic axis. If the diaphragm is not loose, use some grease on the contact surfaces of the diaphragm and the electromagnetic shaft. After a few minutes, gently tap the diaphragm with a small plastic hammer. Then proceed again in accordance with the above description.
- Q: Because the water pressure of the booster pump is not enough, it can not work automatically. It can only be operated by hand. It is inconvenient to use.
- The worst case is that the pump is not automatic when it leaves the factory, and no one can say whose product is 100%.But there may be automatic control of this piece, not debugging (this depends on the specific product manual or manufacturer)
- Q: How to calculate the motor power of metering pump?
- The total mechanical power and hydraulic power, divided by the overall efficiency of pump, and the pump head and the utilization rate of pump mechanical efficiency, and then multiplied by 1.1 times (API675), you can get a metering pump motor need more power.
- Q: How long does the fine stone pump need maintenance? What should I pay attention to?
- Check the line from the relief valve to the cylinder inlet to ensure that there is no external drainage or deformation due to impact and wear and that the connections are complete and fully tightened. - replace any damaged pipe immediately. - change the original settings strictly: all adjustments and calibrations can only be done by professionals. - no fucks hydraulic components, otherwise manufacturers on product warranties and liability shall not be responsible for. A warning because the hydraulic oil can reach very high temperature, there is the danger of burns, so open pipe fittings should take appropriate protective measures. Any replacement parts must conform to the level specified by the manufacturer. 8.2 check lubrication grease pump in oil at any time to ensure adequate and clean the lubrication pipeline joints without overflow phenomenon. Check the lubrication of the running parts at any time, and find the parts which lack oil, and check them immediately to prevent accidents. - check that the centralized lubrication system is effective daily. When the grease pump is empty, the grease added is often not easy to pump out because of the bubble. In this case, open the outlet of the pump, run the grease pump until the grease is re flowing, and then connect the pipe
Send your message to us
Single Stage Horizontal Corrosive Chemical Pump
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 10000 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords