Boiler Feed Centrifugal Multistage Water Supply Pump with High Pressure

Ref Price:
Loading Port:
Payment Terms:
Min Order Qty:
1 set
Supply Capability:
100000 set/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

  Boiler Feed Centrifugal Multistage Water Supply Pump with High Pressure

1.Structure of  Boiler Feed Centrifugal Multistage Water Supply Pump Description


Boiler Feed Centrifugal Multistage Water Pumpis used for transporting pure water (particles density shall be max.1%by volumeand granular size shall be max 0.1mm in dimeter) of the liquids with physical and chemical properties similar to pure water. Type MD pump is applied with wear resist material, especially suitable for mineral drainage. The particles density shall be max. 1.5% (Max. of the granular diameter is 0.5 mm).The liquid temperature ofD, MD pumps shall be lower than 80°C.


2.Main Features of the Boiler Feed Centrifugal Multistage Water Pump

• Compact structure, good appearance, low construction

Operation stably, same inlet and outlet

•Convenient installation and maintenance

Customized design is available, OEM and ODM are welcomed.

•Horizontally and vertically installation as different pipeline system

3. Boiler Feed Centrifugal Multistage Water Pump images

Boiler Feed Centrifugal Multistage Water Supply Pump with High Pressure

4. Boiler Feed Centrifugal Multistage Water Pump Specification



Multistage Pump

Multistage Pump

Horizontal Multistage Pump For Pure Water




Cast iron,Stainless steel






<=80°c< span="">


packing seal


Centrifugal Pump


Multistage Pump





Standard or Nonstandard





High Pressure


Hot and cold pure water

Outlet Diameter



6-1250 m3/h



Rotation Speed







High efficiency,Easy maintenance 



What is your product range?

Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage

pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe

water pump, boiler water pump, etc.

Are you a manufacturer?

Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.

What information should I let you know if I want to get a quotation?

Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also

provide the pump model you are using now, price will be calculated as per the pump model, if not, we willrecommend relevant product for reference.


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How do vacuum pumps and pumps work together?
The role of the check valve:"[the water pump impeller is not closed" refers to the pump suction pump before the water without water inlet pipe and water outlet pipe gas should be connected] is a connector, a connector, still can make the level surface, in order to prevent the water flow along the pipe, until it reaches the level of the flush, then increased check valve.
Q:What's the difference between non negative pressure and variable frequency water pump?
When peak water is used, the fluctuation of water pressure will be the same for customers! Because the key to the fluctuation of hydraulic pressure is the flow rate of the pump and the lift of the pump. As long as the flow of the selected pump is large enough, the tank is large enough, the lift head is suitable, and the pressure fluctuation is relatively small. And the selection of non negative pressure and frequency conversion pump group is not directly related. If the municipal tap water pressure and water sufficient (large enough diameter), the use of non negative pressure is better. If the municipal tap water pressure and water shortage, you can only use the frequency converter pump + water tank, no negative pressure can not be used.
Q:Fire pump and shower pump flow head selection, high resolution.
Selection of flow head of fire pump and spray pump:1, the volume is greater than 5000 is less than 10000, the minimum water consumption of indoor fire hydrant is 10L/s
Q:What is the function of a submersible pump?Do you have any knowledge about submersible pumps?.
Submersible pumpThe submersible pump is composed of a control cabinet, submersible cables, water pipes, submersible pumps and submersible motors.Submersible pump main application and scope of applicationIncluding mine rescue, construction, drainage, agricultural irrigation and drainage, industrial water recycling, urban and rural residents cited water supply, and even rescue, disaster relief and so on.Classification of submersible pumpsAs far as media is concerned, submersible pumps can be broadly divided into three categories: clean water submersible pumps, sewage submersible pumps, sea water submersible pumps (corrosive).
Q:What's the difference between a centrifugal pump and a centrifugal pump? What are they used for?
Centrifuges are generally used to classify liquids of different densities in liquids.
Q:What is pump suction work?
Pumping loss refers to the loss of work done by the piston of the engine in the pumping process compared with the theoretical cycle. Theoretical pump Qigong to remove the loss of pump gas after the actual pump qigong.
Q:What are the advantages and disadvantages of the pump control system and valve control system in the hydraulic system?
Large pump control valve controlled energy consumption at least 30% reason is that there are serious throttling loss of a throttle valve control system of severe fever but simple structure and low cost which is why now valve control system still occupy the main market reasons.Pump control system with complicated structure especially when serious nonlinear control unsymmetrical cylinder control effect is not ideal, but the biggest advantage is energy-saving and low fever America professor Monika points out that using the pump control system of hydraulic excavator energy efficiency compared with the valve control system can be improved by over 46% but costs are high. But in control, the three pump invented by Professor Quan LONG of China is a good solution. LZ can find the invention patent or find his paper on sage. It seems that there are three or four SCI about this pump
Q:Why adjust the centrifugal pump outlet valve can adjust the flow?
This method can be used to regulate flow. The advantage is that it is simple and easy to use and the disadvantage is that the throttle consumes energy
Q:What is cavitation, centrifugal pump cavitation phenomenon how to solve?
First, what is cavitation?:When the centrifugal pump shell has air, it produces less centrifugal force because the density of the air is much smaller than the density of the liquid. Thus, suction pressure at the entrance to the top of the tank liquid level and pump is bad enough to the liquid storage tank into the pump, the centrifugal pump self suction capability, the centrifugal pump can not transport liquid, this phenomenon is called "cavitation".When a liquid drops at a certain temperature to the vapor pressure at that temperature, the liquid produces a bubble. The phenomenon of producing bubbles is called cavitation. When the cavitation bubbles, flow to the high pressure, the volume of reduced, so as to burst. This due to the pressure of rising bubbles disappear in the liquid in the phenomenon called cavitation bubble collapse.
Q:What is the difference between centrifugal pump and positive displacement pump?
Positive displacement pump is the volume pump, this type of pump is to rely on changes in volume to compress fluid work, including: diaphragm pumps, gear pumps, screw pumps, etc.;

1. Manufacturer Overview

Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range