• Multistage Centrifugal Water Pump for Boiler Feed System 1
  • Multistage Centrifugal Water Pump for Boiler Feed System 2
  • Multistage Centrifugal Water Pump for Boiler Feed System 3
Multistage Centrifugal Water Pump for Boiler Feed

Multistage Centrifugal Water Pump for Boiler Feed

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
10000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

                      Multistage Centrifugal Water Pump for Boiler Feed

1.Structure of Multistage Centrifugal Water Pump for Boiler Feed

The high presuure boiler feed multistage water pump is a horizontal multistage centrifugal pump and suitable for transporting pure water,both ends of it are supported,the casing portion is a senctional form,it is connected and actuated by motor via a resilient clutch.From the driven direction,the pump rotated direction is clockwise.

2.Main Features of Multistage Centrifugal Water Pump for Boiler Feed

• High Effiency

•Low noise

Long life, OEM and ODM are welcomed.

3.Horizontal Multistage Centrifugal Water Pump Images

High Pressure Boiler Feed Multistage Water Pump

4.Horizontal Multistage Centrifugal Water Pump Specification

Material

 

Cast iron and as customer's request

Temperature

 

Less than 150°C

Flow rate

              3.75-300m3/h

Head

75-1000m

Medium temperature

0 ~170°C

Operation pressure

≤40 bars

5.FAQ

①What is the applications?

Power Station,Industry Water Supply

How to guarantee the quality of the products

We have established the international advanced quality management systemevery link from raw material to final product we have strict quality testWe resolutely put an end to unqualified products flowing into the market. At the same time, we will provide necessary follow-up service assurance. Normally, We have 1 year warranty.

 


Q:Double floor sewage pump circuit diagram of a small problem
Question 3 when the water level is low, when the 1KA is connected, the pump will run depending on where your SS selector switch is located. Its left and right position, running pump and standby pump definition is different, left position is 1#, running 2# standby, right position is 2# running, 1# standby. Only inIn case the high level switch 2KA is connected, the standby pump may work at the same time.
Q:What's the difference between a centrifugal pump and a centrifugal pump? What are they used for?
As the name suggests, centrifuges are machines that achieve centrifugal effects by centrifugal action. And you say the centrifugal pump is only specific, and the same as the pump
Q:How many kilograms of water pump are there in the automatic washing machine on the market?
Longer service life. Automatic switch water pump, car wash automatically open and stop, easy to operate, not easy to bad, repair rate is low!!!
Q:What is a solution pump?
(4) smooth running, low noise, no lubrication, no lubrication and low noise due to the absence of rolling bearings and motor fans(5) a wide range of use, the high temperature, high pressure, low temperature, high melting point and other conditions are able to meet the requirements2.2 shielding pump shortcomings(1) because the shielding pump adopts sliding bearings and is lubricated by the medium to be transported, the medium with poor lubricity should not be transported by shielding pump. Generally, the viscosity of the pump medium is 0.20mPa.s.(2) the efficiency of shielding pump is usually lower than that of single end mechanical seal centrifugal pump, which is approximately equal to that of double end mechanical seal centrifugal pump(3) long time in small flow operation, shielding pump efficiency is low, will lead to heat, make the liquid evaporation, and cause the pump to dry, and thus damage the sliding bearingsCanned pumps can be divided into the following types: 1) basic type 2) reverse circulation type 3) high temperature type 4) high melting point type 5) high pressure type6) self priming 7) multi stage 8) mud type
Q:What is a gear pump for?
Oil pump casing wearIt is mainly the wear of the floating sleeve hole (the normal clearance between the gear shaft and shaft sleeve is 0.09~0.175mm, and the maximum shall not exceed 0.20mm). The gear work is affected by the pressure oil, the gear tip is close to the oil pump casing, and the low pressure chamber part of the pump body is worn. Another kind of wear is the circumferential wear of the work surface in the shell. This kind of wear is mainly caused by the addition of oil which is not clear, so the oil without impurities is necessary.
Q:Why does the centrifugal pump start with a closed valve and the axial pump starts with an opening valve?
The power of axial flow pump decreases with the increase of flow rate, and it is a steep curve, so the centrifugal pump starts with an open valve.
Q:Why is the submersible pump tripped on an electrical switch?There is no electrical leakage protection, directly connected to the circuit breaker, and when the switch on, the circuit breaker jumpedI checked the line is good, the pump did not break down, is not the water pump?
There should be the following reasons: 1) the setting value of the trip switch is too small, and the operating current of the submersible pump exceeds its setting value, and the switch is tripped
Q:What does centrifugal pump mean horizontally?
In other words, pump casing and pump body along the horizontal center of the pump leaves into the upper and lower halves, so that when the pump leaves the pump cover open, you can pump and bearings as a whole pumping out. No need to remove the pipe. I don't know. Do you understand?.
Q:Must the water pump in the tank be all soaked in water?
Need a submersible pump in the water, but it is not entirely like this, I have to work for a long time no problem in water, but there is a problem you should pay attention to the water pump, at least in half, or stop when the smoke is not on water.
Q:Common failure treatment of piston pump
x09x09 (3) no connecting key on pump shaft or motor shaft1) break2) missing x091) replace key2) patch keyx09x09 (4) pump internal slide vice stuck1) the clearance is too small2) parts accuracy is poor, assembly quality is poor, gear and shaft coaxial deviation is too large; plunger head clamping; blade perpendicularity difference; rotor pendulum difference is too big, rotor slot has wound or blade has scar, force after fracture and stuck

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords