PVC Coated Wire
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
Quality Product, Order Online Tracking, Timely Delivery
OKorder Financial Service
Credit Rating, Credit Services, Credit Purchasing
You Might Also Like
Quick Details
Place of Origin: | Certification: | Model Number: | |||
Surface Treatment: | Type: | Function: | |||
Wire Gauge: | Place of origin:: | Raw material:: | |||
Surface treatment:: | Coated material:: | Pvc color:: | |||
Inner wire:: | Wire diamter:: | Wire gauge :: | |||
Payment Terms:: |
Packaging & Delivery
Packaging Detail: | 0.5KGS-1000KGs per coil. wrap with plastic film, Hessian cloth or moister-proof paper. |
Delivery Detail: | 20 days after received the deposit or customized. |
Specifications
1.Purity raw material with ISO 9001
2.Surface:pvc coated
3.Inner wire diameter:0.8-4.0mm
4.OEM service with fast delivery
- Q: Basically I have a 3000watt amp, and I need to buy the right wires. Would I still manage to get the full power out of the amplifier with 1000w speaker wiring kit or do I need to buy a 3000w speaker wiring kit?If so, where is the difference with the higher wattage wiring kits.Thanks
- Wire okorder with free shipping Goodluck
- Q: I was looking at the wiring of my current thermostat and I want to know why it's wired the way it is...The yellow wire was wrapped around the white terminal and the yellow terminal. And the white wire was wrapped the around the Orange terminal. The red and green wires were each wrapped around their respective terminals. And the blue wire wasn't connected to anything. Why would the electrician have wrapped the yellow wire around 2 terminals? Is that normal? Also, I tried installing a new thermostat but the heating is not working. The fan works but it just blows room temperature air. The new thermostat only had 4 terminals for R, Y, W, G. I connected the wires I had to their respective terminals. However, I think it may not be working because I have a probably have a heat pump. Any Ideas why else it might not be working? Thanks a lot!
- You should take sketches of the thermostats and wires to your favorite plumbing heating store, and talk to a service person, if you feel competent enough to do the proper connections yourself. Also, include details of the thermostat wiring connections to your heating unit. Otherwise, get such a person to come over to your house to do the work.
- Q: Can you wire an extention cord to low voltage wireing? to like malabu lights
- No. Malibu lights are made to be permanently installed, as is the wire made for them . Extension cords are made for temporary use. If you are asking if you can power malibu lights directly from an extension cord connected to high voltage power, no, that would blow them up.
- Q: i have some blue speaker wire in my wiring kit for my subs but where do i start it out from my head deck when i start to wire it all together.
- The remote wire is for the remote turn on for the amp. It connects to the blue/white wire from the head unit (aftermarket) to the REM terminal on the amp. If your using a stock head unit, you can run the fused (1 amp, added to the blue wire from the fuse panel) blue wire tapped from a fuse that only has power when the car is on to a switch. From the other side of the switch run the same blue wire to the REM terminal on the amp. This allows for full control and you never have to worry about forgetting to turn off the amp.
- Q: Hello, I have a 4 year old Trane XR12 unit. Recently the compressor fan is noisy, and now stops when when under power after 5-10 min. The main fuses and breakers are fine, the fan spins freely when turned, the contactor pulls in fine, the dual capacitor checks out. But, the wiring of the capacitor does not match wire diagrams. Could this have caused the fan motor to prematurely fail?..............................Terminal: C red wire, FAN brown wire, HERM has both orange and purple. Schematic shows the purple wire should be with red wire on common C. The purple also leads to fan.
- Hi, I looked at the schematic on-line. If you still have the original fan motor in the unit then you are correct. The center terminal on the capacitor should have the red wire from the T1 terminal of the contactor, the red wire from the compressor, and the purple wire from the fan. The FAN terminal should have the brown wire from the fan. The HERM terminal should have the orange wire from the compressor. The black wire from the fan and the black/blue wire from the compressor should lead back to the T2 terminal of the contactor. Again, that is if the motor is the original motor. If it was replaced at some point in time, the wiring colors can change from manufacturer to manufacturer, in which case it's possible that the new motor is wired correctly. There should be a diagram on the motor to show you the correct wiring configuration.
- Q: Both wires are black. One has what looks like white paint on it.
- correct.....both can be hot, as they may have been cris crossed from point to point. the best is to get a volt meter and test to your water pipe if its grounded and not eroded away over the years. problem with using an inductance tester is it may give an erroneous reading if they have been cris crossed. note.....once you find the hot of the two, the other bing the neitral will have a current on it that can be fatal, remember there is no ground to protect you, and if your in water or touching something metallic, you may be the ground path needed to complete the circuit. be careful!
- Q: What are the types of Barbed wires?
- Barbed wire is barbed wire as far as I am concerned. Otherwise google barbed wire manufacturers and see what they can supply.
- Q: My starter I replaced has 3 wires, two red and one black. Where does each wire go? Pictures would be very helpful if possible
- based upon the gauge you have... i do no longer think of you're placing it to a mustang yet i detect genuine low-priced air stress gauges are very deceptive.. your 5.0 may well be 50 psi (if it relatively is prolonged each and every of how out) and is a great way overinflated. the properly suited tire stress is the two interior the glove container on a plaque interior the door or is a sitcker on the rear door section.. yet stress could desire to be form of 32 psi (220 kps for our metric friends) on your motor vehicle in case you haven't any longer pushed it for greater effective than 8 hours...
- Q: Need ro know where to put the wires correctly
- the terminals are colour coded, green for the green or ground wire, brass coloured for the live wires ( the red and black ones) and silver for the white wire.. make sure the power is off!!! it only takes 40 volts a 60 hz AC to KILL! look close for GRN for ground and green, LOAD or LINE for the black or red wires and further for NEUTRAL, ( N) or Neut. for the white wire...YOU CAN CHECK FOR POWER WITH PIGTAIL white to white and black to either black or white one at a time...post again so we know if your alive...
- Q: I'm trying to hook up my second phone line. I have a red, green and yellow wire in the cable, but no black wire. Is there a reason for this? And what can I do to get the second line up and running? thx
- the wire you have is designed for 1 line only. Back in the day the yellow wire was used to carry ground because ground was necessary for old circuits. Ground is no longer needed so in order to get two lines you need at least a two pair wire (meaning four wires) you might have to run a new wire unfortunately or just keep that one and run another to separate jack.
Send your message to us
PVC Coated Wire
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
Quality Product, Order Online Tracking, Timely Delivery
OKorder Financial Service
Credit Rating, Credit Services, Credit Purchasing
Similar products
Hot products
Hot Searches
Related keywords