Engineering Flooring For Flooring Heating

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1800 m²
Supply Capability:
100000 m²/month
Inquire Now Customer Service

Contact us by

(1) WeChat
(2) Whatsapp: +8617190086776

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Description:

Engineering  Flooring For Flooring Heating


Specification: 

490/600X70X10mm,4mm top layer;

600/900X90X10mm,4mm top layer;

Color: Natural

Joint: Tongue & Groove

Grade: AB
Finish: UV lacquer/UV oiled (PPG brand);
Bevel: Square Edge;
Moisture Content: 8-12%;
Glue: PF;
Plywood: Meranti,beech, poplar mixed;
Available Surface: Flat, distressed or handscraped;

 

Formaldehyde emission: CARB standard;

Available Certificates: CE,ISO9001, CARB, FSC;

Other wood species: American Walnut,White Oak,Ipe, Tigerwood, Hickory, Meranti, Cherry, Sapele, Maple, Birch, Elm,etc.


Photo:


Engineering  Flooring For Flooring Heating

FAQ:

① why from okorder?

Okorder is a qualified supplier of all kinds of building matierials in China. All products have been showed in Okorder website are under well controlled by okorder QC team.

All products had been produced under a clear quality standard and the quality is consistence among the shipments.

Okorder has already setted up more than 20 warehouses in different markets to show the products. You are convenient to know the products from your local place and it will help you to make decision easyly.  

②How to guarantee the quality of the products?

We have established a perfect quality management system,as for raw material and semi parts all are under strict quality test and we have a IQC system to control the purchases.

QC on site is very strict and all steps of process are measured per drawings. Before delivery, we set a OQC system to make sure each piece meet the standard of order.from design to delivery, 

③How long can we receive the product after purchase?

Lead time depending on order quanity, The normal order can be deliveried with 3 weeks.


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Which brand is good to warm?
First of all you have to understand, to warm is a system, not just a component or a product, to warm the brand is almost the quality of the company to warm and the installation process to decide. The heating company is indeed a difficult problem, need to consider a lot of factors, first, the company good reputation; second, the company size to large; third , With the quality of the material reliable, the best choice of a level of energy efficient boiler, and now high gas costs, can save a lot; Fourth, the construction should be standardized, have their own construction company or construction team; fifth, have special Of the after-sales department; this is my own home in the election heating company summed up, hoping to help you.
Q:How to connect the natural gas boiler
There are five tubes below the natural gas boiler, look at the instructions you will understand. They are: heating water, heating back to the water, tap water, sanitary hot water, gas pipe. 1, connected to warm, then, is the "heating water", "heating back to the water," the two water pipes connected to the floor to the water heater, the warm water separator has two rows of metal valves, two joints, and the boiler Of the heating water, heating back to the water two interface docking. Usually above a row of water supply, the following row of water back. But it does not matter. 2, the gas pipe and the gas pipeline to be connected at home, if the home inside the gas pipeline only one connector, to take a three links before they can connect the boiler and gas stove. 3, tap water, and the home should be connected to the water pipe, used to add pressure to the heating system, and the supply of bath, wash your face, vegetables and other water. 4, sanitary hot water and water, and the need for hot water at home tap, such as shower, washbasin, wash the pool and so on. Note 1, 1, the connection of the boiler related to the installation of gas pipeline transformation, the need for a corresponding qualification, and to the local gas company to declare. 2, in the clear understanding of each interface before the boiler, do not rush to connect, boot, so as to avoid damage to the boiler parts. 3, the boiler / floor heating work pressure generally 1-1.5bar between the working temperature of 45-55 ℃ between. Too high temperature and pressure, is not conducive to the warm life. Maidi Si boiler, dedicated to your service.
Q:Home gas boiler why the circulating pump is always non-stop turn?
Gas boiler water pump will automatically start and stop according to the water temperature, under normal circumstances during the water pump is kept non-stop. Because the pump operation can make the system temperature uniformity, the temperature inside the furnace can reflect the system temperature. But not all brands of fireplaces are so. So the pump motor is not working properly.
Q:What kind of material does the radiator have? Which is the best, thank you
The most important are steel radiator, aluminum radiator, copper radiator, copper and aluminum composite radiator four categories. Here we come to detail the four types of radiators, compare the pros and cons between them. Steel radiator steel radiator for the heating system water quality requirements are high, if in an unsafe heating system prone to corrosion. Aluminum radiator aluminum film heating film requirements of the system water quality PH value greater than 7, but it is not subject to residential heating system restrictions, even in the open boiler system Fan Dun Dun feel rustling rudder grinding pulp can not be oxygen corrosion. Aluminum heat dissipation is better, the characteristics of energy-saving is very obvious, in the same room, if the same specifications with the radiator, the number of aluminum cast less than steel Copper heating film copper material heating film on the system of water quality and residential heating system temperature is not limited, the biggest drawback is the price is relatively expensive, some HVAC supermarket has not run the copper radiator. Copper and aluminum composite radiator type copper and aluminum heating film on the system of water quality PH and residential heating system is also no limit, because it is a copper structure inside, good oxidation resistance, and its external due to a layer of aluminum , So the cooling effect is better. These four radiator performance is significantly different, the best performance of the radiator is copper-aluminum composite radiator, but for home users, comfortable 100 recommended to recommend you use aluminum radiator, both to ensure the use of radiator effect , The price is not too high.
Q:110 level two-story to warm the boiler heating and living hot water with much model
24KW boiler can be used for the whole family .....
Q:What is the air source heat pump to warm air conditioning two for the system
1 air energy (source) heat pump is driven by the motor, the use of steam compression refrigeration cycle principle, the ambient air for the cold (hot) source of cold (hot) wind or cold (hot) water equipment, the main components include Hot side of the equipment, heat source side of the heat transfer equipment and compressors. 2 air energy (heat source) heat pump using the heat in the air as a low-temperature heat source, through the traditional air conditioner in the condenser or evaporator for heat exchange, and then through the circulatory system, extraction or release of heat, the use of unit circulation system to transfer energy to the building Objects, to meet the user's life hot water, floor heating or air conditioning and other needs. 3 current multi-function heat pump is generally called triple supply, refrigeration, heating, hot water three functions of the unit. Cooling mode can get free living hot water, energy efficiency is very high, heating mode can do floor heating, radiator, hot water and so on. If it is two for the system, then one of them may not be provided.
Q:Home 200 square meters electric heating boiler
Power too much friends, as replaced by solar energy
Q:Water pressure test should meet the requirements
(1) The hydrostatic test shall be carried out after the system has been flushed. (2) water pressure test should be per component, the collector as a unit, by group or by loop. (3) water pressure test should be carried out twice, respectively, before the pouring of concrete before the reign of rough rougers and the filling layer after the expiration of the maintenance of the filling tube; the best heating pipe laying before doing a test. (4) the test pressure should be 1.5 times the working pressure, and should not be less than 0.6Mpa. (5) test method: the test pressure, the regulator 1h, observe the pressure drop, if the pressure drop is not greater than 0.05Mpa, that qualified. (6) water pressure test should be used to slow down the manual pump, boost the process to observe and check the presence or absence of leakage. (7) in the case of freezing may test pressure, the pressure test pressure should be completed after the tube of water to dry, but only the air pump is blowing is not clean, it is recommended to use warm cleaning special tools, Each road tube, for drainage, so that the real guarantee of each tube, there will be no drop of water to ensure that no pipe freezing, practice has proved that there are many use of air pressure test.
Q:Walled gas heating furnace is good or not better to protect the water
No water can better protect the equipment and normal operation, the reasons for the following: 1, the current boiler, whether it is a tube machine or board replacement, hot water in summer when the boiler needs a certain amount of water pressure, This pressure refers to the system pressure, that is, the heating system of water pressure, the summer of hot water is to rely on heating water within the system to heat, but the board switch using three-way valve and pump in the boiler to do Small circulation, the casing pump does not turn the water in the main exchanger to heat the heat, so there is no water in the heating system in the summer mode hot water can not be provided. 2, the current use of a lot of heating system is the radiator films, especially in the majority of steel radiators, summer is not blessed to support the younger brother of the tripod to visit the Austrian poetry Dingjian water can reduce the corrosion of the radiator to extend the service life. 3, do not let the water can reduce the scale of the amount of production, frequent system water or water will increase the chance of scaling the system. 4, no water In the case of boiler power, the boiler is in standby mode, in accordance with the program settings, part of the protection function into effect, can reduce the three-way valve, pump and other mechanical parts of the lock.
Q:To warm the construction, structure and filler selection and how to coil?
To warm is actually a more complex system engineering, only concerned about the quality of the product is not enough. Do the floor insulation system should be laid before the construction of civil walls have been completed, and done the basic leveling, the venue no other types of construction in the construction. The temperature of the construction room should be in accordance with the required temperature of the pipe used, because the ambient temperature and the bending radius of the pipe are closely related. Cleaning the ground and the wall, the use of level ruler on the ground flatness, within 1 meter height difference is less than or equal to 5 mm. Wall or ground protruding part of the shovel with the shovel, filled with concrete pits on the ground. Bathroom and the bottom of the villa should do a good waterproof layer or laying moisture film.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range
客服
live chat