Hot Dip Galvanised Steel Wire
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Commercial Galvanised Steel Wire
(1) Quality : Meet GB/T 343 standard and other requirements of relevant standards .
(2) Zinc Coating: Meet GB/T 15393 standard and other requirements of relevant standards .
(3) Raw Material : Wire rod ——1006 , 1008 , 1018 , Q195 , etc, and zinc with 99.995% purity.
(4) Tensile Strength Range
Size (mm) | Tensile Strength (mpa) |
0.15-1.60 | 290-550 |
0.65-1.60 | 400-550 |
1.61-6.00 | 400-1200 |
(5) Application : Used in wire mesh , artware , metal hose , binding for agriculture and construction , etc.
(6) Packing
Size (mm) | Coil Size | Spool Packing | Big Coil Packing | |
ID (mm) | OD (mm) | |||
0.15-0.26 | 6 inch | 1-14kg/spool |
|
|
0.27-0.60 | 8 inch | 1-100kg/spool |
|
|
0.61-1.60 | 12/14/16 inch | 1-100kg/spool | 250-400 | 400-770 |
1.61-6.00 |
| 14-500kg/spool | 450 | 800 |
508 | 840 |
(7) Zinc Coating
Meet GB/T 15393 standard.
Size (mm) | Weight of Zinc-Coating ( g/m2 ) | |||||||
A | AB | B | C | D | E | F | ||
A1 | B2 |
|
|
|
|
|
| |
≤0.25 |
|
| 30 | 20 | 18 |
|
|
|
>0.25-0.40 |
|
|
| 30 | 25 | 20 |
|
|
>0.40-0.50 |
|
|
|
| 30 | 20 |
|
|
>0.50-0.60 |
|
|
|
| 35 | 20 |
|
|
>0.60-0.80 | 120 | 110 |
|
| 40 | 20 |
|
|
>0.80-1.00 | 150 | 130 |
|
| 45 | 25 |
|
|
>1.00-1.20 | 180 | 150 |
|
| 50 | 25 |
|
|
>1.20-1.40 | 200 | 160 |
|
| 50 | 25 |
|
|
>1.40-1.60 | 220 | 180 |
|
| 50 | 35 | 30 |
|
>1.60-1.80 | 220 | 180 |
|
| 70 | 40 | 30 |
|
>1.80-2.20 | 230 | 200 |
|
| 80 | 50 | 40 |
|
>2.20-2.50 | 240 | 210 |
|
| 80 | 55 | 40 |
|
>2.50-3.00 | 250 | 230 |
|
| 90 | 70 | 45 |
|
>3.00-4.00 | 270 | 250 |
|
| 100 | 85 | 60 | 30 |
>4.00-5.20 | 290 | 270 |
|
| 110 | 95 | 70 | 40 |
>5.20-6.00 | 290 | 270 | 245 |
| 110 | 100 | 80 | 50 |
- Q:My telephone doesn't work. No Dial tone. When I plug the phone into the box outside the phone works so that tells me it is the wiring going into or in the house. The phone repairman put in a new phone box outside because the old one wasn't accessible anymore (we accidentally built a porch over it) when he did that he spliced the wire going from the old box to the new box. The wires that he spliced hang down under the porch. There are 4 wires coming out of each wire, but only two are spliced together. Should the other two be spliced also? I'm thinking maybe they were but my dog has messed with them. The phone service went down all of the sudden and I don't really know anything else to check. Any ideas?
- each phone line uses a pair of wires (2 wires) these wires would normally be green/red or blue/white and solid blue for line 1 and if needed yellow/black or orange/white and solid orange for line 2... you did the first step in troubleshooting to know that the trouble resides inside your home... so when you call into your line does the phone ring busy (or go straight to voice mail) or does it just keep ringing.... if it rings busy (or straight to VM) then there is a short on the line... this is possibly a defective phone, a phone that is off the hook, or a bad jack or wire... if the phone just keeps ringing, then there is a broken wire somewhere...... since the old NID is no longer accessible, you may need to run a section of wire from the new NID to one of the existing jacks in your home to back feed the jacks... if you do this i recommend disconnecting the wire that is going from the new NID to the old NID, as if you reverse the polarity you may end up shorting out your line with the new wire...
- Q:i have a 98 ford taurus... can anyone give me a diagram of the wires that come off the radio, like wut colors r which speakers. i need to knw so i can wire it my cd player cuz i cant get a wire harness around here..
- just take it to a profesional so you dont f uck it up
- Q:wiring diagrams
- Usually just find a spare socket to plug it into. Difficult bit is getting the plumbing right - read all the information supplied with the pump or look on the web before you buy it.
- Q:Where can I purchase small wire of a large quantity that is similar to wire on cellular phone chargers?The wire im looking for needs to handle no mare than 12 volts.
- Belden is a good source, there are lots of other. But I suspect you want a multi-wire cable, not a wire. You need to specify the number of conductors, and the size of each. The 12 volts is not relevant. The insulation voltage is. Also, note that for long runs, you have to increase the wire size. .
- Q:For my braces, the top wire where my two front teeth are, I can push the wire and it sort of bend. I don't know if this is normal or not. Can someone tell me?
- Yup its normal. Some of the beginning arch wires that are used are made up of very flexible metals like Nickel Titanium or Sentalloy. They are designed that way to help your teeth unravel for lack of a better term. These wires will allow your teeth to do the most movement. So no worries. But I would definitely try not to bend your wires, as you move along in your treatment some wires are not meant to be bent unless your orthodontist does it because your teeth can move in the wrong direction. Rest assured it is normal.
- Q:One wire has part of the plastic coating on the end, the other wire does not.
- the lead is the wires showing. lead wire can also mean attaching a wire and feed it through a wall attach other end to the wire and pull it through. Now if you need both ends to have wire showing take a utility knife firmly place wire on block of wood and lightly cut through the caseing. thats the thick wire that en cases the other wires and peal back and then cut it off. then carefully hold blade of utility knife and wire aganst your thumb on a 45 degrees away from you and pull that will strip the plastic off the wires hope that answers your question dave
- Q:Ceiling lights wire guage
- Most localities use the NEC (National Electric Code) as their source for wiring requirements. Smallest gauge allowed for ceiling lights is #14.
- Q:wiring for generator
- Shut the main breaker so you are off the grid and plug the generator into your dryer plug to reverse power your panel. Shut off the big things at the fuse box, AC, hot water heater, etc.
- Q:I have a proj in tle class about solid wire joints and splices and i cant find a picture of 18 of the splices / joints we did at school we needed to like insulate the wires and twist em with each other help!
- Electrical Splices And Joints Pictures
- Q:Need to know what colors are for what and the function of each wire.
- 2002 Chevrolet Tahoe Car Stereo Radio Wiring Diagram Radio Constant 12V+ Wire: Orange Radio Ignition Switched 12V+ Wire: Class 2 Serial Data Radio Ground Wire: Black/White Radio Illumination Dimmer Wire: N/A Radio Antenna Trigger Wire: Dark Green Radio Amplifier Trigger Wire: Pink (If equipped, the amplifier is under the center console.) Front Speakers Size: N/A Front Speakers Location: N/A Left Front Speaker Wire (+): Tan Left Front Speaker Wire (-): Gray Right Front Speaker Wire (+): Light Green Right Front Speaker Wire (-): Green Rear Speakers Size: N/A Rear Speakers Location: N/A Left Rear Speaker Wire (+): Brown Left Rear Speaker Wire (-): Yellow Right Rear Speaker Wire (+): Blue Right Rear Speaker Wire (-): Light Blue
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Hot Dip Galvanised Steel Wire
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Related keywords