Factory price china yuchai diesel generator sets 60kw

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
300 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

pecifications

open type dioesel generator with yuchai enginee 
1) Factory direct sale 
(2) CE, ISO9001 quality 

Power range

18-650KW

Engine

All series powered by Yuchai engine

Alternator

All series owning alternator options of Stamford/Marathon/ENGGA

Controller system

Hanging control box, automatic control module Smartgen HGM6310

Base frame

International channel steel welded base, inbuilt composite damping system; sandblast, acid-washing, antiseptic treatment

Radiator

Standard genset-joining radiator of 40 °C ambient temperature

Diesel generator Powered by Yuchai Engine,which yuchai is a large state-owned enterprise and a Nasdaq listed company in USA (NYSE:CYD). Its main business covers diesel engine, contruction machinery, vehicle parts. The engines produced by Yuchai include series YC6G, YC4G, YC4E to which American technology applied, series YC6A, YC6B, YC6J, YC4B, YC4D, YC4F, YC4W to which German technology applied, and YC6M series in which world top technology integrated, totally 12 series.

 

YUCHAI SeriesPower(KW)Power(KVA)Jichai Engine ModelCylinder NO.Fuel consumption
g/kw.h
DimensionL*W*HWeight  
 KG
FKS-Y181822.5YC2108D2≤2251700*700*1000650
FKS-Y242430YC2115D2≤2201700*700*1000650
FKS-Y303037.5YC2115ZD4≤2051700*750*1000900
FKS-Y404050YC4D60-D214≤2051800*750*1200920
FKS-Y505062.5YC4D85Z-D204≤2001800*750*1200950
THY-646480YC6B100-D206≤2052250*800*13001200
FKS-Y757593.75YC6B135Z-D206≤2022250*800*13001250
FKS-Y9090112.5YC6B135Z-D206≤2022250*800*13001300
FKS-Y100100125YC6B155L-D216≤2002300*800*13001500
FKS-Y120120150YC6B180L-D206≤1922300*830*13001600
FKS-Y140140175YC6A210L-D206≤1922300*830*13001700
FKS-Y150150187.5YC6A230L-D206≤1922400*970*15002100
FKS-Y160160200YC6G245L-D206≤1952500*970*15002300
FKS-Y180180225YC6L285L-D306≤1972600*970*15502500
FKS-Y200200250YC6M350L-D206≤1973100*1050*17502750
FKS-Y220220275YC6M350L-D206≤1973100*1100*17502800
FKS-Y280280350YC6MK410L-D206≤1953200*1150*17503000
FKS-Y300300375YC6MK470L-D206≤1953200*1200*17503100
FKS-Y320320400YC6K500L-D306≤1953250*1200*17503200
FKS-Y350350437.5YC6K550L-D306≤1953250*1250*17503250
FKS-Y350350437.5YC6T550L-D216≤1953300*1250*18503500
FKS-Y400400500YC6T600L-D226≤1953400*1500*19703900
FKS-Y440440550YC6T660L-D206≤1953500*1500*19704000
FKS-Y500500625YC6T755L-D206≤1954000*1500*20005000
FKS-Y650650812.5YC6C1020L-D206≤1954500*1800*25007500


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What gas powered generators are the suitable for running 24 hours a day? but not too pricey.?
Any generator that is suitable for continuous operation will seem very pricey. If you pretend that each dollar weighs a pound, such a generator will cost a lot more than a ton of money. It will also run on either diesel or natural gas, not gasoline. Contact Generac, Caterpillar, and other generator manufacturers for information.
Q:What would be the purpose of building a Hybrid-Diesel car for?
Diesel -electric has long been used in trains, buses, ships, mine equipment. Diesel has 30% more energy per gallon over gasoline. Diesel is a by-product that is refined from trying to make gas from crude oil. Diesel can also be made from soy beans, coal oil, vegtable oils, used cooking oils. The new Blue tec diesel engines exhaust is even cleaner then the air that went into the air filter--(cleans the air as you drive). Diesel doesn't evaporate ,. The old vw rabbits use to get 48 mpg highway---that was 24 years ago, diesel engines have gotten cleaner and more powerful for their size. Generators normally never go above 3600 rpms. So the idea of a engine that has so many ways to make the fuel, fuel that has more energy per gallon, cleans the air as it drives, the engine has plenty of torque for it's size and weight---just makes scents to me that it would make a good hybrid
Q:I am asking this simple question 4th time but nobody knows its answer.why?
Divide the number of hours the motor ran by the number of gallons used. ex. 100 hours run time divided by 5 gallons used 20 hours per gallon. Hint - sometimes if you oversimplify your question, people don't understand what information you are asking for.
Q:synchronizing generators?
The only thing I can think of is watch the second Thomas Edison Bio film and pay careful attention to when he is working on lighting up the city using his electric light bulb. He had to synchronize two generators at that point. I'm sure you can find the answer there.
Q:Is there any way I can run electricity outside home for long periods of time (cheaply)?
There are only two real choices, batteries, or a gasoline/diesel driven generator. To store that amount of power via batteries, you would need about 11 large auto batteries. A 100 amp-hour lead acid battery can store about 1 kW-hour, and you need 0.6kWx18hr 11 kW-hour. You need marine deep discharge batteries and they cost about $300 each, plus charger costs, so a generator would be cheaper. You can get a 800 watt generator for $300. OR if outside home is literal, you can run a long extension cord.
Q:Can a decent electric car or truck conversion be made using a 9.8kw gas/generator with batteries?
Good luck driving a car wiht a 10 horsepower motor.
Q:how much diesel does an 5MW generator use?
the rule of thumb is that an efficient diesel, working continuously burns 1 gal/hr for every 15hp developed. A 5MW generator therefore requires about 6,705 hp. 6705/15 447 gal/hr in 30 days30 * 24 *447 321,840 gallons. Given that very large engines can be extraordinarily efficient, which will make up for some of the mechanical and electrical losses, a good guess would be 300,000 gallons
Q:Electric Power Generation by Diesel generators?
With that large a system, you should get a quote from professionals. You need better numbers on power usage, both average and peak. And the pros can help with that. See if you can get a sample of 10 electric power bills and use that as an average to calculate the average power for all 250. Peak is difficult. They each have 4.5 ton worth AC? must be a hot climate. You can use 1.2 kW per ton, so that is 5.4 kW per house or 1.4 MW total just for the ACs Is there electric stoves, hot water, etc? that could double the above number. So we are up to perhaps 3 MW already. At that level, you probably need a higher voltage system, perhaps a 6 kV distribution system. That costs money, plus all the transformers, one per 2-4 house, plus all the underground digging. Assuming you want this underground, not on poles. Again, contact a company that does this, such as Siemens, Bosch, GE, they would be happy to give you a good quote. edit: when you look at the ratio of peak power to average power, you will see a large number, as high as 10. that means you could require a (eg) 3 MW generator although the average power is only 0.3 MW. That means the efficiency is low and the costa are high. That is why large power distribution systems are much better, as the peaks are not nearly as high, and also power companies have special units that are usually offline and come online to handle the peaks.
Q:What refrigerator uses the least amount of electricity. (domestic or foreign)?
the one with the lowest wattage rating, either domestic or foreign. just make sure it is made to work with the output of your generator ie; voltage and cycles
Q:Would the fukushima disaster had happened if the nuclear reactors had not gone into emergency shut down?
if hte control rods had not be inserted it would of catastrophic. the reactors would be working at 100% and no one can shut it down becasue there is no power. left for too long and unable to stop the reaction, it could lead to an actual meltdown like at the Chernobyl. there's a good reason why during any emergency the control rods are inserted. its standard protocol since the very first nuclear reactor experiments back in the late 1930s under some gym in the eastern USA. you want to shut down the most dangerous thing first, the one that has the most potential for catastrophe before doing anything else.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range