• Double Entry Centrifugal Pump Made In China System 1
  • Double Entry Centrifugal Pump Made In China System 2
  • Double Entry Centrifugal Pump Made In China System 3
  • Double Entry Centrifugal Pump Made In China System 4
Double Entry Centrifugal Pump Made In China

Double Entry Centrifugal Pump Made In China

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
1000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Item specifice

Item:
Double Entry Centrifugal Pump Made In China
Material:
Cast Iron ;Stainless Steel
Power:
Electric
Exporting countries:
Ameircan,Japan,Australian etc
Application:
Customer Required

Double Entry Centrifugal Pump Made In China 

Application

Single Stage Double Suction Split Case Pump is used for conveying water or the physical and chemical properties similar to water and other liquids suitable for factories, mines, urban water supply, power stations, agricultural irrigation and water conservancy.


Characteristic

Compact structure,beautiful outline,stable operation,low noise;

Both inlet and outlet of this pump are placed under the axial line,so it is unnecessary to remove the inlet and outlet pipeline and motor;

The shaft seal of water pump has fine mechanical seal and soft stuffing seal,which can be selected according to different condition by user;

The impeller is static-balance calibrated,fixed on the shaft with round nut,and its axial position can be adjustedvia the round nut;

The pump is direct drived by motor via resilient coupling,it can be drived by internal combustion engine if it is necessary.



Technical Data


Capacity50-20000m3/h
Head10-230m
Speed2900/1450/980/740/580/3500/1750/1180/890/710rpm



Material

Casing: Cast iron/ ductile cast iron/cast steel/stainless steel/duplex stainless steel

Impeller: Cast iron/ ductile cast iron/brone/stainless steel/duplex stainless steel

Shaft:C-steel/stainless steel


The rotation direction

Viewed from motor, the direction of the pump is anti-clockwise,that is the suction in the left, the discharge in the right.

The rotating direction of the type pump is clockwise, that is the suction in the right, the discharge in the left. 

Also can move the driver to another edge according to the user’s requires. Then, the rotating direction, the suction and discharge direction is in the opposite as the described above.

 Photo

Double Entry Centrifugal Pump Made In China



Q:Mercedes 2000 ml 320. I changed radiator and water pump now car only runs half as worm than it used to. So now heat blows cold to little warm depending on how cold out side
FIT NEW THERMOSTAT
Q:2005 pontiac grand prix 3.8 v6There is a scratching type of noise when i start the car. Looked under the hood and it seemed to be coming from the serpentine belt.Took the belt off and and checked the pulleys for any play and turned out the water pump pulley wobbles back and forth too much. Replaced the belt with a new one and want to replace the pulley. It does not seem to have a loose screw so i'm wondering if i can take the pulley itself off and replace it, or would i have to replace the pump too? Still makes the noise with new belt and you can see the pulley wobble a bit when the car is running.
you have to replace the pump ! it,s not the pulley that,s wobbling, it,s the bearing in the water pump that,s bad and you can,t replace the bearing !
Q:Relationship between power and flow of sewage pumpFor example, how much power waste water pumps do 1m3/h and 100m3/h need?Best detailed listShow the relationship between power and flow
There is a formula for motor power = flow (m3/h) * lift head (meter), *9.81/3600/ efficiency (general sewage pump efficiency is about 55%), *1.2 (motor safety factor)For example, 10 tons of flow, lift 10 meters, how much power?N=10*10*9.81/3600/0.55*1.2=0.595. so the motor power we chose should be 0.75KW
Q:We had a thunderstorm followed by power outage last night, this morning I went to use the water and it slowly went dead.I began by inspecting the pressure tank and pressure control switch, then found the outside water pump breaker was tripped, upon resetting the water was back on!But wait, after about 1-2 minutes of use there was a small quot;POPand smoke from the control switch and the breaker tripped again. It seems now that every time the water pump kicks in I've got a 50/50 shot of the circuit breaker blowing. I'm not sure what to do now, I don't want to keep resetting my pump breaker, we really didn't get that much rain so I don't know what would be causing this issue?Any help would be greatly appreciated.Thanks!
So, you say you have a 50/50 chance of the water pump's breaker popping out when you use it now. I would assume you mean when you've used it enough to make the pump come back on. Actually, I think I'd start by replacing the pressure switch, regardless of which system you have, submersible or above ground, the pressure switch will be where it can be serviced. I really can't think of any reason why a pressure switch would cause a breaker to trip, but at least that way you'd know you've done all you can do. If your system is a submersible you'll have to have a water company come out with a boom truck to pull that pump up out of the ground.
Q:vw tells me the pump is defective, bad water circulation. i noticed the fans did not turn on when it began to overheat. is that irrelevant with the pump being defective? i even drop the car cold(i started the engine and drove) within 10mins it began to overheat, but the fans did not turn on. is it just the pump? the fan switch is new, no fuses are blown. the radiator and fans are less than 2 yrs old. 2000 jetta
The fan switch on that car is in the thermostat housing so it would not turn on. It is very common for water pump to fail on those cars. The cooling fans help keep the water in the radiator cool if you r water pump is bad, and us ally what happens is the impeller falls off, no water is moving from the engine to the radiator.
Q:I want to replace a water pump for my friend. I can't find any books on this car. I'm not sure how to replace this pump. Looking at new water pumps there lookes like 10 bolts, but on my chevy truck there was only 4. I don't know if all holes take a bolt or not, or if I need to take something out before I take the water pump out.Anyone ever changed a water pump on this car? or know what book or website I can look at which will give me an idea.
autozones web site has some good instructions on most popular cars
Q:I have a quot;Rainbow Lifeguard Quiet One 6000external pump that I would like to use on a new chiller for my tank. The pump is rated at a little over 1500 gallons per hour. I'm debating between a couple of chillers, one that has a max flow rate of 1300 gph and another that has a max of 960.I know that you are only supposed to put any valves on the outflow side of the pump and lessening the flow to 1300 from 1500 doesn't seem like it would be that big of a problem, but I was curious it cutting it back to 960 would be hard on the pump in the long run. (I'm leaning towards the bigger chiller as although it may be overkill for my tank, it would let me have a little more water circulation.)
ditto to magic
Q:After the pump has the control box, but also the power distribution box, the control box and the distribution box is not the same box?
What you are saying is not a concept. The function of the control box is to control one or more equipment and to protect the equipment. The function of the distribution box is to distribute the power. The control box is connected to the power box, and the power box may be responsible for several devices at the same time. The distribution box is just one of them.
Q:Water is pumped through a pipe of diameter 13.0 cm from the Colorado River up to Grand Canyon Village, on the rim of the canyon. The river is at 564 m elevation and the village is at 2311 m.(a) At what minimum pressure must the water be pumped to arrive at the village? (in MPa)b) If 4300 m3 are pumped per day, what is the speed of the water in the pipe? (in m/s)(c) What additional pressure is necessary to deliver this flow? Note: You may assume that the free-fall acceleration and the density of air are constant over the given range of elevations.( in kPa)I have tried this over and over but i know B it is 3.75 m/s please help if you know to do this THANKS!!!!!
a) Pressure is the weight of a 1 meter square column of water. The height of the pipe is 2311-564 = 1747 m volume is 1747 m? density of water is density of water at 20C = 0.998 g/cm? = 998 kg/m? mass of water is 1747 m? x 998 kg/m? = 1744000 kg weight of water is 1744000 x 9.8 = 17090000 N Pressure is 17090000 N/m? or 17.09 MP b) Cross sectional are of pipe is A = πr? A = π(.065)? = 0.0133 m? one meter of pipe has a volume of .0133 m? 4300 m? are pumped per day The water in that one meter of pipe has to be changed 4300 / 0133 = 324000 times per day to handle the flow That is 324000 / (24*3600) times per second or 3.75 times per second. Since the section of pipe is is 1 meter, that is 3.75 meters per second.
Q:Water is pumped upwards 4.000 m into a pool. The flow rate of the water is 4.000 L/min and it takes 10.00 minutes to fill the pool. What is the power of the pump?I would appreciate any help that you can give me - this is a question on an upcoming test!
You have the following information: Mass of water delivred = 4*10 = 40 litres = 40kg Height = 4 metres time = 10minutes = 600 seconds Work done = m*g*h Work done = 40*9.8*4 work done = 1568J Poweer = work done / time Power = 1568/600 Power = 2.61 Watts. It seams a very small pump to pump only 4 litres/minute.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords