This Generator powered cooperating with AVL
Model | Engine Model | Rated Power (KW) | Standby Power (KW) | Engine power (kw/r/min) | FUEL | L×W×H (MM) | Weight (KG) |
(L/H) | |||||||
FKS-500 | G6190ZLD | 500 | 550 | 540/1500 | 123 | 4950*1500*2350 | 7800 |
FKS-600 | 8190ZLC | 600 | 660 | 720/1500 | 143.5 | 5200*1650*2350 | 8900 |
FKS-800 | Z12V190B | 800 | 880 | 882/1500 | 164 | 5300*1970*2780 | 13600 |
FKS-900 | G12V190ZL1 | 900 | 990 | 1000/1500 | 205 | 5300*2040*2700 | 13800 |
FKS-1000 | A12V190ZLD | 1000 | 1100 | 1200/1500 | 246 | 6250*2250*2750 | 19300 |
FKS-1200 | BH12V190ZL | 1200 | 1320 | 1360/1500 | 266.5 | 6380*2200*2650 | 18500 |
FKS-1500 | H12V190ZLD | 1500 | 1650 | 1580/1500 | 348.5 | 7880*2850*3200 | 21000 |
FKS-2000 | H16V190ZL | 2000 | 2200 | 2200/1500 | 492 | 9060*2870*3200 | 24000 |
Specifications
This Generator by cooperating with AVL
Model | Engine Model | Rated Power (KW) | Standby Power (KW) | Engine power (kw/r/min) | FUEL | L×W×H (MM) | Weight (KG) |
(L/H) | |||||||
FKS-500 | G6190ZLD | 500 | 550 | 540/1500 | 123 | 4950*1500*2350 | 7800 |
FKS-600 | 8190ZLC | 600 | 660 | 720/1500 | 143.5 | 5200*1650*2350 | 8900 |
FKS-800 | Z12V190B | 800 | 880 | 882/1500 | 164 | 5300*1970*2780 | 13600 |
FKS-900 | G12V190ZL1 | 900 | 990 | 1000/1500 | 205 | 5300*2040*2700 | 13800 |
FKS-1000 | A12V190ZLD | 1000 | 1100 | 1200/1500 | 246 | 6250*2250*2750 | 19300 |
FKS-1200 | BH12V190ZL | 1200 | 1320 | 1360/1500 | 266.5 | 6380*2200*2650 | 18500 |
FKS-1500 | H12V190ZLD | 1500 | 1650 | 1580/1500 | 348.5 | 7880*2850*3200 | 21000 |
FKS-2000 | H16V190ZL | 2000 | 2200 | 2200/1500 | 492 | 9060*2870*3200 | 24000 |
- Q:Hi, I am trying to find a video or text based tutorials for backup generator on internet but i was unable to find a single. i am trying to find complete tutorial of mechanic and how to fine tune generators. hope here anyone knows about it.
- I am generator technician, what specific things are you looking for?
- Q:Hi and thanks for reading.I have a small trailer I am looking for a back up propane generator for.We have wind storms here that knock out power for days on end, about a half dozen times per year, so I'm looking to get some back up electricity, howeverMy lot size is SMALL, so is my trailer. I have a natural gas line, and gas furnace, so I only use about 1500 watts at peak times, so I figure a 3k watt generator will more than cover my needs.SOUND is a huge factor. I have the worst neighbors in the world and I really need something quiet. I'm looking for something with less than 60 ddb.I have seen a lot of propane generators that look good, but I dont know if they can be used with natural gas easily. I think so, but would love to hear if thats true, and they dont have the standby plug feature, which I need to save my fish tank, any know if this can be easily changed by a skilled electrician?Thank you. Any and all help would be greatly appreciated.
- I've seen ones running propane, gas and diesel. The larger units for the power you want normally come in their own enclosure helping to keep noise under control. I've not see one designed for natural gas. No propane ones are not designed for natural gas. The engines have to be designed to handle it so you would need to converse with a place selling these to find out if such are available. If not contact the mfrs for information as to this conversion idea. The enhance quiet you can also build an enclosure around the generator which would limit sound travel from the unit.
- Q:I have a (2306A-E14TAG3) PERKINS diesel engine electric generator, every two hours it turns off by itself. The generator room is well ventilated, opened from all sides, while the exhaust is free for atmosphere without any extensions from the muffler.- 66% used as part load.- Note that this generator is a new generator. ambient temperature is almost 30 degrees celcius, humidity65%.Please help me with this issue, because every two hourse i used to cool the radiator from outside by water! I appreciate your help
- REASONS FOR PERKINS GENERATORS TO SHUT DOWN (according to Ehow): 1. Not putting out correct voltage (too high or too low). 2. Wrong frequency 3. Wrong speed 4. Wrong oil pressure (too high or too low). ///////// Other sources of failure: High current, battery won't charge, speed sensor not working,
- Q:Actually , I heard someone talking about diesel generators and that voltage required, he said two types of diesel generators for electric furnaces in steel industry , the first 16000 voltage, approximately , and the second 32000 voltage I really want to know what does he meant .
- Arc furnaces are normally powered straight through a pylon connected to a transformer and the voltage is normally thousands of volts and normal takes about a hour to melt the bale of scrap steel before poring into a ladle
- Q:i want to put three phase current of two diesel generating sets in only three phase.
- you will need to govern them together, other wise if one is running slightly slower than the other the slower one will act as a motor and not a generator/ alternator. so both must turn at the same rpm speed. then its just wiring configuration delta - delta or Y - Y configurations.
- Q:I have noticed that our kilowatthour meter reads backwards when I use some electrical appliances, please explain why. plgperera.
- are you sure u dont have a diesel generator that sells el. energy back to the grid? jk Is this first time you look at the meter? If so take a look again, should be ok.
- Q:I know they are more expensive.
- Yes. But they also burn much hotter in the SOFC.
- Q:HI FROM NEW ZEALAND.I HAVE A LISTER-PETTER 16 KVA DIESEL 3 PHASE GENSET WITH SINGLE PHASE SOCKET @ 240 VAC. WITH A ITALIAN ELECTRONIC DIAGNOSTICS CONTROL PANEL WITH BREAKERS ETC.WHEN RUNNING A ESAB CADDY PROFESSIONAL 140 INVERTER WELDER @130 AMPS USING 4 MM HARDFACING RODS, ON FIRST STRIKE THE GENSET CUTS OUT AND DIE.WHEN USING A COPPER WOUND TRANFORMER WELDER THE THING RUNS WELL BUT WILL NOT STOP WHEN I HIT THE KEY TO TURN OFF OR EMERGENCY STOP BUTTON.NOTE; THIS IS A STANDBY GENSET IN THAT I JUST PLUGGED IN A WELDER, THE GENSET IS NOT A DEDICATED WELDING GENERATOR.I USED OTHER DIESEL GENSETS PRIOR WITHOUT ANY PROBS.WILL ANY1 HAVE ANY CLUES? REGARDING THIS.THANKS IN ADVANCE.CHEERS CARL GIN
- Does the Esab welder have high frequency? If so the high freq. is feeding back into the generator and frying the electronics. You may need to have the generators repaired. The only way to prevent damage is to turn the high freq. off, or drive an earth ground as close to the welder as possible and you have to run a wire to your grounding clamp to this ground and the machine ground needs to go to this also. You have to get the high freq. out of the circuit as quick as possible. (I have a Hobart Champion Fabshop that is notorious for this.)
- Q:I know that various types of locomotive's produce different amount of horse power. Here's the question: A single locomotive (any type) about what would be the average speed it could gain in 0 to 4 seconds on take off. Any smart A** answer will be reported for abuse, Thank you.
- Hello Brian; From my experience I would say anywhere from 15-20mph. 28 years of railroading. Switch engines don't have to spool up to start, whereas road engines rev up a lot before moving. junkman
- Q:I am build a 40KVA permanent magnet generator for diesel engine. the customer request the voltage is DC 28V after an rectifier. may be this 28V dc charge for the battery. can someone help me how much AC voltage should be output by the permanent magnet generator?permanent magnet generator----AC ???V----rectifier---28VDC---charge to battery.
- In AC side connect a series high current Choke with less no of turns take the out put use a High current bridge Diodes with suitable heat sink.For regulating out put ,In the series choke place a Dc winding that can be excited by a separate dc circuit, Increase saturation will give same voltage decrease excitation will give drop in voltage.It is like magnetic Amplifier.Set the out put voltage with pre set point or a regulating circuit.I have given rough Idea If you want further detail PM me (This only cheapest method unless you have use thyristor or others to con troll may be expensive)
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Similar products
New products
Hot products
Hot Searches
Related keywords
You Might Also Like