Cummins Engine Diesel Generator 120kva 220v 380v 400v
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 1000 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Low-noise 100kw Cummins diesel generator 50hz or 60hz
Briefe performance of silent diesel generator set
1)High quality, steady and reliable performance
2)Blow 71dB at 7 meter
3) Perfect Maneuverability
4) Wide Application
Engine:
Manufacturer | CUMMINS | |
Model | 6BTAA5.9-G2 | |
Cylinder and cycle type | 6 cylinders in line, 4 strokes | |
Aspiration and cooling | Turbocharged and after cooled | |
Displacement | 5.9 L | |
Bore×Stroke | 102×120 mm | |
Compression ratio | 17.5:1 | |
Rated speed | 1500 rpm | |
Governor | Electronic | |
Oil capacity | 16.4 L | |
Prime power | 120kW | |
Standby power | 132kW | |
Fuel consumption | 29.4L/H (100% Load) | 22.4L/H (75% Load) |
Coolant capacity | 9.1 L | |
Start system | DC 24V |
Alternator Specifications:
Manufacturer | STAMFORD |
Model | UCI274E |
Type | Single bearing,4-pole,AC brushless and self-exciting |
Frequency | 50 Hz |
Power Factor | cosΦ=0.8 |
Phase | 3 |
Voltage | 400/230 V |
Capacity | 100kW/125kVA |
Insulation class | H |
Protection class | IP23 |
Elevation | ≤1000m |
Control system:
Optional: DSE or Smartgen
Manufacturer: SNARTGEN
MODEL: HGM6120KC
HGM6120KC Control System is mainly used in generating supervising and control of land type diesel generator set and the switching between diesel generator set and city electricity supply. It is combined with digitalization, intelligence and network and capable of generator start and stop, generator data supervising and testing, protection alarm, city electricity supply quality supervising and starting generator automatically when power failure happens or city electricity supply is beside the set point.
Dimensions and weight:
L: 2100 mm | L: 3000 mm | ||
W: 750 mm | W: 1300 mm | ||
H: 1250 mm | H: 1250 mm | ||
Dry Weight: 1560 kG | Dry Weight: 1760 kG |
- Q: the foreign motor shows 380 volts 3 phase. I have 480 volts 3 phase
- no, obviously the voltages are different, and 480 volts will burn it out. Also, the frequencies are different. .
- Q: Speed control method of AC motor
- The AC motor speed regulating method is just the opposite to the direct current motor speed regulation method. The motor has the advantages of simple structure, little inertia, convenient maintenance, operation in harsh environment, easy realization of large capacity, high voltage, high speed, and low price.
- Q: how do ac motors work? how do airconditioners work?
- thats a long talk.simple way to put it. A/C work by taking hot air from the room and putting it outside. (hot will always travel to cold). hot air gets taking away by the inside coil. then the compressor super heats the refrigerant so its hotter than the out side.( 10+ most of the time). the outside motor blows air across the coil. then refrigerant cools down again and repeats intill the inside is at it set point. If you want more detail on how it work go to this web site I found below.
- Q: I have a centrifugal blower, which probably use a permanent-split capacitor motor(it has 3 wires, and 1 10uF capacitor). Not long after I turn on the motor, its humming sound increases, as if it's speeding up. For fear it's going to explode, I turn it off at this stage. Both the motor and capacitor feels hot. What can be wrong with the blower?
- An AC induction motor runs at one speed only. Three wires is a curious claim, since most PSC uses two. If three terminals are present on a PSC, a small Cap is used on the winding of higher resistance. Split phase motors use start, run, and common with a start relay to disengage start promptly. Overheating is a sign of a start windings failure to disengage. Check the manufacturer's website for a wiring diagram and instructions.
- Q: Why asynchronous motor AC excitation, rather than DC excitation?
- Synchronous motor is also a kind of AC motor. Mainly used for generators, motors can also be used, generally used for larger power, speed does not require the adjustment of production machinery, such as large water pumps, air compressors and mine fans. In recent years, due to the development of permanent magnet materials and electronic technology, micro synchronous motor has been more and more widely used. One of the characteristics of synchronous motors is the steady running speed, N and stator current frequency f1 has a strict constant relationship, that is, n=60f1/p=n0 synchronous motor speed n and rotating magnetic field speed N0 the same. The name of "synchronization" comes from here. The stator of a synchronous motor goes without saying that the general rotor coil must be energized to keep it in sync with the stator. (the rotor of the micro synchronous motor can be made of permanent magnetic steel.)Asynchronous motor is different, the stator winding energized to generate rotating magnetic field, in the rotor to generate induction current, so that the motor rotation. Structure than synchronous motor simple
- Q: The original, and two replacement, fan motors in the outside (compresser) unit of my Miller central air conditioner system all made a loud noise when wet. At first, I thought it was a bad motor, but a replacement didn't help for long. The second replacement worked a day, but the next day was very noisy.I finally traced the problem to one of design. The motor is open in the bottom. When it rains, water hits the fan under the motor and gets splashed up and into the motor. When there is water in the motor, it gets extremely noisy, sounding like a diesel truck motor.There is no question that this is the problem. On a dry day, when the motor is quiet, if I spray water up into the motor (yes, I switch it off first) and then start up the unit, the motor gets noisy.Can I simply replace the motor with a sealed unit of the same power, shaft size, RPM and rotation and solve my problem?Has anyone ever seen this problem before? Is there an easier fix?
- yes i have seen this problem and it was because the motor wasnt the proper motor for the unit.. nearly all condenser fan motors are totally enclosed..or on some old units if the motor had openings on the bottom of the motor there should have been a water slinger that was larger in diameter than the motor to prevent water from being blown or splashed into motor....the easiest fix is to buy a water slinger and install it between your fan blade and your motor...
- Q: The original fan motor had 1100 rpms and the new one is 1075 could this be the reason why the fan motor keeps quot;amping outquot; after a minute of running or is it something else.
- The speed is not a problem. Did you replace the run capacitor? That is what it sounds like. If the capacitor is good check the wiring to make sure it is right. Make sure the fan is spinning the right way.
- Q: Soybean milk machine AC motor or DC motor is good?
- With a special fragrance, and slightly stimulated; slightly sweet, and accompanied by stimulating spicy taste. Flammable gas whose vapors can form explosive mixtures with air and can be miscible with water at any rate.
- Q: I will be really happy enough if this answer is answered more reasonably in a simple explanation. What is the real difference between a DC and a AC motor? I know about the alternating and the direct current. One flows in reverse ad the other in one direction. But that's not clear enough. Please help me out.
- A good explanation requires diagrams which can't be included here. It is important to understand that the direction of the force on a wire in a constant magnetic field depends on the direction of the current. Reversing the current direction reverses the force. The force's direction must change each half-rotation to keep the motor turning. This force-reversal can be achieved by: - in a DC motor using a split ring commutator and - in an AC motor having two slip rings and using the fact that AC reverses direction each half-cycle. See link.
- Q: What is the maximum speed of a three-phase AC motor?
- Level two is close to 3000 rpm, does not include ultra high speed, ultra high speed has 6000
Send your message to us
Cummins Engine Diesel Generator 120kva 220v 380v 400v
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 1000 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords