WQ series Designed Sewage Centrifugal Pumps

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
200 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

1. Product Introduction

WQ series submersible sewage pump is mainly used for municipal work, industrial building, hotels, hospitals, civil air defense, mines, etc. It can be widely used in transfer waste water, rainwater and living water etc. which contains solid grains and various long fibers CNBM WQ series sewage submersible pump have many advantages, such as, hi-efficiency, circumvolution proof, blockage free, auto-coupling, hi-reliability and auto-control, etc.

 

2. Technical Performance

Discharge diameter: 50~600 mm

Capacity: 10~8000m³/h

Head: 5~60m

Power: 1.5~315kw

Diameter of pass solids: 20~145mm

 

3. Operation Condition

1). Rated Voltage: 380V(660V), Frequency: 50Hz, 3-phase AC.

2). Temperature of medium under 40ºC.

3). PH value: 4~10.

4). Volume ratio of solid in medium below 2%.

5). Density of medium should be lower than 12000kg/m³.

 

4. Structure Characteristic

WQ series submersible sewage pump is equipped with status indicator and protection device to ensure for pump safe and reliable operating.

1). The unique cable airproof is adopted, avoid leakage of cable.

2).  Heat protector in stator assure of operating life of the motor.

3).  The pump adopts outer recycling cooling design with motor power more than 18.5kw, which can keep the pump operating safely under the lowest water level.

4).  A floating switch is installed at the bottom of motor chamber to protect the mechanical seal in the motor side.

5).  The oil-water probe is installed at the up end of the oil chamber between pump and motor that can protect the mechanical seal in the side. If leakage occurs, the system will signalize and start protection.

6).  Adopt perfect mechanical seal, the sealing material adopt tungsten carbide, silicon carbide and hard metal alloy, which can prevent the water from entering into the motor, and keep the operating reliable and safety.

7).  The auxiliary impeller can balance the pressure outside of the mechanical seal, prevent the water entering into the oil chamber and prolong the life of the motor.

8).  Unique impeller design, wide passage allow large solid and long fiber passing through freely, it features non-clog, convolve-proof and good passing ability.

9).  The changeable wearing ring is installed between the impeller and the volute to keep the optimum operation conditions.

 

5. Impeller Design Characteristics

For the feculence pass freely, it must be widen the flowing passage of impeller, for the big pump, can used for double-vane, or three-vane, for the small pump, it used for single(double) flowing passage, like a bent pipe has same section, it has a good passing characteristic, avoid stop, convolve caused by slowing current possibly. The especially flowing passage of impeller, cooperate with logical volute, made the paper, soft goods, garbage bag and other material in sewage can passing freely and the pump have no vibration in the course of running-in and load through the impeller balance between dynamic and static state.

 

6. FAQ

1). How long is your warranty?

Unless otherwise expressly authorized in writing, by specifying a longer period or different conditions, CNBM states that, for a period of twelve (12) months from delivery date, all Products supplied are free from defects in materials and workmanship, and conform to the applicable specifications. Either the delivery documentation or the invoice must be provided to prove delivery date. In absence of such documents, the production date appearing on the product label may suffice.

2) How can I get trained on CNBM products?

Yes, we provide training courses in our factory (products, general and specific pump technology, hydraulics, and practical applications). Please consult your sales manager or get in touch with our headquarters for more information.

3) Are your pumps cheaper than those of your competitors?

CNBM aims to give its customers the highest standards of quality and service and delivery times, all at a reasonable price.

4) Do you have self-priming pumps?

Yes, our product portfolio also includes two ranges of self-priming pumps: self-priming electric pumps and self-priming side channel pumps.

5) Is it really necessary to fit a bleed valve for the boxes?

It is always best to have a bleed valve as the gas produced by the fermenting sewage is potentially hazardous.

6) If I increase the power of the motor, must I also increase the power of the inverter?

You must select the size of converter that allows maximum absorption of the electric motor.



WQ series Designed Sewage Centrifugal Pumps

WQ series Designed Sewage Centrifugal Pumps




Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:what can i use for a car water pump gasket?
Water Pump Gasket
Q:Water pumping work problem?
The pump will not have to work until the water drains by gravity to the level of the spout. Then, Work = Weight of water * Height of lift Find the distance, d, of the center of mass for the remaining water in the bottom 2 m of the sphere. The height of lift will then be 2m - d. The hardest part is finding the distance d to the center of mass. I don't remember how to do that.
Q:1999 Plymouth Breeze Water Pump?
An engine scan will not tell you your water pump is leaking. Take it some place that knows what they are doing.
Q:How to check a water pump on a 1998 Dodge Dakota V6?
to answer your question directly, you can check a water pump the same on any car. water pumps have whats called a weep hole there is a small hole that is designed to leak coolant when your water pump seal goes out. find the pump and see if there is a trail of white from this 'weep hole' then yes your pump is bad. if not, i dont know the layout of the hoses for your car so i couldnt diagnose it for sure. but check your water pump for the signs i gave you. its a tell tale sign
Q:What's the submersible pump?
Centrifugal pump, a general motor and pump body is one, you can pump the whole pump into the water
Q:who can recommend me some good water pumpS?
Water pump. ( Pond ) Sump pump. ( Flood prevention ) Auto water pump. ( Radiator ) What is the specific purpose of the pump.
Q:Is it the water pump?
if the top radiator is collapsing then the radiator is clogged up ! i doubt it,s the water pump ! try this ! once the engine is hot, shut it down and feel the radiator fins next to the fan ! if you feel cold spots then the radiator is clogged in some places ! flush out the whole cooling system ! i had a ford truck that did the same thing until i bought a new radiator !
Q:im changing my water pump on 97 cadillac need help?
The tool you need is the kent moore design one. it has a bracket that bolts on and helps hold that socket that you call it snug against the pump..one other thing look at the new pump to determine the direction it loosens because i do not remember,also we have only one tool and its worked on all northstar engines so far
Q:What is the defection of water pump
The structure of the water pump and water pump water.Because: when the pump head exceeds the rated head, pump current will increase, the water discharged from the pump impeller, back to the inlet of water from between the impeller and the casing exceeds the rated value, if it is a high lift pump, clearance between the impeller and the pump shell is very small, the current increases with increasing lift, current exceeds the rated value too soon many motor will be burned.
Q:Water pump "rated lift: 6m" what do you mean?
Lift refers to the weight of fluid per unit weight after the pump, the pump is an important working parameter, also known as pressure head. Simply stated: rated lift 6M refers to the rated operating conditions of the pump, the increase of energy 6M water column height. Here's an example to help you understand:Example 2-1 the head of a centrifugal pump is now measured. The refrigerant is 20 DEG C water, the measured flow rate is 60m^3/h, vacuum pump inlet meter 0.02Mpa, outlet pressure gauge readings for the 0.47Mpa (g), the two known table between the vertical distance is 0.45M if the suction pipe of same diameter and pipe pressure pump, calculate the pump head.Solution:Check the water density at 20 centigrade 1.0*10e3kg/m3,H=0.45m (1Mpa approximately equal to 100 m water column)P exports =0.47Mpa (0.47*100 m water column, =47 m water column)P imports =-0.02Mpa (0.02*100 m water column, =2 m water column)P is the density of the liquidH=h+ (P -p / P g=0.45+ export import) (0.47*10e6- (-0.02*10e6)) / (10e3*9.887) =50.5m (water)

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range