• Standard Hot Dipped Galvanized Iron Wires System 1
Standard Hot Dipped Galvanized Iron Wires

Standard Hot Dipped Galvanized Iron Wires

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Commercial Galvanized Steel Wire

(1) Quality : Meet GB/T 343 standard and other requirements of relevant standards .

(2) Zinc Coating: Meet GB/T 15393 standard and other requirements of relevant standards .

(3) Raw Material : Wire rod ——1006 , 1008 , 1018 , Q195 , etc, and zinc with 99.995% purity.

(4) Tensile Strength Range

Size (mm)

Tensile Strength (mpa)

0.15-1.60

290-550

0.65-1.60

400-550

1.61-6.00

400-1200

(5) Application : Used in wire mesh , artware , metal hose , binding for agriculture and construction , etc.

(6) Packing

Size (mm)

Coil Size

Spool Packing

Big Coil Packing

ID (mm)

OD (mm)

0.15-0.26

6 inch

1-14kg/spool

0.27-0.60

8 inch

1-100kg/spool

0.61-1.60

12/14/16 inch

1-100kg/spool

250-400

400-770

1.61-6.00

14-500kg/spool

450

800

508

840


(7) Zinc Coating

Meet GB/T 15393 standard.

Size (mm)

Weight of Zinc-Coating ( g/m2 )

A

AB

B

C

D

E

F

A1

B2

0.25

30

20

18

>0.25-0.40

30

25

20

>0.40-0.50

30

20

>0.50-0.60

35

20

>0.60-0.80

120

110

40

20

>0.80-1.00

150

130

45

25

>1.00-1.20

180

150

50

25

>1.20-1.40

200

160

50

25

>1.40-1.60

220

180

50

35

30

>1.60-1.80

220

180

70

40

30

>1.80-2.20

230

200

80

50

40

>2.20-2.50

240

210

80

55

40

>2.50-3.00

250

230

90

70

45

>3.00-4.00

270

250

100

85

60

30

>4.00-5.20

290

270

110

95

70

40

>5.20-6.00

290

270

245

110

100

80

50


Q: my radio was stolen i'm trying to put in a old radio in but when someone stoled my radio they cut the wires so now i can't tell what go,s where can someone please help? it's a ford f150 pu trck w/ 4 speakers i just need the wire color codes to hook-up,plus thy stole the manal to the trck too. please help.ty
2003 Ford F150 Truck Car Radio Stereo Wiring Diagram Car Radio Battery Constant 12v+ Wire: Light Green/Pink Car Radio Accessory Switched 12v+ Wire: Black/Violet Car Radio Ground Wire: Black/Green Car Radio Illumination Wire: Light Blue/Red Car Stereo Antenna Trigger: Blue Left Front Speaker Positive Wire (+): Gray/Light Blue Left Front Speaker Negative Wire (-): Tan/Yellow Right Front Speaker Positive Wire (+): White/Light Green Right Front Speaker Negative Wire (-): Dark Green/Orange Left Rear Speaker Positive Wire (+): Orange/Light Green Left Rear Speaker Negative Wire (-): Light Blue/White Right Rear Speaker Positive Wire (+): Orange/Red Right Rear Speaker Negative Wire (-): Brown/Pink
Q: I bought a single pole dimmer switch to install in my dining room and when I took the old switch out nothing looked right. There are two wires which were joined together by another single wire which was attached to the top screw. There was another single wire (I believe the ground wire) attached to the bottom screw. I disconnected the first two wires and attached them separately to the black wires on the dimmer and attached the ground wires together. It didn't work. I've tired several different times with no luck. I put the wires back the way they were and attached them to the old switch and they no longer work ether. Help! How can I fix this problem? The old wires appear to be a very thick copper covered in black plastic and cloth.....
How To Install A Dimmer
Q: How doI wire a ceiling chain light to wall switch? I want to stop using the chain to turn the light on and off. I hane already installed the wall switch and the wiring in the box but not sure how to connect the wiring in the box to the ceiling light wiring.
Before you do anything, turn off the power. Sometimes people will wire up switches hot, but they know what to touch and what not to touch. You should not take that risk. There will be two power cables coming into the box, one from the power source and the other to the ceiling light. Each cable has a black wire, a white wire, and a bare copper wire. Connect all the white wires together with a wire nut. Connect all the bare wires and an extra piece of bare wire together with another wire nut. Connect the extra piece of bare wire to the green screw terminal on the switch. Connect the black wire from the power source to one brass screw terminal on the switch. It doesn't matter which one you use. Connect the black wire from the ceiling light to the other brass screw terminal on the switch. Don't screw the switch into its box yet. Turn the power back on. Test the switch, being careful not to touch any wires while doing so. After it works, turn the power off again and screw the switch into t
Q: ceiling fan connections which wire goes where?
THe black wire is hot (live) The white wire is netural (return path) The green wire is ground (connected to metal juction box) the red wire is use in connecting three-way switch
Q: What's the thickness, or measurement for the last or thickest wire?
they change your wire according to how much your teeth have shifted around, so it just depends. the ortho needs to adjust the size of the wire due to your teeth straightening out and making sure the wire(s) are at a correct length. its really not that thick of a wire, so don't worry about it. :D
Q: the plug only has room for black,red,ground wire.. what do i do with the white wire
You can't. You need a 4-wire receptacle to use with 4-wire cable. That is the only to wire this circuit to code. You will need to replace the cord on your appliance with a 4-wire as well.
Q: what if I use a 100 amps.main braker to wire my range and dryer
Whoa there! What you're describing is a 120 volt outlet (U.S. Canada). Every dryer I know of operates from 220 volts. For a three-prong, 220 volt plug, you should connect the black to one of the hot terminals and the red wire to the other hot terminal. The white wire, which is neutral, would go to the common terminal. The outlet box you describe is a 120 volt box. . .it just won't work! If you're operating a 220 volt dryer from 120 volts, you're asking for trouble. Besides, for a 120 volt outlet, you've got the connections all skewed. Here it is as looking at the outlet from the front: Black (hot) to small blade (brass screw), White (neutral) to large blade (silver screw), Copper (ground) to green grounding screw. You may have to run a 220 volt line from the dryer to a new breaker in your electrical service panel. I strongly suggest you leave this to a licensed, qualified electrician.
Q: i need to connect a new bathroom light/fan combo to existing wiring. Existing wiring is black/white/red/copper. The new fixture wiring is black/blue/white/white. Thanks
Steven F has nailed it. I'll add that the fixture probably has a green screw: connect the bare copper wire to that.
Q: im installing an amp and i have no clue what to do with thw power wire.... I read to cut open my steros power wire (usually the blue) and wrap my power wire around it... I found the blue wire but there was a tag... Caution Remote output only... This is not the wire for power supply. please connect this wire to the remote for the amplifier... Does this mean i just connect this wire directly to my amp?
ok wait hold up. so the only wire that should be hooked from the amp to the headunit is your speaker wires, remote turn on wire, and your rca cables. ....What you need to do is get the power cable(usually red) run it from positive on the battery to the POS on your amp. next put your ground wire from the GND on the amp to bare metal on your cars chasis.
Q: i have a 97 chevy blazer. My fuel pump went so i purchased a new one. i did not know that the company changed the wiring on the fuel pump..all the wires are 2gether in the wiring harness and all i have to do is cut off the old harnss and wire the new one in its place. Im not sure exactly how to wire it. What do I do? do i just strip wires and twist them or what?
trace down old wires from pump / sending unit there will be one wire that goes to both the pump and sending unit....... that is ground ....mark old wires before cutting ....... then hook to same on new pump

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches