Factory price china yuchai diesel generator sets 310kw
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 300 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specifications
open type dioesel generator with yuchai enginee
1) Factory direct sale
(2) CE, ISO9001 quality
Power range | 18-650KW |
Engine | All series powered by Yuchai engine |
Alternator | All series owning alternator options of Stamford/Marathon/ENGGA |
Controller system | Hanging control box, automatic control module Smartgen HGM6310 |
Base frame | International channel steel welded base, inbuilt composite damping system; sandblast, acid-washing, antiseptic treatment |
Radiator | Standard genset-joining radiator of 40 °C ambient temperature |
Diesel generator Powered by Yuchai Engine,which yuchai is a large state-owned enterprise and a Nasdaq listed company in USA (NYSE:CYD). Its main business covers diesel engine, contruction machinery, vehicle parts. The engines produced by Yuchai include series YC6G, YC4G, YC4E to which American technology applied, series YC6A, YC6B, YC6J, YC4B, YC4D, YC4F, YC4W to which German technology applied, and YC6M series in which world top technology integrated, totally 12 series.
YUCHAI Series | Power(KW) | Power(KVA) | Jichai Engine Model | Cylinder NO. | Fuel consumption g/kw.h | DimensionL*W*H | Weight KG |
FKS-Y310 | 310 | 200 | YC6G245L-D20 | 6 | ≤195 | 2500*970*1500 | 2300 |
- Q: I am contemplating on getting a full house generator and need some feedback from you all.l. What is the best brand for quality and durability of a generator and what hp would I needThe house is about 2,000/sq ft, central A/C heat, all electric at the moment with the usual appliances.2. I want to connect permanently to breaker box for automatic turn on and will need fuel for it.3. In light of today's economy and potential collapse if one is in survival mode, is it better or cheaper to have butane or propane ?Also what size tank would need to buy, and how big is reasonable ? to last a good while or as needed.I am totally electric right now including water well pump so when power down, I'm sunk!!
- With electric heat, you're into a large generator. 'Automatic on' means a transfer switch generator control panel. If you're thinking about 'survival mode' diesel is your best fuel option. (More widely available, less tech. support for refueling, and stores well.) You might consider an engine heat capture system for efficiency in winter conditions. You probably need about 20-25KVA to handle full load with heating. (That's only a 'guestimate, DO do the math before you select a unit.) This won't be cheap.
- Q: How to convert kVA (kilo-volt Ampere) to kg/h (kilogram per hour) for diesel generator set (genset)? I want to know the relation about the energy produced (kVA) to the fuel that used (kg/h) in the genset, either it used more diesel fuel or not. i.e the kVA amount produced is 106kVA and the rpm is 1500rpm
- Man, your question is really cryptic. I assume that you are trying to relate kg/h (kilogram per hour) of (maybe fuel) into the engine with kVA (kilo-volt amperes) out of a generator that it may run. There is no conversion factor. But there are some rules of thumb that some can make, based on the size and service of the engine. But you did not provide even that scant information, either.
- Q: i am going to buy a second hand generator which is 108kva diesel enginehow can i test it so i know it starts but also is capable of running around 80-100kvai want to make sure it is strong and still working and not that it just startsplease help thankssam
- You need to load test it and operate it to test both the power output of the diesel, and the condition of the generator.See if you can rent the use of a salt box to load test the generator.or see if the seller will allow you to hook it up to your equipment at your place and see if it will carry the load under real world test conditions. Note, a marine electrical shop,or motor rewind facility should have a salt box. Call and ask them
- Q: and diesel generator and ATS that switches between two electrical sources ??
- There may be no difference. It will depend on the application. For example, if I specified an ATS that had the proper voltage and current capacities, the only other item of concern would be to determine if the transfer would be a make before break or a break before make type of transfer. In a make before break, it would mean the sources would be placed into parallel operating condition before one of the sources was interrupted. This would require the ability to synchronize the sources. Which means the frequency, voltage and phase relationship of the sources must match before they are placed into parallel service. On a break before make switch, usually only phase rotation and approximate voltage levels are of concern. Hope this helps, Newton1Law
- Q: Hi, i have a peugeot diesel conected to an 8kw alternator via a lay shaft engine 2275rpm alt 1500rpm at 2250rpm engine produces max torque 70lb ft, alt should only need 33lb ft. under heavy load engine allmost stalls. I think i need avr control? Can you help with advice and componants? Many thanks Andre
- The alt is what RPM you will set the engine atMost 120-240 volt are 50 HRX and run at 1800or 3600 so if it's the 3600 back end your using the wrong engineUnless you use a pulley and belt to get the correct RPMMY 8K Diesel marine ONAN direct drive 3cyc runs at 1800 Rpm If your over loading the genset than no engine will workwhat is the load your pulling as 8K is 80 amps Max single 240V or 40 amp double 120V
- Q: Does one gas power station make a lot of energy? Or would you need more than one of them? :D X
- One power station will have many gas turbines and generators. This depend upon the availability of gas,power consumption in that area,pollution problems etc.
- Q: i want to put three phase current of two diesel generating sets in only three phase.
- Yes you can, just make sure the connections are grounded first!
- Q: i need three ways to save the amazon rainforest and explain how they will work? thanks
- Hi, okorder
- Q: I have been given a cheap diesel generator made from china. It starts alright, but seems to be reving very high and poping and spitting until it has ran for a while. It surges some times as well. I don't really like it much and haven't used it to power anything other then to load test it a bit. I have checked the motor and all it has is a simple governor on it with no adjustments? I am not sure even where to start adjusting anything on this. Any body have one of these and same problem? Please I was given it, I would like to get a little service out of it , not just junk it Fuel, oil, air filter are all new.so? help?
- So what did you want to do with this engine? It sounds like a stationary engine used to power a generator or pump or similar application at a constant RPM.
- Q: I have two deisel engines and two tank feeds, how can I connect the genset (4KVA) . I am conerned when the engines are idling or even running they will start the genset. I do not want to put an extra tank.Thank you
- If your tank has another port on it for a fuel line that is where you hook up. If not go to the supply line at the tank and put in a T fitting and then a shut off valve for each engine. Run the supply line to the generator from that T. You will also need a return line from the generator that you can T into at the return line from the engine at the tank. Many people that convert from gas to diesels run into these same problems. Often a fitting is made up that is put in the fuel fill line to allow for the return line. The generator supply and return lines will be smaller then the engine fuel lines. Running the engines will not cause the generator to start.