• Corrosion protection armoured computer cable System 1
  • Corrosion protection armoured computer cable System 2
  • Corrosion protection armoured computer cable System 3
  • Corrosion protection armoured computer cable System 4
  • Corrosion protection armoured computer cable System 5
  • Corrosion protection armoured computer cable System 6
Corrosion protection armoured computer cable

Corrosion protection armoured computer cable

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
1000000meters m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Corrosion protection armoured computer cable

Product introduction:

The product is low capacitance, low inductance, distributed type instrument signal cable of perfect shield and anti-interference performance, it can reliably transmit feeble analog signal and digital signal, and its explosion-proof safety is prominently better than general DCS cable and control cable. The product is widely used to transmit auto-control signals in the places where exist explosion danger such as chemical, power, coal gas engineering and mine, etc, or other places where require higher explosion-proof safety.

Executive Standard

  Q/AHXYLY02-2009 equivalent to British standard BS5308

Operational Performances

1. Rated AC voltage: U0/U 300/500V

2. Max. working temperature of conductor core: 70°C, 105°Cand 135°C

3. Lowest ambient temperature: for fixed laying:-40°C,non-fixed laying:-20°C

4. Allowed minimum bending radius of cable: for non-armored cable, not less than 6 times of cable outer diameter; for copper tape shield or annoyed cable, not less than 12 times of cable outer diameter.

Main Technical Data

Item

Unit

Data

Working capacitance

PF/m

≤80

Capacitance unbalance

PF/m

≤1

Distributed inductance

µH/m

≤0.6

Inductance/resistance

µH/Ω

≤25

Induction voltage (interference magnetic field 400A/m)

mV

≤5

Static induction voltage (static voltage 20kV)

V

≤1

Radiation field penetration (interference field 200MHz, 120dB)

dB

≤66

Insulation resistance at 20°C

MΩ.km

≥5000

Test voltage

V/1min

2000

Flame-retardant character (test to be performed in terms of GB/T12666.5-1990)

Type A

Basic Types and Descriptions

Type

Designation

IAJYPVP

Copper-core PE insulated, PVC sheathed, woven copper wire separate shield, general shield,intrinsically safe DCS cable

IAJYPVRP

Copper-core PE insulated, PVC sheathed, woven copper wire separate shield, general shield,intrinsically safe DCS flexible cable

IAJYP1VP1

Copper-core PE insulated, PVC sheathed, tinning woven copper wire separate shield, general shield, intrinsically safe DCS cable

IAJYP1VRP1  

Copper-core PE insulated, PVC sheathed, tinning woven copper wire separate shield, general shield,intrinsically safe DCS flexible cable

IAJYP2VP2

Copper-core PE insulated, PVC sheathed, copper tape separate shield and general shield, intrinsically safe DCS cable

IAJYP3VRP3

Copper-core PE insulated, PVC sheathed, aluminum/plastic compound tape separate shield and general shield, intrinsically safe DCS flexible cable

IAJYP1VRP3

Copper-core PE insulated, PVC sheathed, tinning woven copper wire separate shield and aluminum/plastic compound tape general shield, intrinsically safe DCS flexible cable

IAJYP1V22RP3

Copper-core PE insulated, PVC sheathed, tinning woven copper wire separate shield and aluminum/plastic compound tape general shield, steel tape armored intrinsically safe DCS flexible cable

IAJYP1V32PR

Copper-core PE insulated, PVC sheathed, tinning woven copper wire separate shield and woven copper wire general shield, small-gauge steel wire armored intrinsically safe DCS flexible cable    

ZR-IAJYPVP

Copper-core PE insulated, 105°Cflame-retardant sheathed, woven copper wire separate shield and general shield, intrinsically safe DCS cable

ZR135-IAJYPVRP

Copper-core PE insulated, 135°Cflame-retardant sheathed, woven copper wire separate shield and general shield, intrinsically safe DCS flexible cable

ZR-IAJYP1VP1

Copper-core PE insulated, 105°Cflame-retardant sheathed, tinning woven copper wire separate shield and general shield, intrinsically safe DCS cable

ZR135-IAJYP1VRP1

Copper-core PE insulated, 135°Cflame-retardant sheathed, tinning woven copper wire separate shield and general shield, intrinsically safe DCS flexible cable

ZR-IAJYP2VRP2

Copper-core PE insulated, 105°Cflame-retardant sheathed,copper tape separate shield and general shield, intrinsically safe DCS flexible cable

ZR135- IAJYPVRP3

Copper-core PE insulated, 135°Cflame-retardant sheathed, woven copper wire separate shield, aluminum/plastic compound general shield, intrinsically safe DCS flexible cable

ZR-IAJYPV22RP1

Copper-core PE insulated, 105°Cflame-retardant sheathed, woven copper wire separate shield, tinning copper wire general shield, steel tape armored intrinsically safe DCS flexible cable  

ZR135- IAJYP1V32RP

Copper-core PE insulated, 135°Cflame-retardant sheathed, tinning copper wire separate shield, woven copper wire general shield, small-gauge steel tape annoyed intrinsically safe DCS flexible cable

1.Code and definition

Item

Code

Definition

Flame-retardant

character

/

ZR

ZR-135

Non flame-retardant that can be omitted

General flame-retardant

135°C flame-retardant

Series code

IAJ

Intrinsically safe explosion-proof DCS cable

Insulation material

Y

V

VD

E      

PE

PVC

Low smoke and low halogen PVC  

Low smoke and halogen-free polyolefin

Shield material

P

P1

P2

P3

Woven copper wire shield

Tinning copper wire

Copper tape

Aluminum/plastic compound tape

Armor material

22

32

Steel tape armor

Small-gauge steel wire armor

Heat-resistant grade

70

105

135

Max.working temperature is 70°C,can be omitted

Max.working temperature is 105°C

Max.working temperature is 135°C

Conductor type

A

B

R

Single-strand conductor

7-strand twisted conductor (type A&B are marked after specification)

Multiple-strand flexible conductor

Specification

Pairs (or groups) x cores of each pair(or group) x conductor core section mm2

Pairs (or groups): 1,2,3. .. .24

Core of each pair (or group): 2, 3

Conductor core section s: 0.5, 0.75, 1.0, 1.25, 1.5, 2.5 (mm2)

Note: Intrinsically safe cable required to be high-temperature-resistant, oil-resistant and acid/alkali corrosion-resistant, its types and materials can be referred to relevant items of computer cable. Based on the above-described type description for intrinsically safe explosion-proof DCS cable, different combinations can be selected to meet requirements.

SpecificationSize

1.IAJYPVP, IAJYP3VP3,IAJYP2VP2, ZR-IAJYPVP, ZR-IAJYP3VP3, ZR-IAJYP2VP2(Twin type)

Cont table


Note: The outer diameter of armored cable could add 4.0mm

2.IAJYPVP, IAJYP3VP3,IAJYP2VP2, ZR-IAJYPVP, ZR-IAJYP3VP3,ZR-IAJYP2VP2(Triplet)


Cont table


Note: The outer diameter of armored cable could add 4.0mm

FAQ

Marking Examples:

Example 1: Intrinsically safe DCS flexible cable selectingcopper-core PE insulation, PVC sheath, woven copper wirepair shield and general shield, nominal section of conductorcore is 1.0mm2, 19-strand twisted conductor with three 3-wire groups, can be expressed by:IAJYPVRP 3 x 3 x 1.0

Example 2: Intrinsically safe DCS cable selecting copper-core PE insulation. 105°Cflame-retardant PVC sheath.aluminum/plastic compound pair shield, woven copper wire general shield, nominal section of conductor core is 1.5mm2, 2pairs: Conductor-core applies single-strand copper wire: ZR-IAJYP3VP-105 2 x 2 x 1.5(A)

Conductor-core applies 7-strand twisted wire:

ZR-IAJYP3VP-105 2 x 2 x 1.5(B)

Packaging & Shipping

 

Packaging Detail:

international wooden drums or according to your   requirement.

Delivery Detail:

In 15days or as the quantity   you required


Our Services

1.Free samples can be afford if needed.

2.2 years warranty after selling


Company Information






Q:I need to know if the power light on the amp will turn on if I don't have the RCA cables hooked up or if you have to have them hooked up just to get power to the amp? I was just wondering because I just hooked up an amp and I can't get the power to come on, and I'm pretty sure the power, ground, and remote wire is hooked up good, it's the RCA cables i'm thinking is messed up, but would the power light come on even if those wasn't hooked up?
The power light should come on with or without the speaker wires or RCA cables from the stereo, but not all will, this is just a general rule. Double check your power hook up and see if it has power to it. Sometimes a little thing will throw the reset switch on the amp, check that also. This is assuming you have run proper power cables to the amp and have them hooked up to the proper connectors.
Q:I'm only asking this on here out of interest, this is not homework. I want to know how to calculate exact distances between to poles connected at the top by a cable. The length or height of the objects are not important to me, but if you must use an example please do so. So I want to know what formulas to use, what variables in those formulas mean, and how the slope of the cable will affect the distance. For example, if two poles have a distance between them of 0, and the cable extends 100, it would not mean that the drop of the cable (called a catenary?) would be 50, (it's misleading because you would think that since the distance between the two poles is 0, the cable would drop 50 and rise 50. But this is not taking into account the slope it has to take at the bottom of the catenary. It must lose some drop (perhaps to 48 or 49) in order to bend and rise back up...I want this out of my head, it's bugging me that I can't figure it out.
No sign can commute faster than the fee of sunshine (neglecting tachyons, that have in no way been pronounced interior the genuine international, yet in concept can in no way slow all the way down to or commute under the fee of sunshine). The ropes and poles could flex because of the fact the sign traveled alongside them. because of the fact that they'd not flow right this moment, the sign could commute at a speed nicely under c. right that's a version on the pole concept. think you have 2 very long poles crossed at an attitude. The poles are rotating from their crossed orientation to alter into extra parallel. the factor P the place the poles bypass will commute down the poles as they attitude parallel, shifting faster and faster. Can the action of P exceed the fee of sunshine? particular it could! P would not have any actual manifestation and for this reason no mass; for this reason its action isn't constrained with the aid of relativity. in spite of the undeniable fact that, if P did have mass -- as an occasion, if there became a hoop around the crossing factor -- then the poles could be compelled to flex because of the fact the relativistically increasing mass drew further and further ability from them. * To Michael under: Einstein's particular concept of Relativity states that it could consume an limitless quantity of ability to strengthen up any particle with mass to the fee of sunshine. So that is impossible to strengthen up even an electron to the fee of sunshine, regardless of the certainty that scientists can get very very close now. Photons have not have been given any mass so as that they commute on the fee of sunshine and easily on the fee of sunshine (and is the reason why every person measures an identical fee for c). Tachyons have an 'imaginary' mass (a dissimilar of the sq. root of -a million) and so as that they can't commute as slow or slower than mild... merely faster!
Q:What is the power cable accessories used to do?
Shield For uniform conductive wire and insulated electric field, 6kV and above in the high-voltage power cables generally have a conductive shield and insulation shield, part of the low-voltage cable is not set shield
Q:What is the difference between a power cable and a cross-linked cable?
You and he said that he did not understand the professional. Indoor use KGB, JDG steel pipe or PVC pipe outside the road with steel, non-road can use PE pipe
Q:ok i have somehow lost my power cable that goes from the outlet to the power block of the older version of the xbox 360 and is it possible that i can use an extension cord or something in place of that since i have lost it or do i need to get a whole new cord in all? yes this may sound stupid but i need some help on this one, thanks:)
Well I don't know of any extension chord that could replace this fairly crucial component . I think you should look for another one with a friend that maybe has a broken xbox or an old pc.. You might find the piece you're looking for on another machine like a computer or a printer . Look around and see , good luck ;)
Q:Our company needs a WELDING CABLE / DC POWER CABLE,50mm fine strand and color blue. Does anyone knows where to buy here in the Philippines? or if you know some suppliers, manufacturers please do let me know. It would help a lot. Thanks
You can buy it from okorder
Q:I have a yamaha dgx-300 keyboard, and lost the power cable to it about a year ago. Do any stores like circuit city or something carry a power cord that would be compatible with my keyboard?
Here are two adapters for your keyboard, your manual or a sticker on the keyboard, should tell you which one you need.
Q:What is the distance between the power cable and the thermal pipe when it is laid above the thermal pipe?
Cable and 10kV power line parallel laying the minimum distance of 0.5 meters.
Q:I live in the uk...
Laptops each have different power cords, because they have different connections to the laptop itself, so there's no one universal power cable. However, you can easily buy generic powercords for your specific laptop that are cheap. Just go to a site like OKorder and search for your laptop name.
Q:I'm looking to add another Light fixture on the other side of the garage, and wire it using the existing cable from the first light, I know running a normal power cable outside drywall is against code, but I've heard some people say you can use something like BX cable, or some metal encased cable outside of drywall and still be up to code? Is there a I can run this cable outside of the drywall using something like that, and if yes, what exactly would I need to use to accomplish this? I plan I running the wire from the right side of the garage door, up above the door, and to the left side of the door to install a matching light.
If exposed, you must use an armored cable or conduit. No if's, and's, or but's... Personally, I think conduit is your best option.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords