                Centrifugal Submersible Pump for Sewage Water

1.Structure of WQ Series Centrifugal Submersible Pump Description

 

WQ Series Centrifugal Submersible Pump of sewage basic dormant,along with sewage pumping,sewage things gradually deposition in the bottom of the pool. But the sediment could not force with sewage went out at the pumps normal operation of inlet water alone.So the deposit is more and more at bottom of pool,which eventually led to affect normal work of pump.Engineering clean the sewage pool regularly ,so as to avoid waste of human and material resources.We produce this kind of sewagepumps,which is mounted mixing impeller at the the bottom of pumps,along with the rotation of pump, driving the impeller highspeed mixing.Thus, stir up the deposit  of bottom, mix with water, and flow out with water.Also can match with coupler,make more quick and convenient installation and maintenance.

 

2.Main Features of the WQ Series Centrifugal Submersible Pump

• Compact structure, good appearance, low construction

Operation stably, same inlet and outlet

•Convenient installation and maintenance

•Parallel connection and have many models to be chosen for difference flow rate and head

•Horizontally and vertically installation as different pipeline system

3.WQ Series Centrifugal Submersible Pump images

Centrifugal Submersible Pump for Sewage Water

4.WQ Series Centrifugal Submersible Pump Specification

 

ModelCapacityHeadSpeedEfficiencyPowerOutlet
Q(m3/h)H (m)n(rpm)η (%)Kwmm
40WQ-12-15-1.51215290048%1.540
50WQ-10-10-0.751010290054%0.7550
50WQ-15-15-1.51515290051%1.550
50WQ-15-20-2.21520290051%2.250
50WQ-17-25-31725290053%350
50WQ-20-7-0.75207290062%0.7550
50WQ-22-20-42220290069%450
50WQ-25-10-1.52510290067%1.550
50WQ-25-32-5.52532290049%5.550
50WQ-40-15-44015290076%450
50WQ-40-30-7.54030290062%7.550
65WQ-25-15-2.22515290052%2.265
65WQ-25-28-42528290058%465
65WQ-37-13-33713290060%365
80WQ-29-9-2.2299290048%2.280
80WQ-40-7-2.2407290050%2.280
80WQ-40-15-44015290057%480
80WQ-43-13-34313290065%380
80WQ-50-10-35010290072%380
80WQ-50-25-7.55025290056%7.580
100WQ-50-22-7.55022145063%7.5100
100WQ-50-35-115035145062%11100
100WQ-65-15-5.56515145059%5.5100
100WQ-70-7-3707145075%3100
100WQ-70-22-117022145070%11100
100WQ-80-9-4809145062%4100
100WQ-80-20-7.58020145071%7.5100
100WQ-100-7-41007145075%4100
100WQ-100-15-7.510015145070%7.5100
100WQ-100-22-1510022145061%15100
100WQ-110-10-5.511010145067%5.5100
100WQ-110-15-7.511015145075%7.5100
150WQ-130-30-2213030145069%22150
150WQ-140-7-5.51407145079%5.5150

 

5.FAQ

What is your product range?

Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage

pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe

water pump, boiler water pump, etc.

Are you a manufacturer?

Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.

What information should I let you know if I want to get a quotation?

Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also

provide the pump model you are using now, price will be calculated as per the pump model, if not, we willrecommend relevant product for reference.

 

Q: What are the uses and precautions of magnetic pumps?
Installation and use of magnetic pumps:1, the magnetic pump should be installed horizontally, should not be erected, the plastic pump body can not bear the weight of the pipeline, for the special requirements of vertical installation occasions, the motor must be facing up;
Q: A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
Modify the part: (the design of regional common fire pump should be in accordance with the requirements of the original design, building design) contains a 55m high building, and the basement is about 6m, the pump reached in the basement height about 61m (common fire pump should be based on the highest floor of other low floor area, low ring and take in this case, relief measures) 61 levels, the most unfavorable hydrant to reach 0.07MPa (maximum allowable 0.5MPa) plus loss of lift at least about 90m more appropriate, of course can be higher to take relief measures (120 too high), the basic flow of lossless (with the same time there is only one building fire) according to the maximum amount of a building fire water pump set can be, there must be a backup with a preparation, and then select the appropriate pump manufacturer specification query.(the 20 houses on 99m are only shared with a 135m pump)
Q: Why should the pump be closed when the centrifugal pump is started?
Centrifugal pump has an important characteristic: when the pressure (head) is very low, the flow will be great, which can be seen from the characteristics of the pump curve. While the pump power is directly proportional to the flow rate, pump start, no pressure in the pipeline, caused by the pump flow, high power pump, and the pump motor, the rotating part from rest to high-speed operation, need a lot of acceleration, it will cause a great starting current
Q: If the suction pump does not have enough suction range, you need to add a vacuum pump to increase the suction stroke. How do you install the suction pipe of the vacuum pump? Water pump impeller is not closed, it is normal that the vacuum pump is unable to pump suction pipe to a vacuum, is it because the water pump outlet pipe connected to the role of the check valve? But the water pump, outlet pipe, check valve sealing performance can achieve the function of non leakage?
The role of the check valve:"[the water pump impeller is not closed" refers to the pump suction pump before the water without water inlet pipe and water outlet pipe gas should be connected] is a connector, a connector, still can make the level surface, in order to prevent the water flow along the pipe, until it reaches the level of the flush, then increased check valve, or pumping up water will not leak?Vacuum suction principle of self suction pump:Assuming that the pump connected with the water inlet of a sealed container, the container has plenty of water, since the start of a water pump, water is thrown out of the water impeller pump body, water inlet seal vessel due to the extraction of water to form a vacuum cavity, this assumption will be connected to vacuum cavity and exposed to atmospheric conditions of water, water at atmospheric pressure under the effect of entry into the vacuum chamber".....
Q: What is the Rhodes pump?
Best answerRoots vacuum pump (referred to as: Roots pump) refers to the pump is equipped with two opposite direction of synchronous rotation of the leaf rotor, rotor, rotor and pump housing between the walls of a small gap and no contact with a variable capacity vacuum pump.Roots vacuum pumps have been tested for long time in the fields of petroleum, chemical, plastic, pesticide, steam turbine rotor dynamic balance and aerospace simulation, so it should be popularized and applied in china. It is also widely used in petroleum, chemical, metallurgical, textile and other industries. Vacuum pump fittings are used for noise control of vacuum pumps, vacuum pump silencers.
Q: Pump unloading in hydraulic transmission,
Unloading water, from the literal interpretation is along the pump, leakage of water seal through the head, the water with certain pressure (even with relief effect seal). The water as the working quality is asked to be recycled, now the design of some use it as a water seal, and others by direct recovery, but eventually recovered.
Q: What is the relationship between the minimum suction vacuum of a pump and the required cavitation?
When the vacuum pressure is called vaporization pressure, cavitation is more than the surplus energy of vaporization pressure at the unit weight of the liquid in the pump suction port of the unit, with mark. The absorption process is to NPSH delta H: pump suction fluid allows the vacuum pump installation height is the unit of rice.
Q: What's the meaning of the pump head in the water pump, please advise, thank you
According to China Wikipedia network, the basic components of the water pump: motor, coupling, pump head (body) and chassis (horizontal).Pump is generally composed of pump body and pump head, in which the pump body refers to the spiral case, impeller, bearing, oil shell and sealing assembly, etc., the pump head refers to the impeller, bearings, oil ring and sealing rotating parts (including shaft), etc..
Q: If the calculation of the required pump flow is 45, lift 110, and the actual pump flow 100, head 125, what will happen in operation? Can I use it properly?
Centrifugal pumps are too big to measure.There is a reason why the centrifugal pump does not measure up:The pump inlet pipe blockage, leakage.The pump inlet pressure is too low.
Q: Why can't the centrifugal pump pump the vacuum?
Working principle (taking centrifugal pump as an example):Prerequisites, processes, and requirements for the overall system structure.