KZJ series slurry pump
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Product overview
KZJ series slurry pump is a single-stage single-suction cantilever centrifugal pump, is my company according to the market demand, to comprehensively consider the working characteristics of the specific application system, to absorb the advantages of similar products at home and abroad, developed a new generation of slurry pump. This series of pump adopts excellent hydraulic model design, ensure the pump is more efficient, more reliable operation, longer life, the various performance indexes exceed industry standards, in the domestic leading level.
Application field
Mine: pulp; Metallurgy: slurry, slurry
Coal ash, mortar; Building materials: including sediment pulp
Chemical industry: pulp; Water: sand, gravel, mud
Product features
1, CFD fluid analysis and design, hydraulic performance is good, for the closed impeller impeller, high efficiency, wide flow design, anti-clogging, good resistance to cavitation performance.
2, over-current components are all metal high hardness, abrasion resistant materials, excellent wear-resisting corrosion resistance
3, special rotor axial regulating mechanism, ensure the long-term stable operation of pump in the best condition
4, a variety of sealing type: vice impeller combination + packing seal and mechanical seal arbitrary choice
5, adopted the bracket, short cantilever, the large capacity fuel tank, such as reliability design, the whole machine trouble-free working time increased significantly
6, the thin oil lubrication and reasonable water cooling system, greatly extend the bearing uptime
The working conditions
Discharge aperture: DN = 40 ~ 300 mm; Traffic: Q = 30 ~ 2000 m3 / h. Head: H = 15 ~ 130 m
Medium temperature: 80 ℃ or less commonly, special can reach 110 ℃; Medium concentration: mortar concentration of 45% or less pulp density 60% or less
Mode of transmission: general for direct drive, also can be changed to the rest of the drive way according to the requirements of customers.
- Q: Fire pump and shower pump flow head selection, high resolution.
- 3, larger than 25000, the minimum water consumption of indoor fire hydrant is 20L/s4, the minimum water consumption is the flow of a fire hydrant.
- Q: How can the submersible pump level meter be connected?
- The company actively introduce international advanced production equipment and production technology, with its strong technical force, perfect equipment conditions and rich manufacturing practice, constantly development and improvement of pump products, according to the needs of users of innovative products, stable performance, excellent quality, many products export part countries and regions
- Q: 5 floor water pressure is too low, what kind of water pump is better?
- The location of the pump is too far away from the pumping pool, the suction of the pump is not enough, cavitation phenomenon, pumping water, this water pump manufacturers, the pump will be placed in a reasonable position
- Q: What is double hydraulic pump?
- [double hydraulic pump] the same drive shaft drives the rotation of two pumps, which are connected together and driven by an electric motor. The suction port of the pump is common, and the oil pressure port is separated from each other. Pump output of two shares of flow can be used alone, can also be used in parallel. This pump, a pump can play the function of two pumps. For example, there are two pumps on the loader, a pump acting as the work, a pump acting as the steering, and the double linked pump can replace the functions of the two pumps. It works by coupling the two pumps at the same time.
- Q: Is the vacuum pump air compressor?
- A vacuum pump is a device or device that uses a mechanical, physical, chemical, or physical chemical method to pump a vacuum from a container to be evacuated. Generally speaking, a vacuum pump is a device that uses various methods to improve, produce, and maintain a vacuum in a confined space.
- Q: How many pumps does the 80cm tank use?
- Filter pump to select the water per hour can be filtered more than 3 times, I personally feel that this is almost enough. Of course, the more times the better, but also consider that if the pump is too large, the water inside the tank will be too large.128X3=384LThat is, the flow must be more than 384L/H of the water pump.You can buy a bigger pump, because the pump for a long time there will be some attenuation and domestic things in general to sign data, so it should be based on your actual situation to buy. Taobao on this category is about 20~40 yuan.
- Q: What is an industrial water pump?
- The pump has the different uses, conveying different liquid medium, different flow rate, different lift range, therefore, its structure of course is not the same, the material is different, in general, can be divided into:1, urban water supply 2, sewage system 3, civil and construction systems 4, agricultural water conservancy system 5, power station system6. Chemical system 7, petroleum industry system 8, mine metallurgy system 9, light industry system 10, ship system
- Q: How accurate is the metering pump?
- Three automatic compensation valve device widely used in diaphragm metering pump, especially with suction height requirements, can only be used by three separate Fujian (safety valve, discharge valve and oil supply valve) compensation device.
- Q: What do you mean by the self coupling device on the pump?
- Auto is an installation of the pump, which comprises a pedestal, self coupling frame, a guide rod and a guide rod support, the bottom fixed coupling frame, vertical installation of two guide rods can easily be brought down without installing the pump, the pump at the bottom of the pool, the outlet of the pump and the discharge tube can automatically lock, don't need to bolt connection, automatic coupling position, so as to achieve the effect of simple and convenient. When you need to repair, pump the pump up without jumping into the sink.
- Q: What is the distance between the pump and the wall?
- What do you mean by that? If your pump is parallel to the wall! Then, the wall of the pump near the wall is usually 500mm. This is an empirical data, considering the import pipe length, pump maintenance and motor heat dissipation and other aspects of the situation to determine. Dozens of pumps installed in our company are placed in this size! Hope to be of help to you.