Specifications:

Perfect for caravans, boats, motorbikes, trucks and camping. Use it with fresh or salt water with your deck wash or to run your toilet or shower. These pumps automatically turn themselves on and off when you turn the tap on and off. Comes with filter and fittings. These pump are for intermittent use only.

A great pump for those country folk, with a small family, on tank water who only need to boost the pressure from a tank next to the house.

We have tested these pumps and found they will operate to a 2 metre suction lift and 5 metre head with no problems.

1.Maximum torque and operating efficiency/higher operating pressure and/or lower amperage than competitive pumps

2.Long life, no leaks, strong corrosion resistant

3.12/24 VDC and 115/220 VAC motors standard (consult factory for other voltages)

4.Quality components for extreme performance

5.Numerous fitting options for greater mounting flexibility

6.Voltage:12V/24V DC Diaphragm Pump,115V/230V AC Diaphragm pump

7. Expecially suitable for marine and recreation vehicle, such as boat and ship.Also suitable for Agriculture sprayer

 

Features

  • Lightweight and made from non corroding materials

  • Self priming

  • Run dry Protection

  • Easy to install

  • No maintenance

  • Simple to operate

  • Low power consumption

  • 12 months warranty

  • Automatically turns on and off

  • Comes with filter and fittings

How a Pump Works

The pump is driven by an AC or DC motor

In front of the motor is a valve assembly containing two to five valve pump chambers. Each valve chamber has a diaphragm behind it in the lower pump housing. As the motor shaft turns, an internal cam positioned behind the diaphragms causes the diaphragms to be pushed forward, then back in a continuous sequence creating a suction. As this suction builds, fluid is pulled hrough the inlet, through the various valve chamber check valves to the outlet he volume of flow is determined by several factors including: the number and size of the pump chambers,cam offset, operating pressure, fluid viscosity.


Q:Double floor sewage pump circuit diagram of a small problem
Question 4 when you need backup, you need to switch the SA switch, but where you want it. For example, when the 1# pump is running and does not reach the high water level, the 2# pump will not operate. If SA is placed in the left position, 21 and 22 are connected, and the KT is electrically delayed, and the KAB action causes the 2# pump to function. After the KAB operation, the KT will be disconnected, restored to the ready state, and also convenient for KT to restart the power on time, and also avoid the time relay to work on a long-term basis.
Q:Piston filling and peristaltic pump filling which precision is high?
If the unit area is large, the accuracy of the plunger is certainly not high. The peristaltic pump is used by means of extrusion roller extrusion pump to promote the solution, this also depends on the unit cross section size, the same motor accuracy is very important.
Q:Bolus dosage of infusion pumpWhat is the purpose of the pill dose control in the special safety standard for infusion pumps? If the risk is not properly controlled, what is the degree of risk? And how can the open infusion pump be used in this regard?
Four) release bolus dosage method can use automatic release and manual release two ways, the key is to alarm after the infusion must be stopped(five) any kind of pill dose release are not restricted to replace the pill. The total dose limit for in pipe blockage after pill agglomeration process will remove blocking accident, this time will be the rapid infusion of pill dose concentration into the patient's blood, if the total dose pill does not get test and limit, rapid infusion of this accident it may have unimaginable consequences.(six) supplies open type infusion pump overflow on the domestic market for pill characteristic parameters of consumables simply without testing and limitation. Therefore, the risk of accidental pill has become one of the residual risk of open type infusion pump supplies the most deadly.
Q:How many square cables does the submersible pump for 7.5KW need?
According to current I=13A, it is estimated that the cable is less than 10 square meters, so the cable cross section can be calculated at the ampacity of 5A per square meter. The square section of the cable is =13/5=2.6 square. According to the specifications series, optional 2.5 square aluminum cables. When the cable is longer, it is safer to choose 4 square aluminum cables.
Q:The function of centrifugal pump
4, bearings are set on the pump shaft supporting the pump shaft components, there are two kinds of rolling bearings and sliding bearings. Rolling bearings use butter as a lubricant, refueling should be appropriate, generally 2/3 ~ 3/4 of the volume is too much, will heat, too little, there is noise and fever! The plain bearings are made of transparent oil as a lubricant and fill up to the oil level. Too much oil will leak out along the pump shaft and float *, too little, the bearings will overheat and burn out, causing accidents! In the pump running process, bearing temperature is highest in 85 degrees, generally run at about 60 degrees, if higher, will find the reason (whether there is impurities, whether the oil is black, whether water) and timely processing!
Q:How many kinds of pumps are available and the operating principles of various pumps?
The volume type pump, depending on the periodic change of sealing liquid containing space volume, the energy is periodically transmitted to the liquid, the liquid pressure increased to force the liquid discharge, according to the motion form of work elements can be divided into reciprocating pump and rotary pump. Other types of pumps transmit energy in other forms. As the jet pump work on high-speed jet of fluid will be required to transport fluid suction pump after mixing for momentum exchange in order to transfer energy; water hammer pump by water when braking in the flow of energy transfer is to rise to a certain height; the electromagnetic pump is energized to make the liquid metal in the electromagnetic forces generated in the flow and transport. In addition, the pump can also be classified according to the nature of the transmission fluid, driving methods, structure, use and so on.
Q:What is the series of pumps? What is the difference between a unipolar and a multilevel? What is the meaning of each "first class"?
You're talking about a centrifugal pump. His series says the number of slices of the impeller (excluding the wheel, that is, the wheel)
Q:What do you mean by the self coupling device on the pump?
Overview of GAK self coupling device:The utility model relates to a GAK self coupling device, which is an automatic butt joint between a water outlet flange of a submersible electric pump and a water outlet pipe system.In the above additional coupling flange and the water outlet pipe seat inlet flange with a pair of wedge card, under the additional coupling flange and the water outlet pipe seat inlet flange and a pair of wedge cards in a wedge seat below the outlet pipe inlet flange card is made of elastic steel plate is fixed on the lower side of the seat pipe inlet flange. When the submersible pump water falling from above, Kaxianka additional coupling flange at the top of the wedge wedge and seat card outlet pipe above the inlet flange together, in the role of the dignity of the pump and submersible inclined wedge clamp, two flange will be put together in a pair of wedge under additional coupling flange and the water outlet pipe seat inlet flange the card will be in the elastic plate under the action of automatic card together. The utility model can solve the problem that a large amount of water leakage between the two flanges of the coupling is saved when the automatic installation and disassembly of the electric submersible pump is convenient, thereby saving energy.
Q:What are the internal losses in centrifugal pumps? How did they come about?
Hydraulic loss: the loss of water by friction, eddy, impact, etc in a flow;
Q:There are 6 pumps, two indoor fire hydrant pumps, two spray pumps, two outdoor pumps, three units, one master and one spare control cabinet. From the control room to the control cabinet, is there only 3 lines or 9 lines?... How do I get it? Where does the hydrant line come from?
You said the three line refers to the control room, the control cabinet, the main pump directly start the straight line of water pump. Each pump should be equipped with single straight line Kai, reported that the cabinet Jinglian dynamic multi line linkage control board has three buttons corresponding to a remote spray pump, fire hydrant pump, pump start outdoor fire hydrant. This requires three straight lines, from the cabinet to the three pump control cabinet, which is the 9 line you call. The water pump control cabinet is provided with a terminal for supplying a remote pump. By looking at the wiring diagram of the water pump control box, you can find the technical personnel of the control cabinet manufacturer if you can't find them.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords