• API Cast Steel Lift Check Valve 150 Class System 1
  • API Cast Steel Lift Check Valve 150 Class System 2
  • API Cast Steel Lift Check Valve 150 Class System 3
API Cast Steel Lift Check Valve 150 Class

API Cast Steel Lift Check Valve 150 Class

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
10 pc
Supply Capability:
100 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

API Cast Steel Lift Check Valve 150 Class

The features of Cast Steel Lift Check Valve

Bolted Bonnet;Swing and lift disc;Metallic seating surfaces.

Body and Bonnet Connection of Cast Steel Lift Check Valve:

The body and bonnet of Class150~Class900 check valves are usually with studs and nuts.And the body and bonnet of Class1500~Class2500 check valves are usually of pressurized seal design.

Body-To-Bonnet Joint of Cast Steel Lift Check Valve:                                                                                                         

Stainless steel + flesible graphite wounded gasket is used for Class 150 and Class 300 check valve;Stainless steel + flexible graphite wounded gasket is used for Class 600 check valve,and joint gasket is also optional for Class 600 check valve;Ring joint gasket is used for Class900 check valve;Pressurized seal design is used for Class 1500~Class 2500 check valves.

Seat of Cast Steel Lift Check Valve:

For carbon steel check valve,the seat is usually forged steel.The sealing surface of the seat is spray welded with hard alloy specified by the customer.Renewable threaded seat is used for NPS<10 check valves ,and welded on seat can be also optional if being requested by the customer.Welded on seat is used for NPS>12 crbon steel gate valves .Forstainless steel check valve,integral seat is usually adopted ,or to weld hard alloy directly integrally.Threaded or welded on seat is also optional for stainless steel check valve if being requested by the customer.

Parameter of Cast Steel Check Valve:

Standard Criteria

 ASME/ANSI/API customize 

Pressure Rating

 150 Class  300   Class  600 Class  900 Class  1500   Class  2500 Class customize 

Valve Size

 50 mm  65   mm  80 mm  100 mm  125 mm  150   mm  200 mm  250 mm 300 mm  350   mm  400 mm  450 mm  500 mm  600   mm  650 mm  700 mm 750 mm

 2 inch  2.5   inch  3 inch  4 inch  5 inch  6   inch  8 inch  10 inch  12 inch 14   inch  16 inch  18 inch  20 inch  24   inch  26 inch  28 inch  30   inch customize 

Actuator

 Automatic customize 

Connection

 Butt Welding  Flange   RF  Flange RTJ customize 

1-Body Material

 A216   WCB  A351-CF8  A351-CF8M customize 

2-Seat ring

 A351-CF8  A351-CF8M  A105+13Cr  Tool   Steel+A105 customize 

3-Disc

 Tool Steel+A216 WCB  A351-CF8M  A351-CF8  A216   WCB+13Cr customize 

4-Arm

 A351-CF8  A216   WCB  A351-CF8M customize 

5-Nut

 A194   8M  A194-8  A194 2H customize 

6-Arm pin

 A182-F6a  A182-F316  A182-F304 customize   

7-Yoke

 A351-CF8  A351-CF8M  A216   WCB customize 

8-Bonnet nut

 A194   8M  A194-8  A194 2H customize 

9-Bonnet bolt

 A193-B8  A193-B8M  A193-B7 customize   

10-Bolt

 A193-B7  A193-B8  A193-B8M customize   

11-Gasket

 graphite+304  graphite+316 customize   

12-Bonnet

 A216   WCB  A351-CF8M  A351-CF8 customize 

13-Eye bolt

 A181 customize 

Design Standard

 API 6D  BS   1868 customize 

Connection Standard

 API 605  ASME B   16.25-2007  ASME B 16.47A  ASME B 16.47B  ASME   B 16.5  MSS SP-44 customize 

Test Standard

 API 598  API   6D customize 

Face to Face

 ASME B 16.10 customize   

Pressure-temperature ratings

 ASME B   16.34-2004 customize 

Wall thickness dimension

 API 600  BS 1868

 

FAQ of Cast Steel Check Valve:

Q1:I can’t find the type of steel check valve which I need. what can I do?

The chart above only lists out some common composition of steel check valve parts.We may provide other different parts material composition according to the customer's request or the actual valve working condition.

Q2:Which certification do your products pass?

  Our products are in accordance with ISO 9001ISO 14001API 6AAPI 6DTS CEAPI607/6FA/BS6755.


Q:I'm thinking of buying a used 2006 Volkswagen Jetta. It has a 1.5 liter 20 valve engine, and I really don't know what that means. That's good, right?And is this a good used car to buy?
Are you sure its a 1.5 liter 20 valve engine? Jetta's of that year came with a 2.5 liter 5 cylinder engine (which would have 20 valves, 4 valves per cylinder.) Basically what valves do is some open to allow air to enter the cylinder, and then some open to allow the combusted mixture of air/fuel to exit. Most vehicles (to my knowledge) have four valves per cylinder nowadays, I know it was less in the past, but I think just about all have four valves per cylinder now. Five cylinders is just one more than four, one less than six. Oh, and Jetta's are actually quite nice vehicles. I would definitely pick one up if I were in the market for a used car, and found one at a decent price.
Q:I have a 97 Neon. The Canister Purge Valve circuit gives a code 31 stating that it has a problem. I've replaced the valve, which didn't make the code go away. I removed the battery for a few hours, and the code went away. I drove for about 2 weeks and the code came back on. If it's not the valve, where do I look next?
Could you describe this canister purge valve? Not sure what you are talking about here. Is it part of the emissions, part of the radiator, or what. I am just guessing it's part of the emissions. In which case, I need to know if it has a smog pump. Could be the pump, could be a clogged up cat, could be a bad EGR valve. Need some more info to help beyond this point. Good luck.
Q:I have a shut off valve under the sink that leaks when you try to turn it OFF. Why is that?I need to fix faucet leak as well. do i need to shut water off to fix faucet? Need to fix valve first. Cant figure out why valve leaks when turning off.
Because the stem washer is worn out and needs replacing, you will have to shut off the water to the whole house and you might as well replace the shutoff, probably just about as cheap and a lot more reliable fix.
Q:When i went to the cardiologist a few months ago, i remember him saying that my pulmonary and tricuspid valve were leaky, and i think he said they were a 1 on a scale of 1 to 4 which is minor and of no concern. but i have valve problems in my family and i got thining about it. anybody know what this scale is called/have more info or was it something he just made up to tell me that it was minor?
With a tape measure.
Q:I heard alot about blow off valves making your engine run rich, but I want to get a blow off valve or bypass valve when I get a wrx. (I know some people think they're gay) but i dont care how loud it is, just want that sound. so what's the difference? I've been looking at this one:
They guy above has some of it. The reason it runs rich is because when the stock by pass valve releases the air back into the intake, it does this after the MAF sensor. Since it is getting a big surge of extra air that the MAF does not read, the ECU automatically increases fuel for a split second when the BPV releases. When you suddenly release all that air into the atmosphere, the computer does not know it and still ups the fuel. That seems like not a big deal but it runs really hot and can do things like foul up plugs and even melt the catalytic converter. There is also the issue with most aftermarket units causing stalling when you first step on the gas or even when sitting still. If you want a little noise, I would first look to getting rid of the intake silencer in the fender. It looks like a milk jug. If that's not enough, then look into an open ended intake. Just be careful with intakes as they also can cause issues depending on the brand and they rear of the car. At least an intake ca be tuned for though. The issues with a BOV can be reduced a little with tuning but can not be eliminated. Sow know that you know the risks and how it does absolutely zero to benefit the car, spend the money on something better.
Q:does anyone know how much work it would take for a 1998 Mazda 626 (2.0L MFI DOHC) to change a bad intake valve?what work would be necessary and what kind of price are we talkin?
What diagnosis gave you the fact that you need a cvalve changed...dis you not replace the timing belt and it bent the valves(major head repair) or did you do a compression check to determine you have bent valve (intake valves don't burn) (lesser repair)
Q:i have a nos tank that my grandfather gave me and i was wondering if i could get a scuba valve and put it on there so i can fill my paintball tank up with the air so i dont have to go buy a scuba tank
srry but if u do that it works very poorly so i would buy that scuba tank
Q:My friend is having 3 valves in her heart replaced with pig valves. Her dr said that putting in human valves raises the risk of her body rejecting them but wouldnt your body also reject a part form different species? And if they only last a few years why use them at all? shes all freaked out about the surgery so I dont want to ask her too many questions
Pig Valve Replacement
Q:A question about a hot water radiator bleed valve. I read the advise on previous questions and bleed all my radiators except one where the bleed valve broke off when I tried to turn it with the key. My question is that on the other side of the radiator near the floor there is a black knob that turns which I assume should shut off the radiator. If my assumption is correct then I should be able to shut this off and then remove the bleeding valve and replace it without bleeding the system.. Does this sound right? Thanks,.JOE B
It has been a long time since I have seen a system like that, but I believe you are correct. The knob on the opposite side of the bleed, is a flow control, which is used to adjust the amount of heat from the radiator. If you turn this all the way off, it should stop the water flow, providing it is not corroded. However, be careful when removing the bleed as the radiator will still have water in it. Try not to drown the neighbours.
Q:I just installed three anti-siphon valves(jar top,orbit) for a sprinkler system the main water line is 3/4 then goes into my manifold (pvc)3/4 schedule 40,usually when you turn on the water it comes to a stop where you re valves begin then you either open them manually or their set up through you re timer, the problem im having when i open the main water line the water goes straight through the valves without me even opening them my question is can it be to much pressure or what can the problem be? any info helps thank you
There's a small button on top of the elec valve, which is a manual override. Find it, and be sure it's turned all the way to the right, like tightening the cap on a bottle. This closes the override but doesn't affect the solenoid operation. If this isn't the problem, disconnect the control box from power, and see if the valves now are closed. Might be wired wrong, and the solenoids are stuck open because of always being powered. Too much pressure isn't the problem -- when a home is built in a place with abnormally high water pressure, pressure reducers are installed to diminish the pressure to workable levels.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords