• 250kva/200kw cummins soundproof generator with CE approved System 1
  • 250kva/200kw cummins soundproof generator with CE approved System 2
  • 250kva/200kw cummins soundproof generator with CE approved System 3
  • 250kva/200kw cummins soundproof generator with CE approved System 4
250kva/200kw cummins soundproof generator with CE approved

250kva/200kw cummins soundproof generator with CE approved

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
300 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Item specifice

noise control for silent:
below 75db in 7metres
fuel tank capacity:
8hours or by your request
test load:
25%,50%,75%,100%,110%
delivery time:
20-25 workdays
protection class:
IP23
warranty:
1year or 1000 hours continously running
use:
land use
insulation class:
H
certificate:
CE,ISO9001

250kva/200kw cummins soundproof generator with CE approved 

250kva/200kw cummins soundproof generator with CE approved

250kva/200kw cummins soundproof generator with CE approved

250kva/200kw cummins soundproof generator with CE approved

250kva/200kw cummins soundproof generator with CE approved


   

Datasheet for 250kva&200kw cummins slient generator set 

GenSet ModelGDC250*S
Continuous Output200KW / 250KVA
Engine Brand & ModelCummins 6LTAA8.9-G2
TypeWater-cooled, 4-stroke, Natural Engine
No. of cylinder6
Bore x Stroke                                         114x145mm
Engine power                                           220kw
Compression ratio17.3: 1
Fuel consumption≤ 207g/kw. h
Displacement                                           8.9L
Engine speed                                           1500rpm


Lubricant Capacity28L


Starting systemD. C. 24V electric start
Cooling wayPositive Water Cooling Cycle
Alternator Brand & ModelGODLIKE  JDG274K(prime power 250kva)(original stamford alternator optional )
Frequency                                                     50HZ
Voltage                                                             380/220V
No. of phases3
Excitationbrushless
Insulation classH
Power factor0.8
Protection GradeIP23
Noise control ≤75db in 7 metres 
Voltage Regulation, Steady State≤ ± 1%
Control Panel - Standard equipped or LCD digital control module(DSE&SMARTGEN)
8hours Base Fuel Tank & battery included
Options: ATS

   GODLIKE POWER Diesel Generator Set Advantage:
·  50Hz@1500rpm or 60Hz@1800rpm all are available
· AVR delivers non fluctuating power
· Panel type digital control panel/manual control 
· 12 Volt / 24 Volt electric starter ensures easy starting
· Low oil pressure shut down system
· Low fuel cut out protection
· Low water cut out engine protection
.High water temperature cut out engine protection 
· Enclosed structure ensures quieter operation
· Alternator (Dynamo) excitation mode brushless self excitation
· Three-phase output meets differing requirements
· Four Cylinder, four stroke, water cooled diesel engine
· 8 hours running @ full load on a single tank of fuel
· Dual access doors for easy maintenance
· Optional automatic or manual transfer switches available
· ATS ( auto transfer switch for city power and generator power ) / AMF (auto mains failure) /parallel running for option
· Weatherproof and soundproof, enclosure high grade steel protected by powder coat painting and incorporate internally mounted exhaust silencers
· Noise Level (65-75dBA @ 7m)
· All ratings are at sea level

After-sales Service:
1 year or 1000 continuously running hours subject to the earlier one. 


Our Diesel Generator Set Production Range is as follows:

* Engine (motor) for Choice 

1. Cummins  :23kVA - 1500kVA
2. Perkins    :9kVA - 2250kVA
3. Lovol (China): 30kVA - 138kVA
6. Yangdong (China) :11kVA - 63kVA
7. Weichai (China) 30kVA - 188kVA
8. XiChai (China) :18kva-375kva
9.Yanmar(Japan):6kva-58kva


* Canopy for Choice 
1. Silent type (75- 80 dB(A) at 7 meters)
2. Super Silent type (65-70 dB(A) at 7 meters )
3. Open type 
4. Trailer type (mobile) 
5. Container Type 
6. Parallel System 
   Optional Accessories 

1. ATS(Automatic Transfer Switch);

Which can start the diesel generator when the main power is off; when the main power comes back, it will shut down generator.

 

2. MCCB (Molded case circuit breaker);

It can protect the loading machine and the diesel generator.

 

3. Battery charger(float charger);

When the generator hasn't been used for long time, the batteries will be no power, in that way, you can't start the generator. But the battery charger can charge the batteries from main power.

 

4. Extra daily fuel tank;

It will be requested while the base fuel tank capacity is not enough for daily fuel consumption.

 

5. Paralleling system;

This system can make several generators work together and automatically distrubute the load according to set.

 

6. Remote Control Panel:

Which can control the generator by computer, if use a RS484 or RS232 digital cable to connect the generator to the computer

 

7. Water Separate(additional cooling system);

If the ambient temperature is too high, it will be harmful to the diesel generator. Fan and water cooling is not enough for radiate. The water separate system is much better for cooling, and the life of generator will be much longer.



Q:I am setting up a bio gas plant on my farm in india. I want to know if generators are available for bio gas. What are the modifications required to petrol and diesel engines to make them run on bio gas.
bio gas plant is from the place u get gases like methen,that's far less carbon and burns like proppane gas(cooking gas) you may equipped bio gas plant easly,presented u would desire to ve uncooked textile,like cow dung orfood waste like issues,
Q:Can anyone help me figure out where I can find a diesel motor that can be used in a motorcycle? Can I take the motor out of a diesel generator or should I buy a new/used one made specifically for a motorcycle?
diesel motors are not exactly meant for huge changes in load and very high revs typical of a motorcycle a diesel generator? those run in a very very narrow powerband go for the one made for a motorcycle if their are any unless you have a really good reason just get a 4 stroke
Q:also is it probability that will damage my computer or UPS
ups will steady current, wont damage pc
Q:hiam in the process of purchasing a flat.under the electrical specifications, the builder has specifid the following. please explain me what does it mean by3 phase power supply with automatic change over switch and what does it mean by RMU Transformer with Advanced Features
This electrical specification describes some aspects of the electrical distribution system for a block of flats (apartment building in USA terms). A 3 phase power supply is 3 live wires and a neutral with 400 volts or so between any two live wires and 230 volts or so between any live wire and the neutral. Each flat would be connected to one live wire and neutral. A change over switch is a switch that can switch the load from one power source to another. It could switch between two mains connections from the power company or it could switch between the power company mains and a standby diesel generator set. An RMU transformer is a ring main unit transformer. The transformer would be the step down or substation transformer from the transmission line voltage to the 400 volt level. There would probably be one transformer for all of the flats, possibly two if there are two mains connections from the power company. The RMU designation indicates that the transformer includes additional components such as the change over switch and main circuit breaker as a single piece of equipment. Advanced features might include such things as transformer temperature monitoring, load monitoring, and remote indication provisions. Unless the features are enumerated, it isn't a particularly useful description. It may or may not include features in addition to the minimum required by government regulations. If you are purchasing only an individual flat, this might offer some assurance that the electrical system is modern and reliable, but it is a very poor description to offer prospective purchasers of individual flats.
Q:I need a silent diesel generator of power capacity of 25 kW, i am going for the following brands(suggest something)1. Jackson Cummins2. Mahindra powerol3. Kirloskar
i have seen Kirloskar unit in an office complex. Seems to be good. No idea about the other two brands.
Q:can caterpillar diesel generator generate power for 1 month without any shutdowns? which is generator good GAS or Diesel?
It will depends upon the maintencence / operation / safty precautions taken by tghe user. i think the diesel gen is batter than the gas genreratoe.
Q:i have a 7.5 onam diesel generator that runs for 15 min and shuts down i get a code 33 (overheating)I change coolant,cap and thermostat also checked air flow Still no luck.any ideas anyone
This may sound stupid, but check the belt. Make sure it's actually on there. The Onan QD's sometimes throw a belt. I have seen them break too. Make sure that's on. You may have an internal water pump issue as well - impeller fell off, etc (rare but possible). Another issue could be a blocked radiator. If your radiator is blocked with sludge, you may not even know. I usually check various spots on the block, thermostat housing and radiator while running with a infrared temperature probe to see if it's actually getting hot BUT BE CAREFUL doing that because there's a risk of damaging your unit. That's actually a last resort thing. It may just be a bad high temp switch. But make sure everything else is right first. Full radiator, belt, t-stat (you already did). Oh, I just thought - make sure you have the right temp t-stat in there. The one I have in the shop (1997 7.5 Kw HDKAJ Spec D) takes a 71 Degree C (160 degree F) one. Anything higher will set off the high temp system I believe.
Q:I have a diesel truck as well as a 25,000 watt diesel standby generator for my home. I'm curious if they will be affected should a solar flare zap us. I'm not too well versed in the whole solar storm issue.
No. Diesel equipment is totally mechanical - no electronics to be affected.
Q:I want to power a water heater, a blower fan, and a small water pump continuously with a diesel generator run on Biodiesel. Is it possible to set up a system of some deep cycle batteries that will carry the load for say 1/2 hour or 1 hour and have the generator kick on automatically when the voltage drops to charge the batteriesthis way the generator will not be run continuously. What would you need to set this up? Anything besides what I have mentioned?Josh
What is the amp draw of the appliances how big are the batters and what is the output of the generator? too many variables for a good answer
Q:What is the most important parameter of diesel generator?
rated voltage (Ue): refers to the diesel generator set in the normal operation of the line voltage, the unit is V (V) or kV (kV)

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords