Standard Hot Dipped Galvanized Wire For Gabions

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Commercial Galvanized Steel Wire

(1) Quality : Meet GB/T 343 standard and other requirements of relevant standards .

(2) Zinc Coating: Meet GB/T 15393 standard and other requirements of relevant standards .

(3) Raw Material : Wire rod ——1006 , 1008 , 1018 , Q195 , etc, and zinc with 99.995% purity.

(4) Tensile Strength Range

Size (mm)

Tensile Strength (mpa)

0.15-1.60

290-550

0.65-1.60

400-550

1.61-6.00

400-1200

(5) Application : Used in wire mesh , artware , metal hose , binding for agriculture and construction , etc.

(6) Packing

Size (mm)

Coil Size

Spool Packing

Big Coil Packing

ID (mm)

OD (mm)

0.15-0.26

6 inch

1-14kg/spool

0.27-0.60

8 inch

1-100kg/spool

0.61-1.60

12/14/16 inch

1-100kg/spool

250-400

400-770

1.61-6.00

14-500kg/spool

450

800

508

840


(7) Zinc Coating

Meet GB/T 15393 standard.

Size (mm)

Weight of Zinc-Coating ( g/m2 )

A

AB

B

C

D

E

F

A1

B2

0.25

30

20

18

>0.25-0.40

30

25

20

>0.40-0.50

30

20

>0.50-0.60

35

20

>0.60-0.80

120

110

40

20

>0.80-1.00

150

130

45

25

>1.00-1.20

180

150

50

25

>1.20-1.40

200

160

50

25

>1.40-1.60

220

180

50

35

30

>1.60-1.80

220

180

70

40

30

>1.80-2.20

230

200

80

50

40

>2.20-2.50

240

210

80

55

40

>2.50-3.00

250

230

90

70

45

>3.00-4.00

270

250

100

85

60

30

>4.00-5.20

290

270

110

95

70

40

>5.20-6.00

290

270

245

110

100

80

50


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:wiring diagram for an rccb?
RCCB is Resual Current Circuit breaker, so it operates sensing the difference in voltage in the phases and neutral... ie if an earth leakage is occured there will be a difference in the current flowing through and hence activating the trip ckt if the RCCB and causing trip. Thus the earth connection is not required for the rccb.. so go ahead without the earth wire...
Q:Wiring Stereo In VW Polo 98?
When you wired it did you butcher the wires or use a wiring harness? With the wiring harness, everything is labeled and color coded. Match colors to the kenwood wiring harness, splice or use butt connectors, plug harness into factory harness and player, attach antenna wire and you're done! If you did butcher the wires and left enough wire, repair the harness and buy a harness kit at your local sound shop, really cheap too! Good luck!
Q:domestic wiring?
One set of wires will be the mains feed the 2nd set will be the mains feed to the next light in the circuit and the 3rd set will be the switch wire. Copy like for like when changing them, taking care not to lose sight of the switch wire...
Q:Mass hung by two wires?
To solve this, you have to find 2 equations, because there are 2 unknowns. Assume, Tension in wire 1 = T1 Vertical component of T1 = T1 sin42.2 Horizontal component of T1 = T1 cos42.2 Tension in wire 2 = T2 Vertical component of T2 = T2 sin58.8 Horizontal component of T2 = T2 cos58.8 Since the sign board is in equilibrium, the forces must balance each other. Horizontally, the horizontal components of both forces are balancing each other. Therefore, T2 cos58.8 = T1 cos42.2 T2 = (T1 cos42.2) / (cos58.8) -------------------(1) For the vertical components of the wire, both are balancing the weight of the sign. T1 sin42.2 + T2 sin58.8 = (41.7)(9.8) T1 sin42.2 + T2 sin58.8 = 408.66N ----------------(2) Combine (1) into (2), T1 sin42.2 + (T1 cos42.2)(sin58.8) / (cos58.8) = 408.66 T1 ( sin 42.2 + cos 42.2 tan 58.8) = 408.66 T1 = 215.66N Subst T1 = 215.66N into (1), T2 = (T1 cos42.2) / (cos58.8) = 308.4N Hope it is correct ^^
Q:wiring diagram for hunter ceiling fan?
Hunter Fan Wiring Diagram
Q:Double pole breaker with one hot wire?
No you need two hot and a neutral your element needs 240 volts.
Q:220 wiring?
if the dryer rateing plate says 220 volt 30 amp you can use # 10 stranded wire/ romex 2 colored wires and 1 ground (bare) or insulated green wire.
Q:2004 dodge durango radio wiring diagram?
check out the link this is where i always go and always im able to find the car listing im looking for goodluck!
Q:can i make magnet wire at home?
You can often get varnished wire at an outlet such as radio shack. I have also used the yokes of old TV sets that I usually got for free at a local repair shop. I had to carefully unwind the coils. The wire in an automobile ignition coil is another potentially free source. You can purchase electrical insulating varnish as well. Krylon makes an aerosol variety and most others come in a regular can, but you would have to be creative in dipping the wire and suspending it to dry without damaging the coating.
Q:what type of wire can u use for amp?
Home okorder.com/... (spanky, well trying to run solid wire in a car would be a real task! lol) And, 4 gauge can handle more than 95 amps.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range