Hot Dipped Galvanized Steel Wire For Gabions

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Commercial Galvanised Steel Wire

(1) Quality : Meet GB/T 343 standard and other requirements of relevant standards .

(2) Zinc Coating: Meet GB/T 15393 standard and other requirements of relevant standards .

(3) Raw Material : Wire rod ——1006 , 1008 , 1018 , Q195 , etc, and zinc with 99.995% purity.

(4) Tensile Strength Range

Size (mm)

Tensile Strength (mpa)

0.15-1.60

290-550

0.65-1.60

400-550

1.61-6.00

400-1200

(5) Application : Used in wire mesh , artware , metal hose , binding for agriculture and construction , etc.

(6) Packing

Size (mm)

Coil Size

Spool Packing

Big Coil Packing

ID (mm)

OD (mm)

0.15-0.26

6 inch

1-14kg/spool

0.27-0.60

8 inch

1-100kg/spool

0.61-1.60

12/14/16 inch

1-100kg/spool

250-400

400-770

1.61-6.00

14-500kg/spool

450

800

508

840


(7) Zinc Coating

Meet GB/T 15393 standard.

Size (mm)

Weight of Zinc-Coating ( g/m2 )

A

AB

B

C

D

E

F

A1

B2

0.25

30

20

18

>0.25-0.40

30

25

20

>0.40-0.50

30

20

>0.50-0.60

35

20

>0.60-0.80

120

110

40

20

>0.80-1.00

150

130

45

25

>1.00-1.20

180

150

50

25

>1.20-1.40

200

160

50

25

>1.40-1.60

220

180

50

35

30

>1.60-1.80

220

180

70

40

30

>1.80-2.20

230

200

80

50

40

>2.20-2.50

240

210

80

55

40

>2.50-3.00

250

230

90

70

45

>3.00-4.00

270

250

100

85

60

30

>4.00-5.20

290

270

110

95

70

40

>5.20-6.00

290

270

245

110

100

80

50


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:16 gauge speaker wire with 4 gauge power wire?
Actually YES, the speaker wire should always be twelve gauge especially if you want crystal-clear sound. And you SHOULD get 4 gauge power and ground wires as well. They sell great quality audio cables at Walmart.
Q:guitar wiring help..PLZ!?
The bare wire is usually ground. Solder that to the ground wire that you should have wired to the bridge, and also to the sleeve connection on the output jack. The insulated wire carries the signal. Depending on the configuration you are running, whether it be a single pickup, two pickups, and global controls or dedicated controls, this can go in different places. Let's say, hypothetically, that you are using a single pickup. Then, the signal wire would go straight to the Volume pot. The tone pot would be an offshoot of the volume, which tapers the high end. There are multiple ways to wire a tone pot, should you install one, and the wiper of the volume pot goes to the tip connection of the output jack. For more information, look at some pickup wiring guides. Seymour Duncan has a lot of good ones, if you go on their site and search.
Q:How do I wire a 3 wire fan/light switch?
Even though you gave an excellent explanation of the problem it is still too difficult to give you a proper answer without seeing the situation. If you have the money it is best for you to hire a pro. If not, then do you have a friend who knows a lot about wiring. The short you speak of is troubling and could be dangerous. You need to fix the problem soon. So get a pro or a qualified friend.
Q:I am installing a GFCI and the box has a red wire...what is it for?
It sounds like that receptacle was half switched. Receptacles are designed to have the small brass tab on the black side snap off and one half is constantly alive (black wire)and the other side is connected to a wall switch (red wire). Is this in a room with no ceiling light? Switched outlets are usually for a lamp to turn on as you enter the room. GFCI outlets are not designed to be switched on and off as both sides will go off. Is this room in a basement, kitchen, bathroom or near water pipes? You may not be required to have it GFCI protected. If you can and want a GFCI then try another outlet near by.
Q:Subwoofer wiring error?
you okorder.com/... you can pull 20 amps 6.6 feet but you can not pull 25 amps any distance so if your amplifier has two 15 amp fuses in it, you will need to swap out the 12ga section for 8ga.
Q:What are the differences between wired and wireless microphones?
The instant one does no longer have the mute function together as the under pressure out one does. The instant one you ought to cost whilst it dies and the cable isn't long adequate to attain your ear together as its plugged into the console.
Q:Wiring thermostat - new one has less wires?
The black wire should be for ground. You and try to connect it without the black first to see if everything works ok, if it does tape off the black and tape it to the other wires. If not look at your UPM diagram and see which port is for ground and it should hook up with that wire. But I would double check with the heat pump wiring diagram to see what that black goes to and verify that wire with a multimeter.
Q:Can we get rid of wires?
Losses are too high!
Q:3 black wires, 3 white wires, one red wire light fixture?
the white wire is neutral and hooks to the white on the light the black wire you had hooked when the light stayed on is the feed wireit hooks to either the other the other red or one of the black wires depending on how the switchjes are wired. i would try hooking the feed black to the red and the other 2 black to the black light
Q:Does burnt wire still let electricity flow?
It would help to know exactly what you're trying to do here. Like Gary said, I'm not sure what you mean by inside those wires they have insulation. I'm trying to guess what you're trying to do here and you say you need to connect some wires. Are you trying to connect two sets of insulated wires together? If so, I'm guessing that you needed to strip the insulation off of the ends of the wires to expose the conductors and connect together? If that's the case, usually we use a wire stripper or a small razor blade to cut the insulator around the wire and then pull off the sheath, leaving clean wire underneath. Burning the insulation off is not going to make copper wire not work (if you oxidized the copper, you'd have to heat it way hotter than a typical flame, and it would not be metal any more--it would be crispy). So if you still have flexible metal left over after burning off the insulation, then you still have a conductor. The problem, and the reason why we don't usually burn off insulation is that you're going to end up with a bunch of burnt up goo and oxides on the surface of your wire which will make it not connect well with another wire surface to surface. You can probably solve this problem by lightly sanding or scratching the burnt parts of the wires. Or just cut off the burnt part and try stripping it with a blade instead. Then make sure to insulate your connection with electrical tape or something so that you don't have bare wires that can touch each other and short out. If you're trying to do something different, please explain more. In general, though, you're not going to ruin copper by burning it, but you will tend to coat the outside of the wire with stuff that doesn't insulate well. You want shiny copper when you are connecting two pieces together.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range