• QJ Multistag Submersible Centrifugal Water Pump System 1
  • QJ Multistag Submersible Centrifugal Water Pump System 2
  • QJ Multistag Submersible Centrifugal Water Pump System 3
QJ Multistag Submersible Centrifugal Water Pump

QJ Multistag Submersible Centrifugal Water Pump

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
1000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1. Product overview :

 QJ series deep well submersible waterpumps are widely used in farm irrigation, sprinkler irrigation, getting water from well, water supply and drainage system for industrial and civil building, water diversion project in hilly and mountain areas water drainage project in at low-lying areas, water supply and drainage in urban and rural's mining enterprisesand various ther kinds of water conservancy facilities. Its features are that the Motor and pump are assembled into a whole, so that it is simple in structure, convenient to assemble and disassemble, easy to use and maintain safe to operate. Otherwise, it covers an small area and does not pollute water.

 

2. Operation parameters :

(1). Flow range : 10-500 m3/h

(2). Lift range : 10-600m

(3). Applicable well diameter : φ175-φ400mm

(4). Diameter scope:φ32—φ203mm;

(5).Temperature range: -15—100°C.

 

3. QJ using condition:

(1) 380V voltage deviation is no more than ±5%,frequency is 50HZ, three-phase power deviation is no more than ±1%.

(2) Motor cavity must be filled with water.

(3) The first stage impeller of the pump should be more than 2mm below the moving water surface,  pump unit should be less than 70m below the static water level.

(4) The distance from the motor bottom to well bottom must be more than 3m.

(5) Water temperature should be no more than 20°C.

(6) Sand content of the water ( by mass) should be no more than 0.01%.

(7) PH value of water 6.5-8.5.

(8) Hydrogen sulfide content of the water should be no more than 1.5mg/L.

(9). Chloride ion content of the water should be no more than 400mg/L.

(10). Water yield of water source should ensure the requirements of pump continuous working.

 

4. Material

Impeller: Cast iron HT200,or stainless steel

Pump bowl: Cast iron HT200,or stainless steel,such as ss304 ss3016

Pump shaft : Cold-drawn steel with chrome plating,or stainless steel SS304 SS316

Motor Seal: Rubber O-ring seal,mechanical seal

Motor regulating sleeve: Rubber

 

5. FAQ

(1).  Can I get trained on CNBM products?

Yes, we provide training courses in our factory (products, general and specific pump technology, hydraulics, and practical applications). Please consult your sales manager or get in touch with our headquarters for more information.

(2).  Are your pumps cheaper than those of your competitors?

CNBM aims to give its customers the highest standards of quality and service and delivery times, all at a reasonable price.

(3).  How long is your warranty?

Unless otherwise expressly authorized in writing, by specifying a longer period or different conditions, CNBM states that, for a period of twelve (12) months from delivery date, all Products supplied are free from defects in materials and workmanship, and conform to the applicable specifications. Either the delivery documentation or the invoice must be provided to prove delivery date. In absence of such documents, the production date appearing on the product label may suffice.

(4) Are your pumps cheaper than those of your competitors?

CNBM aims to give its customers the highest standards of quality and service and delivery times, all at a reasonable price.

(5) Do you have self-priming pumps?

Yes, our product portfolio also includes two ranges of self-priming pumps: self-priming electric pumps and self-priming side channel pumps.

(6) Is it really necessary to fit a bleed valve for the boxes?

It is always best to have a bleed valve as the gas produced by the fermenting sewage is potentially hazardous.



QJ Multistag Submersible Centrifugal Water Pump

QJ Multistag Submersible Centrifugal Water Pump


Q: What is a water pump coupling device?
Advantages of water pump coupling device:1. automatic coupling device, easy installation and maintenance. In the absence of automatic coupling device, fixed installation, such as water pump failure, maintenance personnel need to unscrew screws, lifting pumps for maintenance, or with other small pumps pumping water perfect maintenance,If the water is dirty, it is difficult for people to get down, when the inspection and repair encountered great difficulties. But it is equipped with GAK submersible sewage pumpAfter the automatic coupling device needs lifting, the person can directly lift the water pump without the need to screw the screw into the waterAfter graduation, down the guide rail, you can realize the sealing of water pump and pipeline, so as to make the pump run normally. Small sewage pumps are freeInstallation, large sewage pumps are generally equipped with automatic coupling device, automatic installation, installation and maintenance is very convenient.
Q: What are the uses and precautions of magnetic pumps?
Installation and use of magnetic pumps:1, the magnetic pump should be installed horizontally, should not be erected, the plastic pump body can not bear the weight of the pipeline, for the special requirements of vertical installation occasions, the motor must be facing up;
Q: A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
Such as a large pressure of about 10m or about 0.1MPa} because the most unfavorable point fire hydrant requires more than 0.07MPa (7m) and 0.5MPa (50m) is not greater than the pressure, so unless the pump is located in the 50m Valley is still lower than the garage, or add to the valve (or the use of fire hydrant decompression) otherwise, it is 120m lift pump
Q: Troubleshooting of diaphragm pump
In the application of the pump, these conditions are likely to encounter. Each situation can be divided into several possible reasons. This guide lists the causes of failures and gives appropriate corrective maintenance measures. The meaning of all the specific terms in the guide is listed later.Air valves - copper or stainless steel valves are bolted to the center of the pump by four bolts.The piston aluminum cylinder is enclosed in the air valve to control the gas flow.Cavitation - because the pump inlet for the amount of fluid to reduce or lack, the pump discharge is less than the amount of quantitative. In fact, the fluid chamber is full of fluid before it is discharged.Static pressure drop - the inlet pressure from the pump centerline to the free point - the inlet is measured in pounds, including the specific gravity and velocity of the fluid.
Q: Is the vacuum pump air compressor?
No, both work in the opposite way. Air compressor, referred to as an air compressor, is a machine that produces compressed air (positive pressure). The vacuum pump is just the opposite.
Q: What is the function of a submersible pump?Do you have any knowledge about submersible pumps?.
Important equipment for deep well water extraction. When in use, the whole unit dives into the water. The extraction of groundwater to the surface is water, mine rescue, industrial cooling, irrigation, water lifting, ship ballast, also can be used in fountain landscape, hot water submersible pump for hot spring bath, but also can be applied to the extraction of groundwater from wells, can also be used in rivers, reservoirs, canals and other water projects. The utility model is mainly used for farmland irrigation and water for human and livestock in mountain areas, and can also be used for central air conditioning cooling, heat pump units, cold pump units, cities, factories, railways, mines and site drainage. General flow can reach (10m3~650m3) per hour, head up to 1500 meters.
Q: What are the problems that should be paid attention to when using vacuum pumps?
(14) vacuum pump used in the winter season, after stopping the pump body, lower drain plug unscrew medium on the net. To prevent cracking.(15) the vacuum pump has been disabled for a long time. All the pumps should be taken apart and dried. The rotating parts and the joint should be coated with grease and properly preserved.
Q: Do you have a suction pump higher than 9 meters?
Pump rated suction generally 7 meters or so, it is estimated that no one calibration pump suction stroke 9 meters. Calibration suction range of 9 meters is not reliable.
Q: No negative pressure water supply equipment, both the main pump and auxiliary pump, power is not the same, how to choose the control cabinet?
1) microcomputer frequency conversion control cabinet2) water pump unit3) current stabilizing compensator4) vacuum suppressor5) all kinds of pipe fittings, valves and so on
Q: What are the characteristics of the piston pump?
1 、 built in overvoltage protection and flow correction system.6 、 large screen LCD display.7. The well designed exhaust device can effectively remove the bubbles in the liquid.8, flow and pressure settings can be memory, and PLC communication (custom).

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords