Cummins Diesel Generator 500KW/625KVA C35

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
300 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

ENGINE DATA
Manufacturer:Chongqing Cummins Engine
Model:Original Cummins KTAA19-G6A, 4-cycle
Air Intake System:Turbo, Water / Air Cooling
Fuel System:Fuel Pump, EFC
Cylinder Arrangement:6 in line
Displacement:18.9L 
Bore and Stroke:159X159(mm)
Compression Ratio:13:1
Max. Standby Power at Rated RPM:610KW/830HP 
Governor Type:Electronic
Exhaust System
Exhaust Gas Flow:2054L/s
Exhaust Temperature:584
Max Back Pressure:10kPa 
Air Intake System
Max Intake Restriction:6.23kPa 
Burning Capacity:750L/s
Fuel System
100%(Prime Power) Load Consumption:206 g/Kw.h
75%(Prime Power) Load Consumption:205 g/Kw.h
50%(Prime Power) Load Consumption:206 g/Kw.h
Oil System
Total Oil Capacity:50L 
Oil Pressure at Rated RPM:345-483kPa
Cooling System
Total Coolant Capacity:116.5L 
Thermostat:82-93
Max Water Temperature:104℃
ALTERNATOR DATA
Manufacturer:Original STAMFORD ,Marathon,MECC,Kaijieli
Frequency and Speed:50Hz/1500rpm
Altitude:1000m
Connecting Type:3 Phase and 4 Wires, “Y” Type Connecting
Power Factor:0.8
Protection Grade:IP23
Exciter Type:Brushless, Self-Exciting, with AVR
Insulation Class, Temperature Rise:H/H
GENERATING SET DATA
Voltage Regulation, Stead State:±1%
Volts Warp(Sudden Reduce):+25%
Volts Warp(Sudden Increase):-20%
Frequency Regulation, Stead State:5% 
Frequency Warp(Sudden Reduce):+12%
Frequency Warp(Sudden Increase):-10%
Frequency Recovery Time:5S
Open Type Size:3700(mm)X1570(mm)X2080(mm)
Open Type Weight:4820kg
Control System:Original Uk deep sea auto controller 
Standards: ISO9001, ISO14001, European CE


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Under what conditions would an industrial Turbo generator need to trip. ?
I'm assuming by trip you mean shut down/off Plenty of reasons: 1) overheat, most common cause, could be lost water pump or water supply or cooling lines plugged 2) electrical, although diesel does not use sparkplugs there are electrical components. There are glow plugs that get the whole process started when cold, there is a starter motor that gets it all going and there is some method to keep the fuel warm enough to flow correctly 3) Starve for fuel, either fuel ran out, to low temp so its sludge 4) Loss of oil pressure that is used for lubrication 5) Ouput limits, there will be an overcurrent/overvoltage system regulating the output of he generator and if it gets really out of wack then it will kill the whole thing to prevent damage to everything That's all I can think of right now
Q:Diesel generator sets which good?
When choosing a diesel generator manufacturers should also pay attention to: diesel generator is composed of a diesel engine and a generator,
Q:what is the relation between horsepower of a diesel engine and its fuel consumption?
Go to some diesel engine websites. They should have the fuel consumption in terms of brake horsepower hours.
Q:What are the pros and cons of diesel,gasoline,ac and dc generator?
A battery powered wheel chair has everything you need. You can buy an old one cheap and fix it up to work as your automated vehicle. Use Lithium Ion batteries for maximum power or one of the new AGM car batteries that provide deep discharge operation.
Q:Does a nuclear power plant get it electricity from its own reactor or an outside source?
The power required to run house loads does come from the generator. If the generator trips off line because of a protective action or because the reactor itself has shut down, then the energy comes from the grid. If the grid has failed (perhaps causing the generator to trip) then power is still possible from a second offsite source. If both offsite sources fail for some reason, then the emergency diesel generators can power the required minimal loads required to cool the decay heat from the reactor.
Q:Gas stations during Sandy STorm. Why not use gas powered water pump to pump gas out of refil station tanks?
horse and buggy. no fuel needed.
Q:KIPOR DIESEL GENERATOR KDE 6700TA 5KVA?
needs new brushes on commentator or commentator is dirty,
Q:Why isn't oil used for electricity?
probably because of the price, not much more i can think of
Q:Does anyone sell a full set of Yamaha Portable Generator Shop service manuals on CD?
try okorder
Q:How many hours can I expect this generator to last?
ok so you a caring owner of the kubota gen. well a bit of smoke is ok w/ 1k hrs and you dont say how many times you use it ie you start it up just to ck it or your actualiy putting a load on it with power being draw on the gen. ? also its important that the oil your using is combatible with the weather and area your using it in trust this 40 w in the rockies aint gonna work and in winter you need a heater in the sump too keep oil warm

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates