• Diesel Generator Volvo 200kw/250kva System 1
  • Diesel Generator Volvo 200kw/250kva System 2
  • Diesel Generator Volvo 200kw/250kva System 3
Diesel Generator Volvo 200kw/250kva

Diesel Generator Volvo 200kw/250kva

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
100 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Product Description

A diesel generator is the combination of a diesel engine with an electric generator (often an alternator) to generate electrical energy. This is a specific case of engine-generator. A diesel compression-ignition engine often is designed to run on fuel oil, but some types are adapted for other liquid fuels or natural gas.

Diesel generating sets are used in places without connection to a power grid, or as emergency power-supply if the grid fails, as well as for more complex applications such as peak-lopping, grid support and export to the power grid.

 

Main Product Features:

General Features: EngineVOLVO TAD734GE   

Radiator 55`C max, fans are driven by belt, with safety guard 

24V charge alternator

Alternator: single bearing alternator IP23, insulation class H/H 

Absorber

Dry type air filter, double fuel filter, oil filter, pre-filter

Main line circuit breaker

Standard control panel

Oil drain pump

Two12V batteries, rack and cable 

Ripple flex exhaust pipe, exhaust siphon, flange, muffler 

User manual

 

Product Specifications:

1. Manufacturer / Model: VOLVO TAD734GE, 4-cycle

2. Air Intake System: Turbo, Air/Air Cooling

3. Fuel System: Elec. Injection, Common Rail    

4. Cylinder Arrangement: 6 in line

5. Displacement: 7.15L

6. Bore and Stroke: 108*130mm

7. Compression Ratio: 17

8. Rated RPM: 1500rpm

9. Max. Standby Power at Rated RPM: 238KW/324HP (with fan)

10. Governor Type: EMS2

 

FAQ:

Q1: What is Prime Power and Standby Power Rating?

A1: Prime Power (PRP): Prime power is available for an unlimited number of annual hours in variable load application, in accordance with GB/T2820-97eqv ISO8528; A 10% overload capability is available for a period of 1 hour within a 12-hour period of operation. Standby Power Rating (ESP): The standby power rating is applicable for supplying emergency power for the duration of a utility power interruption. No overload, utility parallel or negotiated outage operation capability is available at this rating

 

Q2: How do we guarantee the quality of our products?

A2: We have established an advanced quality management system which conducts strict quality tests at every step, from raw materials to the final product. 

 

Q3: How soon can we receive the product after purchase?

A3: Within three days of placing an order, we will begin production. The specific shipping date is dependent upon international and government factors, but is typically 30 to 40 workdays.

 

Q4: What is your after sales service?

A4: CNBM provides a full line of brand new and high quality products. Each and every unit is strictly factory tested. Warranty is according to our standard conditions: a, 15 months, counted on the day CNBM sold to the first buyer; b, One year after installation; c, 1000 running hours (accumulated); subject to the earlier one. Service and parts are available from CNBM or distributors in your location.  

 

Diesel Generator Volvo 200kw/250kva


Q: For what reasons are you in favor of using nuclear energy to generate electricity? For what reasons are you against nuclear power? consider the nuclear plant explosion in Japan.
Vladimer K nailed it. coal is an environmental disaster. wind farms are pretty, at least to me. the wind doesn,t always blow. the media storm surrounding the japanese nuc plants is helping news services make money. how much do you hear about the real disaster in japan? you know, the one that killed tens of thousands of people? i.,ll take nuc above other power sources any day.
Q: Does a current carrying conductor experiences a force onlywhen the current is in the same direction as the magnetic field?
Current carrying conductor will always experience force, weather the magnetic field is from external or self induced magnetic field. The reason I know this is because I have been involved in testing 50,000 watt diesel generator sets by applying a dead short (1000's amps) across the output. And have observed double (00) cables jumping on the laboratory floor (like a garden hose when you slam the valve shut).
Q: Hi, I'm fifteen and going to Tanzania in February on a Mission trip. I don't know what to wear, because I don't wanna wear Nike Shorts and offend people. I'm on a mission trip so I definitley wanna be representing Christ. I also need a pack list so I wont be forgetting anything. Also, what do I take money-wise? Cash, debit nfused. First time over seas. HELP! God Bless! Merry Christmas!:) -Emma
Hello okorder
Q: Effects on health, economy, business, the environment, etc.
Deisel emissions are evil
Q: I want to place a quiete genarator which is about 7kva. Will it disturb people in my apartment? We usually make a lot noise in the building. But doesn't sound a lot also?
a 7kva generator isnt even that quiet. i know they say quiet but theres only so much you can do. why do you need a generator anyways? and yeah it probably would disturb the people in your apartment.
Q: I recently seperated the generator from the engine and replaced the rear main oil seal on the engine the electric generator was only moved back about 16-18 inches to access rear main seal. job went well with no problems after completeing job I turned down rpms to about 1000 rpm It was put back in service They use it to power up refer containers from the harbor. the next day I check it and they had turned up rpms to ??? as fast as it would run and 12 refer units running off it oh it's 480 volt well it ran for a week non stop and broke down and of corse it was my fault all i did was unbolt drive plate on front of rotor from flywheel of engine .est to repair is 6,000 could this be my fault after it ran for a week or caused from hi rpms and heat related possibley
If they need a scapegoat, you're it. However if it ran for 168 hours on a diesel engine and things were not RE-torqued/double checked
Q: Hi.My diesel electric generator has a sticker that says Change oil every 100hrs. Use 10w-30 grade CC. But I can't find this oil anywhere. The closest I have found are 10w-30 Mobil1 synthetic oil (API SM/CF) and 15w-40 Pennzoil gold (with diesel protection, API CJ, CI, CF etc. /SM). Which one should I use?Thanks!
I beleive that CC is obsolete. Search diesel engine oil and find the one that matches your engine type.
Q: I want to power a water heater, a blower fan, and a small water pump continuously with a diesel generator run on Biodiesel. Is it possible to set up a system of some deep cycle batteries that will carry the load for say 1/2 hour or 1 hour and have the generator kick on automatically when the voltage drops to charge the batteriesthis way the generator will not be run continuously. What would you need to set this up? Anything besides what I have mentioned?Josh
What is the amp draw of the appliances how big are the batters and what is the output of the generator? too many variables for a good answer
Q: I am looking for a portable propane generator primarily as a home backup. I have a couple models in mind but have no clue about the quality. they seem to have good reviews, but wanted to ask in here anyways. i'm looking at the Sportsman GEN7000LP or Powerland PD3G8500E Tri-Fuel. anyone have experience with either of these? or can recommend a similarly capable brand/model?
Why a propane unit? Propane cost more per gallon that gasoline or diesel. If you have access to natural gas it would make more sense.
Q: Hi. I need to buy a diesel generator to run my house on. We have to run at least 3 ACs at a time. The ACs consume roughly 1500W with a surge power of 4500W.Here's my question. If I get a 12KW rated generator, does that mean that each phase can only handle 4000 KW, therefore not even enough to start an AC? i was given this formula by a sales man KVASQRT3 X V X iCan you shed some light on this problem?Greetings from Iran
Is the house wired 3 phase or split phase or single phase? Very few houses are wired for 3 phase power. Iran uses 230/240 VAC 50Hz So from that, you need a single phase 240 VAC 50 Hz generator. A 12 kW generator at 240 volts would supply 50 amps. I'd run that to a breaker panel (if you don't already have one) and then run 10 amp lines with a 10 amp breaker to each AC. That leaves you with quite a few amps to run other appliances. You got off on a 3 phase tangent for some reason you aren't telling, but I don't think that is the way you want to go. hope that helps. .

Send your message to us

This is not what you are looking for? Post Buying Request