• CHL/CHLF(T) Horizontal Multistage Stainless Steel Water Centrifugal Pump System 1
  • CHL/CHLF(T) Horizontal Multistage Stainless Steel Water Centrifugal Pump System 2
  • CHL/CHLF(T) Horizontal Multistage Stainless Steel Water Centrifugal Pump System 3
CHL/CHLF(T) Horizontal Multistage Stainless Steel Water Centrifugal Pump

CHL/CHLF(T) Horizontal Multistage Stainless Steel Water Centrifugal Pump

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
400 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1. Description

  1>Horizontal multistage design with stainless steel stamping welding impeller and diffuser,three different type of choice.

  2>Single phase motor up to 2.2kw,Class F and IP55 motor is standard.

  3>Standard supply for liquid temperature up to 70 degree centigrade,high temperature pump are available on request.

 

2. Application

  1>cooling water system

  2>agriculture

  3>domestic water supply

  4>general industrial services

  5>washing

  6>enviroment protection

 

3. Performance range

  capacity: Q up to 32m3/h

  head H up to 110 degree centigrade

  speed: n 2900rpm or 3500rpm

  power: P up to 55kw *2

 

4. Standard material

  All the parts contact with liquid made of 304 stainless steel on request.The pump head and suction & discharge can be  made of cast iron on request too.

 

5. RFQ

1> What's the difference for CHL and CHLF(T) type?

    CHL pumps have an inlet and outlet chamber which is made by stainless steel. CHLF(T) is just the section type. 

2> Do you have any variable motor for these pumps?

     Yes, we have. For the variable motor, the frequence can be changed as the customers' request. If the range is between 30~50Hz, the fan can be just connected with the shaft. And if the frequency is below 30Hz, then the fan has to have another separated power. The variable speed motor would be used for solar energy or some other similar situation with the unstable power. 

3> How about the Delivery time?

     Actually, this would be depending on the quantity. If it is just small order, 1 week would be fine. For bigger quantity, the delivery would be also less then 20 days. But for the varible speed ones, it will be taking some more time, normally it will be more than a month.  


CHL/CHLF(T) Horizontal Multistage Stainless Steel Water Centrifugal Pump

CHL/CHLF(T) Horizontal Multistage Stainless Steel Water Centrifugal Pump


Q: How much water does the water ring vacuum pump run for an hour? If there is no steam separator, does the water vaporize?
For example: water storage is relatively small, it needs to reduce the temperature of the heat exchanger. If the tank is relatively large, it does not need cooling water circulation pump again when the temperature is very low, there is no need to heat exchanger. So you need to ask how much water this is not OK.In a soda separator problem:
Q: How many millimeters is the diameter of the water outlet of the four inch pump?
This question is of no practical significance. The user does not care about this figure. The concern should be the nominal diameter, which is fitted with flanges and pipes. Moreover, the pump shell is cast iron, the inside diameter is not processed, and there is no matching parts, there is only one manufacturing size.
Q: What is the lift of diaphragm pump?
Hello, pneumatic diaphragm pump head is liquid, the energy obtained through the pump is called the head, it is related to the flow rate and pump speed, liquid density.Please adopt.
Q: There are second cutting, third cutting, why three times?
There are 2 situations, first, for example, a XXXX-160 type pump head 32, flow 100, motor 15kW, according to the model we need to cut a become head 28, flow rate of 88, this time, in addition to cutting the impeller, the pump or the original pump motor, became 11kW this is, re designed a new model, namely XXXX-160A, but most structural components did not change. In the same way, we want to design a XXXX-160B that makes the head 24 and the flow rate 80, then we just need to cut the impeller again and match the smaller (7.5kW) motor (the motor bracket needs to be redesigned). In general, multiple cutting impellers are designed to expand and enrich the model. Second, the actual use, if you think the flow head is too large, but also can be cut to make it smaller to adapt to practical applications. But the 2 and 3 cuts you ask are the first.
Q: Why should I pump the pump before starting the centrifugal pump?
1., if it is backward flow, it is not pumping;2., if the pump is installed underwater (such as submersible sewage pump), it is not pumping;3. pump is for installation in the form of suction. If no diversion irrigation pump, then the pump is full of air quality, air density is less than water, the pump will not be inside the gas out, the pump pressure will not be far less than the atmospheric pressure, the water will not be pressed into the pump to pump through irrigation formed inside the closed environment, the pump will start water out will cause local vacuum, entrance external water pressure into the pump is in inside and outside differential pressure, complete water movement. (vacuum water diversion is directly through the vacuum pump pumping the air in the pump, resulting in internal and external pressure difference, the external water pressure in the internal and external pressure is press into the inlet of the pump. The principle is the same as the pump. A standard atmosphere of =10m water column.)
Q: What is the displacement of the pump? Flow? What is the volume efficiency and mechanical efficiency of the pump?
Mechanical efficiency: the ratio of theoretical torque to actual torque of the pump.
Q: What is the difference between centrifugal pump and positive displacement pump?
The centrifugal pump is usually driven by an impeller, and the head has a functional relationship with the flow rate. Positive displacement pump is gear or piston drive, each stroke output flow is constant, and the head does not matter, the pressure head can be infinite.
Q: Pump operator's responsibility 10Sharing the rules, responsibilities, etc..
3. master the operating rules of the pump operation, and make sure the pump position is reasonably determined. Do a good job of site investigation, find out, pay attention to.4. master the working principle and basic technical parameters of the delivery pump. Obey the command of production dispatcher to ensure the completion of production tasks.5., according to the number of tanker at the scene, determine the pumping speed, in order to ensure the continuity of pouring.6. normal pumping, the discharge rate should be uniform, to prevent uneven discharge, resulting in pressure pipe gas plug, and thus lead to pipe or pipe explosion accident.
Q: How many concrete pump tube diameter
The pump is generally divided into 125 and 150 two, the inner diameter is 125mm and 150mm. And the two kinds of each have high and low pressure points. Low pressure type type 125 pump for the pipeline diameter is phi 133,
Q: Metering pumps related matters
Rotate to stroke length 100% position. This allows the kit to rotate to the back of the drain hole and align the bottom of the pump. Adjust the hydraulic end and diaphragm to the proper position during the pump operation.The duration of the pulse may not be long enough for the reaction time. With respect to the standard pulse width 80msec, the flow monitor pulse width expansion can be activated, increasing the pulse width to 300msec. Activate the smart switch, remove the cover fixed circuit board, remove the jumper X-1. This activates the extended function and allows more time before the failure instructions.Metering pump installed from the exhaust pump head, the use of self suction liquid imbibition. Keep the suction line as short as possible.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords