• CHL/CHLF(T) Horizontal Multistage Stainless Steel Centrifugal Pump with High Quality System 1
  • CHL/CHLF(T) Horizontal Multistage Stainless Steel Centrifugal Pump with High Quality System 2
  • CHL/CHLF(T) Horizontal Multistage Stainless Steel Centrifugal Pump with High Quality System 3
CHL/CHLF(T) Horizontal Multistage Stainless Steel Centrifugal Pump with High Quality

CHL/CHLF(T) Horizontal Multistage Stainless Steel Centrifugal Pump with High Quality

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
3000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1. Description

  1>Horizontal multistage design with stainless steel stamping welding impeller and diffuser,three different type of choice.

  2>Single phase motor up to 2.2kw,Class F and IP55 motor is standard.

  3>Standard supply for liquid temperature up to 70 degree centigrade,high temperature pump are available on request.

 

2. Application

  1>cooling water system

  2>agriculture

  3>domestic water supply

  4>general industrial services

  5>washing

  6>enviroment protection

 

3. Performance range

  capacity: Q up to 32m3/h

  head H up to 110 degree centigrade

  speed: n 2900rpm or 3500rpm

  power: P up to 55kw *2

 

4. Standard material

  All the parts contact with liquid made of 304 stainless steel on request.The pump head and suction & discharge can be  made of cast iron on request too.

 

5. RFQ

1> What's the difference for CHL and CHLF(T) type?

    CHL pumps have an inlet and outlet chamber which is made by stainless steel. CHLF(T) is just the section type. 

2> Do you have any variable motor for these pumps?

     Yes, we have. For the variable motor, the frequence can be changed as the customers' request. If the range is between 30~50Hz, the fan can be just connected with the shaft. And if the frequency is below 30Hz, then the fan has to have another separated power. The variable speed motor would be used for solar energy or some other similar situation with the unstable power. 

3> How about the Delivery time?

     Actually, this would be depending on the quantity. If it is just small order, 1 week would be fine. For bigger quantity, the delivery would be also less then 20 days. But for the varible speed ones, it will be taking some more time, normally it will be more than a month.  

CHL/CHLF(T) Horizontal Multistage Stainless Steel Centrifugal Pump with High Quality

CHL/CHLF(T) Horizontal Multistage Stainless Steel Centrifugal Pump with High Quality


Q:What are the characteristics of the piston pump?
1 、 built in overvoltage protection and flow correction system.6 、 large screen LCD display.7. The well designed exhaust device can effectively remove the bubbles in the liquid.8, flow and pressure settings can be memory, and PLC communication (custom).
Q:What is the dry running protector of screw pump? What's the principle and function? Thank you
When the temperature reaches a certain value, the signal is transmitted to the electric control box through a dry running protector, and the electric control box is used to stop the screw pump so as to protect the screw pump.
Q:What is the pump, how to classify, mainly used in where?
2. other classification of pumpsThe pump can be divided into two parts according to the position of the pump shaft:1) vertical pump2) horizontal pumpDivided by the number of suction ports:1) single suction pump (single suction pump);2) double suction pump (double, suction, pump)According to the prime mover of the drive pump:1) electric pumps2) steam turbine pump3) diesel engine pump[other details]
Q:Water pump outlet valve sequence
In order to prevent the generation of water hammer when the pump stops the damage to the rubber head, should be immediately set rubber head pump outlet, the gate valve and the check valve is not a very convincing reason to decide the order of habits in our hospital order rubber head, check valve, gate valve1. Check valve located in front of the pump, I do not know what the significance is too great to think of.2. The actual installation sequence shall be: soft fittings, check valves, gate valves. The pressure gauge is best installed on the water outlet of the pump, but it must be in front of the check valve.Reason: 1) the soft joint is used to reduce vibration. The connection between the pump and the piping system, of course.2) normal work, the gate valve is not operating, and the check valve is frequent action, so the probability of maintenance is larger, when the maintenance of the pump closed, the water outlet valve can be maintained without affecting the normal operation of the system.3) the pressure gauge is installed in the check valve, which can prevent the impact and damage of water hammer on the pressure gauge.
Q:What are the main performance parameters of hydraulic pumps?
Displacement and flowDisplacement refers to the pump (or motor) every turn a week, by the size of the sealing chamber geometry variable discharge (or enter) the volume of liquid, commonly used unit is ml/r (ml / rev). Displacement can be changed as a variable pump (or variable motor), and the displacement can not be changed into a quantitative pump (or a quantitative motor).Actual flow is the amount of flow at the outlet (or inlet) when the pump (or motor) is operating. As the pump itself leaks, the actual flow is less than the theoretical flow. As the motor itself has an internal leakage, to achieve the specified speed, in order to compensate the leakage, the actual flow of input must be greater than the theoretical flow.
Q:Why should I pump the pump before starting the centrifugal pump?
1., if it is backward flow, it is not pumping;2., if the pump is installed underwater (such as submersible sewage pump), it is not pumping;3. pump is for installation in the form of suction. If no diversion irrigation pump, then the pump is full of air quality, air density is less than water, the pump will not be inside the gas out, the pump pressure will not be far less than the atmospheric pressure, the water will not be pressed into the pump to pump through irrigation formed inside the closed environment, the pump will start water out will cause local vacuum, entrance external water pressure into the pump is in inside and outside differential pressure, complete water movement. (vacuum water diversion is directly through the vacuum pump pumping the air in the pump, resulting in internal and external pressure difference, the external water pressure in the internal and external pressure is press into the inlet of the pump. The principle is the same as the pump. A standard atmosphere of =10m water column.)
Q:Brief description of centrifugal pump on / off operation
Two, centrifugal pump start(1) the pump entrance valve fully open, start motor, outlet valve fully closed, fully check operation of pump.(2) when the pump outlet pressure is higher than the operation pressure, the outlet valve is gradually opened to control the flow and pressure of the pump.(3) check whether the motor current is within the rated value, such as the pump in the rated flow operation, and the motor overload should stop the pump inspection.
Q:Must the water pump in the tank be all soaked in water?
Need a submersible pump in the water, but it is not entirely like this, I have to work for a long time no problem in water, but there is a problem you should pay attention to the water pump, at least in half, or stop when the smoke is not on water.
Q:If you use an ordinary 15W submersible pump, put it in the tank, if the leakage, the fish will hang it?
Submersible pump even if it really leakage, it will not cause the fish electric shock. The so-called leakage is the submersible pump wire or shell broken, live parts and water contact, the most extreme test is a fire line directly into the fish tank
Q:How to maintain and repair the booster pump of pipeline pump?
Two 、 troubleshootingfaultReasonRemoval method1. water pump does not produce waterThe water injected into the water pump is not enough, the rotation direction is not right, and the impeller passage is blocked.Pump water into the pump, pass through the impeller runner, adjust the direction of rotation.2. pump flow is insufficientThe pump speed is too low, part of the blockage, the total lift pump is higher than the rated value, the damage to the impeller.Clean the water pump and pipe, replace the impeller, increase the pump shaft revolutions, adjust the outlet valve.3. lack of outlet pressureThere is air in the liquid, the speed is too low, the impeller is damaged and the outlet valve is open.Exclude liquid air, increase the pump speed, replace the impeller, adjust the small outlet valve.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords