Flexible Duct Steel Wire of CNBM in China
- Loading Port:
- China main port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 m.t.
- Supply Capability:
- 1 m.t./month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Quick Details
Steel Grade: | Q195,Q235,18A,20#,45#,60#,65#,70#,72B,80#,82B,65Mn | Standard: | AISI,ASTM,BS,DIN,GB,JIS | Wire Gauge: | 0.3mm to 13.0mm |
Place of Origin: | Zhejiang China (Mainland) | Type: | Drawn Wire | Application: | spring,rope,spoke,binding,clip,fencing... |
Alloy Or Not: | Non-alloy | Special Use: | Cold Heading Steel | Model Number: | Q195,Q235,SAE1008,1010,1020,45#,60#,65#,70#,72B,80#,82B,65Mn |
Brand Name: | HUIXIN | black, bright, galvanized...: | SMOOTH |
Packaging & Delivery
Packaging Detail: | COMMON COIL, Z2 COIL, COIL WITH CARDBOARD WHEEL, COIL WITH PLASTIC WHEEL & WOODEN WHEEL,AND SO ON |
Delivery Detail: | USUALLY 10 DAYS AFTER RECEIVE YOUR DEPOSIT OR L/C |
Specifications
-Steel wire 0.3-13.0mm
GB4357-89
Dia mm | Deviation mm | T/S MPa | ||
B | C | D | ||
0.3 | ±0.014 | 2010-2400 | 2300-2700 | 2640-3040 |
0.32 | ±0.018 | 1960-2350 | 2250-2650 | 2600-2990 |
0.35 | 1960-2350 | 2250-2650 | 2600-2990 | |
0.4 | 1910-2300 | 2250-2650 | 2600-2990 | |
0.45 | 1860-2260 | 2200-2600 | 2550-2940 | |
0.5 | 1860-2260 | 2200-2600 | 2550-2940 | |
0.55 | 1810-2210 | 2150-2550 | 2500-2890 | |
0.6 | 1760-2160 | 2110-2500 | 2450-2840 | |
0.65 | ±0.02 | 1760-2160 | 2110-2500 | 2450-2840 |
0.7 | 1710-2110 | 2060-2450 | 2450-2840 | |
0.8 | 1710-2060 | 2010-2400 | 2400-2840 | |
0.9 | 1710-2060 | 2010-2350 | 2350-2750 | |
1.0 | 1660-2010 | 1960-2300 | 2300-2690 | |
1.2 | ±0.03 | 1620-1960 | 1910-2250 | 2250-2550 |
1.4 | 1620-1910 | 1860-2210 | 2150-2450 | |
1.6 | 1570-1860 | 1810-2160 | 2110-2400 | |
1.8 | 1520-1810 | 1760-2110 | 2010-2300 | |
2.0 | 1470-1760 | 1710-2010 | 1910-2200 | |
2.2 | 1420-1710 | 1660-1960 | 1810-2110 | |
2.50 | 1420-1710 | 1660-1960 | 1760-2060 | |
2.80 | 1370-1670 | 1620-1910 | 1710-2010 | |
3.00 | 1370-1670 | 1570-1860 | 1710-1960 | |
3.20 | ±0.038 | 1320-1620 | 1570-1810 | 1660-1910 |
3.50 | 1320-1620 | 1570-1810 | 1660-1910 | |
4.00 | 1320-1620 | 1520-1760 | 1620-1860 | |
4.50 | 1320-1570 | 1520-1760 | 1620-1860 | |
5.00 | 1320-1570 | 1470-1710 | 1570-1810 | |
5.50 | 1270-1520 | 1470-1710 | 1570-1810 | |
6.00 | 1220-1470 | 1420-1660 | 1520-1760 | |
6.50 | ±0.045 | 1220-1470 | 1420-1610 | |
7.00 | 1170-1420 | 1370-1570 | ||
8.00 | 1170-1420 | 1370-1570 | ||
9.00 | 1130-1320 | 1320-1520 | ||
10.0 | 1130-1320 | 1320-1520 | ||
11.0 | ±0.055 | 1080-1270 | 1270-1470 | |
12.0 | 1080-1270 | 1270-1470 |
- Q:My friend is buying under-wired bras and what are they and the heavily- wired bra?
- bras that have wire on the bottom to support your boobs they make your boobs look better under shirts sometimes fuller depending on the bra
- Q:I have just learned how to make some pretty cool bracelets out of telephone wire and i would like to know where to find more telephone wire. Could someone tell me where i might be able to find some?
- We okorder / (...click on the category Plastic Wire, Telephone Wire...) HTH, Diane B.
- Q:im assuming red to red and black to black? but then what about the extra green and white wires in the iphone cable? where do they go?
- Those are the USB wires. For a charger, they need connected through voltage setting resistors.
- Q:(PRIOR TO READING, I SUGGEST YOU LOOK AT THE IMAGES AS IT WILL MAKE THINGS A WHOLE LOT EASIER TO UNDERSTAND)I purchased 2 neons from Repco. That run off your cigerette lighter with an adaptor. They worked fine, until my friend got in my car, and accidentally dropped something on the adaptor which caused it to malfunction, and bam, my in-car neons (placed up under the dash, near where your feet rest) went out.
- wire is wire. If it really is silver then theoretically it should conduct electrcitiy better than copper. But that doesn't really matter much. wire is wire. all it needs to be able to do is carry the electrical current. If wiring truly is your problem, then that will work fine.
- Q:first wire change
- Depends on how many little kinks he's putting in it. Also depends on how fast he works, if your wire needs a lot of work or a little, and if he already has an idea of what he wants to do or if he's just guessing along the way. It shouldn't take longer for him to make the actual kinks than it does the remove and replace the wire. That's a little more labor intensive and can take about 5-10 minutes for each wire. The whole thing, uninterrupted might last 30-45 minutes.
- Q:What wires plug in under the center console of a 2000 firebird, there is a 5 wire plug that I can't figure out where it plugs into
- +1 for the LS1Tech site. I am a member and there is tons of info there and great people to help you out.
- Q:How can it be possible to create a high voltage and have a small gauge wire? Example: 3gj or 3000mw in a small wire (just an example)
- The limit on the size of current carrying conductor is the heat produced due to power losses which leads to failure of the conductor, the power losses depends mainly on the square of the current (P=I^2R) so in power transmission voltage is being stepped-up to high values to decrease current and, in turn, the conductor size is reduced. Theoretically we could step-up the voltage to extremely high values and thus we could have a very thin wire to carry the small current because P=VI so at constant power as voltage V increases the current I decreases. But there are also limits for stepping up voltage as the insulation is directly affected by the voltage. In case of insultaed cables, the insulating material (PVC or XLPE) will fail if the voltage reaches its Break-down Voltage. In case of overhead transmission lines (OHTLs) the conductors are insulated by air between phases and the suspended disk insulators each has their own breakdown voltages. It should be noted that safety regulations determine a safe distance of 1 cm per Kv that you should keep from high voltage conductor. This means that for a consductors carries voltage of 500kv you should allow a distance of 5 meters away from it for your safety as its magnetic effect is not exlusive on its surface but for a distance around it proportional with the voltage.
- Q:I am getting these 2 CVR 12's 4 ohm dvc and i am wiring them for a 2 ohm load (parallel). When you run a wire from voice coil 1 positive to voice coil 2 positive, then to amp. and the same for negative, what is the wire that is connecting the voice coils? is it a power wire, ground wire, speaker wire? please help!
- Speaker okorder
- Q:so there are 3 different wires coming into the switch. 1 black wire and 2 white wires going to the attic fan (i assume one for high and one for low). the power seems to be coming from the black wire which has inside of it, one white wire (neutral) one black wire (hot) and one bare wire (ground).. the same for the 2 white wires. the switch goes up (^) for high and down (v) for low and has 3 places to attach the wires to. the top, the bottom and the middle.. can someone tell me how to wire this damn thing?
- I think you are describing NM cables(Romex). What you have is: 1 black romex with a hot(black) a neutral(white) and a bare ground. and 2 white romexs with a black, white, bare each. right so far? What you probably have is the hot and neutral going to the switch j-box (black romex) and the 2 white romexs go from the switch to the fan j-box. I think I need more info. Do you have a test meter? Are you sure the black romex is the Hot and Neutral? When the wires are disconnected are there other things that don't have power to them? Did you undo the neutral splice? If you could send this info I think I can walk you thru it.
- Q:The 1992 camry wiring diagram comes up to about 19 wires, my stock stereo that I unplugged from the back on the harness has about 14, and it has 3 black wires 2 brow, 2 green and 2 red, the others only have one wire, why is this?
- Each okorder /... That site should bring you some clarity.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Flexible Duct Steel Wire of CNBM in China
- Loading Port:
- China main port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 m.t.
- Supply Capability:
- 1 m.t./month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products