AAAC conductor / All-Aluminum Alloy Conductor
- Loading Port:
- China main port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 200 m
- Supply Capability:
- 20000 m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
BARE CONDUCTOR AS PER ASTM STANDARDS
1.1 AAAC-6201
All-Aluminum Alloy Conductor.
STANDARDS
AAAC-6201 bare conductor meets or exceeds the following ASTM standards:
l B-398 Aluminum-Alloy 6201-T81 Wire for Electrical Purposes.
l B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
CONSTRUCTION
Aluminum alloy 6201 wires. concentrically stranded.
Code word | Size (kcmil) | Strand-ing | Diameter (ins.) | Weight per 1000 ft. (Lbs) | Rated strength (Lbs) | Resistance /1000 ft. | Allowable ampacity+ (Amps) | ACSR with equiv.diam. | Approx EC cond. with equivalent resistance | |||
Indivi- dual wire | Complete conductor | DC at 20℃ | AC at 75℃ | Size | Stranding (AL/STL) | |||||||
Akron | 30.58 | 7 | 0.0661 | 0.198 | 28.5 | 1110 | .659 | .785 | 107 | 6 | 6/1 | 6 |
Alton | 48.69 | 7 | 0.0834 | 0.250 | 45.4 | 1760 | .414 | .493 | 143 | 4 | 6/1 | 4 |
Ames | 77.47 | 7 | 0.1052 | 0.316 | 72.2 | 2800 | .260 | .310 | 191 | 2 | 6/1 | 2 |
Azusa | 123.3 | 7 | 0.1327 | 0.398 | 115.0 | 4460 | .163 | .195 | 256 | 1/0 | 6/1 | 1/0 |
Anaheim | 155.4 | 7 | 0.1490 | 0.447 | 144.9 | 5390 | .130 | .154 | 296 | 2/0 | 6/1 | 2/0 |
Amherst | 195.7 | 7 | 0.1672 | 0.502 | 182.5 | 6790 | .103 | .123 | 342 | 3/0 | 6/1 | 3/0 |
Alliance | 246.9 | 7 | 0.1878 | 0.563 | 230.2 | 8560 | .0816 | .0973 | 395 | 4/0 | 6/1 | 4/0 |
Butte | 312.8 | 19 | 0.1283 | 0.642 | 291.7 | 11000 | .0644 | .0769 | 460 | 266.8 | 26/7 | 266.8 |
- Q:What is the best tool or method in your opinion to locate cable damage causing current leak on several cables supplying outdoor lighting as detected by a tripping GFCI breaker. (Or water in a light obviously). Is there a meter that can measure that directly with the power off?
- I usually have one of my kids lick their finger and run it along the cable. a lightbulb in the mouth helps.
- Q:I have a Karcher power washer which was left outside over night. An animal chewed threw the power cable and so is unusable. I was wondering how to re-connect the power cord together, safely. I do not want to cross wires and use electrical tape. I was thinking of using a connector, but unsure of whether to use a two pinned or three pinned connector.
- You can install a plug on the cord to replace the one that was chewed off. Choose one with the same number of prongs as the cord has wires (2 or 3). Be sure to attach each wire to the correct terminal! Splicing the cord is also OK, and tape would not be a problem if applied properly, but I prefer to use heat-shrink tubing. When I do a top-grade splice, I first twist the wires tightly together without making a tail, then I solder them.
- Q:I've heard of a new file transferring tool which transfers file through power cables and I need to know about how it worksand how does it apply the pulses or the waves to the frequency of the power cables!!
- No it is not possible to transfer the data through power cables, Ask what you actually want to do i will solve your problem.
- Q:Excuse me, what is the difference between submarine power cables and general buried power cables? What is the difference between the calculated current carrying capacity of the submarine power cable and the general calculation of the current carrying capacity of the cable? More
- 1 TV inside the 400V filter capacitor damage 2 audio and video cable connection is not good or poor quality 3 you put the TV volume dots, set-top box volume can be improved
- Q:Brief description of the difference between cable and cable.
- Will not interfere with the middle there is no strong electricity! Cable no problem, may be the cable signal as before, you can use a waterproof tape wrapped up ah, do not exposed ah! If the wall with 220V power, then it is easy to string into the TV, the consequences ...
- Q:Is the power cable considered a fixed asset?
- According to the total number of meters, such as where to where a total of how many kilometers (meters). Power system fixed assets asset management software - TU Teng fixed asset management software.
- Q:Wire and cable should be used in parallel when the attention
- Have to fight trumpet, mainly to protect the cable jacket is not scratched
- Q:I have plugged my old laptop power cable into my USB hard drive, and now it does not work at all. Have I completed fried the circuits? Is there any way to get the data back if I have please?Thanks for any advice you can offer.
- The circuits might have gone on the hard disc. But data platters would not be gone. You might get back your data, but it involves a great expenditure. You have to send the disc to the manufacturer for retrieval of data. Unless the data is very important, I would suggest junking the disc.
- Q:i bought a car from some guy..he had 2 amps but he took out one...he had the power cable running from one amp to the other. i just recently bought another amp and i was wondering if its safe to do this.he said it was working fine..he was powering 2 10 subwoofers..thats what im planning to do
- it is safe...but not the best method it really depends on the guage of the wire....best to have a single large gauge running to a distribution block then a wire for each amp comming out of the block to were the amps are. blocks are fairly cheap (usually less than 20 bucks) and safer...plus you get better power flow and 1 amp is not sucking all the power before it gets to the other
- Q:Power Cable Check Well b-type covers show what?
- Indicating the carrying capacity of the covers, according to "People's Republic of China town construction industry standards" to understand that: steel fiber reinforced concrete inspection covers are divided into A, B, C, D four
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
AAAC conductor / All-Aluminum Alloy Conductor
- Loading Port:
- China main port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 200 m
- Supply Capability:
- 20000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Related keywords