Quick Detail:

1.Cummins Industrial Diesel Engine :4BTA3.9-G2,6BTA5.9-G2,KTA19-G3

2.Electronic Governor,Water Cooled

3.Original Stamford AC Alternator:UCI224E ,UCI274D,UCI274H

4.English interface,LED screen and touch buttons controller

 

 

Specifications:

 

Genset Model

Prime Power

Standby Power

Engine

Fuel Consumption

Cylinder No.

Displacement

Bore X Stroke

KW

KVA

KW

KVA

(g/kwh)

 (L )

(mm)

GNRC30

20

25

24

30

4B3.9-G

≤229

4

3.9

102*120

GNRC35

24

30

28

35

4BT3.9-G2

≤214

4

3.9

102*120

GNRC56

40

50

45

56

4BTA3.9-G2

≤215

4

3.92

102*120

GNRC63

45

56

50

63

4BTA3.9-G2

≤215

4

3.92

102*120

 GNRC70

50

63

56

70

6BT5.9G2

≤215

6

5.88

102*120

GNRC106

78

98

85

106

6BT5.9G2

≤215

6

5.88

102*120

GNRC125

90

113

100

125

6BT5.9G2

≤215

6

5.88

102*120

GNRC150

104

130

120

150

6BT5.9G2

≤215

6

5.88

102*120

GNRC165

120

150

132

165

6CTA8.3-G2

≤210

6

8.3

114*135

GNRC200

140

175

160

200

6CTA8.3-G2

≤210

6

8.3

114*135

GNRC225

160

200

180

225

6CTAA8.3-G2

≤210

6

8.3

114*135

GNRC275

200

250

220

275

6LTAA8.9-G2

≤210

6

8.3

114*135

GNRC313

220

275

250

313

NTA855-G1A

≤206

6

14

140*152

GNRC350

250

313

275

350

NTA855-G2

≤207

6

14

140*152

GNRC400

280

350

310

400

NTA855-G4

≤208

6

14

140*152

GNRC413

300

375

330

413

NTAA855-G7

≤206

6

14

140*152

GNRC450

320

400

360

450

NTAA855-G7A

≤206

6

14

140*152

GNRC500

360

450

400

500

KTA19-G3

≤203

6

18.9

159*159 

GNRC550

400

500

440

550

KTA19-G4

≤203

6

18.9

159*159 

GNRC605

440

550

484

605

KTAA19-G6

≤204

6

18.9

159*159 

GNRC625

450

563

500

625

KTAA19-G7

≤204

6

18.9

159*159 

GNRC700

500

625

560

700

KTA38-G

≤206

12

37.8

159*159 

GNRC712

520

650

570

712

QSK19-G3

≤206

6

19

159*159 

GNRC800

580

720

640

800

KTA38-GA

≤209

12

37.8

159*159 

GNRC825

600

750

660

825

KTA38-G2

≤210

12

37.8

159*159 

GNRC888

640

800

710

888

KTA38-G2B

≤210

12

37.8

159*159 

GNRC975

720

900

780

975

KTA38-G2A

≤210

12

37.8

159*159 

GNRC1075

800

1000

860

1075

KTA38-G5

≤202

12

37.8

159*159 

GNRC1375

1000

1250

1100

1375

KTA50-G3

≤215

16

50.3

159*159

GNRC1375

1100

1375

1310

1650

KTA50-G8

 ≤215

16

50.3

159*159

GNRC1650

1200

1500

1340

1675

KTA50-GS8

 ≤215

16

50.3

159*159

GNRC1675

1350

1688

1500

1875

QSK60-G3

 ≤215

16

60

159*159

GNRC1875

1500

1875

1650

2063

QSK60-G3

 ≤215

16

60

159*190

GNRC2063

1600

2000

1800

2250

QSK60-G4

 ≤215

16

60

159*190


 

Genset Features:

1. Genuine Commins industrial diesel engine

2. Radiator 40°C max, fans are driven by belt, with safety guard

3. Genuine stamford. Leroy somer, marathonm, engga alternator

4. Choice of manual/auto and AMF control panels and protection systems

5. Digital auto-start panel

6. Anti Vibration Suspension Absorber

7. Dry type air filter, fuel filter, oil filter

8. 10-hour operation base tank

9.Mould case circuit breaker

10. 24V DC start motor and storage battery

11. 24V charge alternator

12. 24V batteries, rack and cable

13. Rippl;e flex echaust pipe, exhaust siphon, flange, and muffler

14.   Comply with ISO and CE standards

15. All generator sets are gone through rigorous testing before beging released to the market place, including 50% load, 75% load, 100% load and all protection function(over speed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)

 

 

Engine Features:

1. Genuine Cummins industrial diesel engine

2. Multi-cylinder in-line or veer engine, 4-stroke, direct injection

3. Naturally aspirated, turbocharged, water cooled or turbocharged with air intercooler

4. Machinery or electronic governing

5. Fuel injection pump

6. Electric motor starting system

7. Forged steel crankshaft, cast iron cylinder and replaceable wet type cylinder liner

8. Low discharge, and low fuel consumption

9. Installed conveniently and maintain easily

 

 

Alternator Features:

1. World famous brand AC alternator: Leroy Somer, Stamford, Marathon, ENGGA

2. Brushless, 4 poles, rotation magnet

3. IP21-23(NEMA1) enclose is standard for all industrial alternators

4. H class insulation system

5. AVR self-regulated, voltage regulation rate: ≤±1%

6. Simple installation and maintenance with easy access to terminals, rotating diodes and coupling bolts

7. Wide range of flange adaptors and single bearing disc coupling
8. Radio interference restraining accords with the stipulation of VDE0875-N and ISO8528

9. Moisture proof, sand-proof, dustproof, salt-proof and vibration-proof
Digital Control panel

Controller Brand: Smartgen, Deepsea,ComAp
Control Panel: English interface,LED screen and touch buttons.

Main Functions:
1- Display loading power, voltage, currenct, frequency, speed, temperature, oil pressure, running time etc.

2- Warning when low or high voltage, low or high frequency, over current, over or low speed, low or over battery voltage etc.

3- Over load protection, over/under frequency protection, over/under/imbalance voltage protection, and low oil shutdown

 

Super Soundproof/Silent Box:

1. Excellent ventilation

2. Oil tank mounted on base frame for 12 Hours working

3. Highly Corrosion Resistant construction

4. Excellent Access for Maintenance

5. Security and Safety

6. 1m<80DBA / 7m<70DBA

 

Q:Precautions for water cooled motor
(1) water-cooled air-cooled motor during normal operation of temperature should not exceed the permitted limits. When running, the personnel on duty should always pay attention to monitor the temperature of each part. (2) monitoring water-cooled air-cooled motor load current. Water-cooled air-cooled motor overload or failure occurs, can cause the stator current surge, water-cooled air-cooled motor overheating. Electrical equipment should have current meter monitor water-cooled air-cooled motor load current, the normal operation of water-cooled air-cooled motor load current shall not exceed the rated current value stipulated in the nameplate. (3) to monitor the change of supply voltage, frequency and voltage unbalance degree. The power supply voltage and frequency is too high or too low, three-phase voltage imbalance will cause current unbalance, can cause water-cooled air-cooled motor overheating or other abnormal phenomena. Current unbalance degree should not exceed 10%.
Q:There is a difference between the electric motor and the other motors
The electric motor is also a three-phase asynchronous motor that drives direct current through the inverter to the three-phase square wave current to drive the motor spinning
Q:How is the servo motor parameter chosen
Call the servo factory, find a sample data, you can choose the requirements of your equipment
Q:What is the difference between a three-phase asynchronous motor and a regular motor?
Three-phase asynchronous motor cooling fan is fixed on the motor shaft, the same as the rotation speed of the motor, low frequency is run, the fan is running at low speed, the cooling capacity drops greatly, the heat generated by the motor can't send out, serious when burning motor. The structure and pressure capacity of the inverter motor are specially designed to accommodate high speed and high harmonics. Motor has the branch of general motor and frequency conversion motor, called main appearance is different from ordinary motor frequency conversion motor frequency conversion motor is packed with centrifugal fan forced cooling, this ensures the motor at low frequency and high frequency heat dissipation is good, and frequency conversion motor internal structure can adapt to the high frequency operation of specific working frequency range see nameplate. General motors generally allow only running under 50hz.
Q:What is the difference between a step motor and an ordinary motor
The step motor is in the position control general motors are usually the speed control and the control of the two is different. Position control means that you can set the number of times you want your motor to rotate (a circle of 360 degrees), and speed control means how much your motor is going to turn/minute. This can be seen in the low speed of the step motor, which is the high speed of the motor.
Q:What is the difference between servo motor and general motors?
Servo motors belong to precision motors, and the smaller power, have their own Angle feedback signal, each round will produce more than 10000 Angle signal, extremely accurate, generally used in precision machining, special equipment, use to have a high precision requirement, general motors just a equipment of electrical energy into kinetic energy, there is no other auxiliary functions
Q:How do ordinary motors achieve precise positioning
Because there is no position sensor, you can't locate it. If you need to locate, you can only use servo motor or excitation machine. Electric machinery is a kind of electromagnetic device that can be converted or transmitted by electromagnetic induction law. In the circuit, the letter M (old standard D) is used. Its main function is to generate drive torque as the power source of electrical or mechanical power. The generator is represented by the letter G in the circuit. Its main function is to use mechanical energy to convert into electricity, and the most commonly used is to use heat energy and water energy to push the rotor of the generator to generate electricity.
Q:Is there any difference between motor and motor? A positive answer
Electric motors include motors and generators. The general term for generators and motors is that they are conceptually different. However, certain motors, such as synchronous motors, are generally more used as generators, but can also be used directly as motors. Asynchronous motors are more used for motors, but by adding simple peripheral components, they can also be used as generators.
Q:What is the difference between an energy-saving motor and a general motor
Ordinary motors are ubiquitous in daily life, but energy efficient generators are also beginning to emerge when energy is highly developed. And more and more people are choosing to save electric motors, so what is the difference between an energy-efficient motor and a regular motor? First, the output power of the ordinary motor is less than that of the energy-saving machine. The output power of the ordinary motor is only 50% of the input power, and the energy-saving motor can reach more than 90%. The next year, power issues. The electric motor will be powered by the power supply, and the energy saving motor will turn on the power and the feet will not use electricity. In a society where energy is scarce, we should conserve energy and save money for ourselves. Energy efficient motors can do that. The performance characteristics of high efficiency and energy-saving motors are introduced as follows: 1. Completely based on domestic raw materials. The method of low uncertainty test is used to calibrate the efficiency of the measured results. Contrast with the normal Y series: losses of 15% to 25% and efficiency up 2.5% to 4%. 4. With the improved ventilation systems using highly efficient energy-saving fan of energy-saving motor air gap, the flux density distribution of reasonable design, make the motor efficiency index reaches more than GB18613-2006 grade 2 energy efficiency standard.
Q:The governor has changed a new one, with the governor to zero, but the motor is still turning! The motor has a different sound, such as the sound of iron and iron friction!
Check the speed line. There may be a circuit breakers. There's no problem with the excitation coils. The motor is abnormal and the bearing is damaged.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords