Power Genset Diesel Generator 30kw - 600kw With Cummins Engine
- Loading Port:
- Guangzhou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 1500 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Power Genset Diesel Generator 30kw - 600kw With Cummins Engine
Quick Detail:
1.Cummins Industrial Diesel Engine :4BTA3.9-G2,6BTA5.9-G2,KTA19-G3
2.Electronic Governor,Water Cooled
3.Original Stamford AC Alternator:UCI224E ,UCI274D,UCI274H
4.English interface,LED screen and touch buttons controller
Specifications:
Genset Model | Prime Power | Standby Power | Engine | Fuel Consumption | Cylinder No. | Displacement | Bore X Stroke | ||
KW | KVA | KW | KVA | (g/kwh) | (L ) | (mm) | |||
GNRC30 | 20 | 25 | 24 | 30 | 4B3.9-G | ≤229 | 4 | 3.9 | 102*120 |
GNRC35 | 24 | 30 | 28 | 35 | 4BT3.9-G2 | ≤214 | 4 | 3.9 | 102*120 |
GNRC56 | 40 | 50 | 45 | 56 | 4BTA3.9-G2 | ≤215 | 4 | 3.92 | 102*120 |
GNRC63 | 45 | 56 | 50 | 63 | 4BTA3.9-G2 | ≤215 | 4 | 3.92 | 102*120 |
GNRC70 | 50 | 63 | 56 | 70 | 6BT5.9G2 | ≤215 | 6 | 5.88 | 102*120 |
GNRC106 | 78 | 98 | 85 | 106 | 6BT5.9G2 | ≤215 | 6 | 5.88 | 102*120 |
GNRC125 | 90 | 113 | 100 | 125 | 6BT5.9G2 | ≤215 | 6 | 5.88 | 102*120 |
GNRC150 | 104 | 130 | 120 | 150 | 6BT5.9G2 | ≤215 | 6 | 5.88 | 102*120 |
GNRC165 | 120 | 150 | 132 | 165 | 6CTA8.3-G2 | ≤210 | 6 | 8.3 | 114*135 |
GNRC200 | 140 | 175 | 160 | 200 | 6CTA8.3-G2 | ≤210 | 6 | 8.3 | 114*135 |
GNRC225 | 160 | 200 | 180 | 225 | 6CTAA8.3-G2 | ≤210 | 6 | 8.3 | 114*135 |
GNRC275 | 200 | 250 | 220 | 275 | 6LTAA8.9-G2 | ≤210 | 6 | 8.3 | 114*135 |
GNRC313 | 220 | 275 | 250 | 313 | NTA855-G1A | ≤206 | 6 | 14 | 140*152 |
GNRC350 | 250 | 313 | 275 | 350 | NTA855-G2 | ≤207 | 6 | 14 | 140*152 |
GNRC400 | 280 | 350 | 310 | 400 | NTA855-G4 | ≤208 | 6 | 14 | 140*152 |
GNRC413 | 300 | 375 | 330 | 413 | NTAA855-G7 | ≤206 | 6 | 14 | 140*152 |
GNRC450 | 320 | 400 | 360 | 450 | NTAA855-G7A | ≤206 | 6 | 14 | 140*152 |
GNRC500 | 360 | 450 | 400 | 500 | KTA19-G3 | ≤203 | 6 | 18.9 | 159*159 |
GNRC550 | 400 | 500 | 440 | 550 | KTA19-G4 | ≤203 | 6 | 18.9 | 159*159 |
GNRC605 | 440 | 550 | 484 | 605 | KTAA19-G6 | ≤204 | 6 | 18.9 | 159*159 |
GNRC625 | 450 | 563 | 500 | 625 | KTAA19-G7 | ≤204 | 6 | 18.9 | 159*159 |
GNRC700 | 500 | 625 | 560 | 700 | KTA38-G | ≤206 | 12 | 37.8 | 159*159 |
GNRC712 | 520 | 650 | 570 | 712 | QSK19-G3 | ≤206 | 6 | 19 | 159*159 |
GNRC800 | 580 | 720 | 640 | 800 | KTA38-GA | ≤209 | 12 | 37.8 | 159*159 |
GNRC825 | 600 | 750 | 660 | 825 | KTA38-G2 | ≤210 | 12 | 37.8 | 159*159 |
GNRC888 | 640 | 800 | 710 | 888 | KTA38-G2B | ≤210 | 12 | 37.8 | 159*159 |
GNRC975 | 720 | 900 | 780 | 975 | KTA38-G2A | ≤210 | 12 | 37.8 | 159*159 |
GNRC1075 | 800 | 1000 | 860 | 1075 | KTA38-G5 | ≤202 | 12 | 37.8 | 159*159 |
GNRC1375 | 1000 | 1250 | 1100 | 1375 | KTA50-G3 | ≤215 | 16 | 50.3 | 159*159 |
GNRC1375 | 1100 | 1375 | 1310 | 1650 | KTA50-G8 | ≤215 | 16 | 50.3 | 159*159 |
GNRC1650 | 1200 | 1500 | 1340 | 1675 | KTA50-GS8 | ≤215 | 16 | 50.3 | 159*159 |
GNRC1675 | 1350 | 1688 | 1500 | 1875 | QSK60-G3 | ≤215 | 16 | 60 | 159*159 |
GNRC1875 | 1500 | 1875 | 1650 | 2063 | QSK60-G3 | ≤215 | 16 | 60 | 159*190 |
GNRC2063 | 1600 | 2000 | 1800 | 2250 | QSK60-G4 | ≤215 | 16 | 60 | 159*190 |
Genset Features:
1. Genuine Commins industrial diesel engine
2. Radiator 40°C max, fans are driven by belt, with safety guard
3. Genuine stamford. Leroy somer, marathonm, engga alternator
4. Choice of manual/auto and AMF control panels and protection systems
5. Digital auto-start panel
6. Anti Vibration Suspension Absorber
7. Dry type air filter, fuel filter, oil filter
8. 10-hour operation base tank
9.Mould case circuit breaker
10. 24V DC start motor and storage battery
11. 24V charge alternator
12. 24V batteries, rack and cable
13. Rippl;e flex echaust pipe, exhaust siphon, flange, and muffler
14. Comply with ISO and CE standards
15. All generator sets are gone through rigorous testing before beging released to the market place, including 50% load, 75% load, 100% load and all protection function(over speed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)
Engine Features:
1. Genuine Cummins industrial diesel engine
2. Multi-cylinder in-line or veer engine, 4-stroke, direct injection
3. Naturally aspirated, turbocharged, water cooled or turbocharged with air intercooler
4. Machinery or electronic governing
5. Fuel injection pump
6. Electric motor starting system
7. Forged steel crankshaft, cast iron cylinder and replaceable wet type cylinder liner
8. Low discharge, and low fuel consumption
9. Installed conveniently and maintain easily
Alternator Features:
1. World famous brand AC alternator: Leroy Somer, Stamford, Marathon, ENGGA
2. Brushless, 4 poles, rotation magnet
3. IP21-23(NEMA1) enclose is standard for all industrial alternators
4. H class insulation system
5. AVR self-regulated, voltage regulation rate: ≤±1%
6. Simple installation and maintenance with easy access to terminals, rotating diodes and coupling bolts
7. Wide range of flange adaptors and single bearing disc coupling
8. Radio interference restraining accords with the stipulation of VDE0875-N and ISO8528
9. Moisture proof, sand-proof, dustproof, salt-proof and vibration-proof
Digital Control panel
Controller Brand: Smartgen, Deepsea,ComAp
Control Panel: English interface,LED screen and touch buttons.
Main Functions:
1- Display loading power, voltage, currenct, frequency, speed, temperature, oil pressure, running time etc.
2- Warning when low or high voltage, low or high frequency, over current, over or low speed, low or over battery voltage etc.
3- Over load protection, over/under frequency protection, over/under/imbalance voltage protection, and low oil shutdown
Super Soundproof/Silent Box:
1. Excellent ventilation
2. Oil tank mounted on base frame for 12 Hours working
3. Highly Corrosion Resistant construction
4. Excellent Access for Maintenance
5. Security and Safety
6. 1m<80DBA / 7m<70DBA
- Q: Can ordinary motors be matched with inverters?
- Can, but not the long run under low frequency, which can't run for a long time in 30 hz, because: 1. The inverter output is not a standard sine wave, the large amount of harmonic, harmonic exacerbate motor hair machine; The cooling fan of the normal motor and the motor coaxial, the cooling fan speed decreases and the cooling effect is decreased when the motor is running at low speed.
- Q: What is the difference between a general motor and a converter machine?
- In general, I do not want to post the discussion of sexual articles in BBS, for two reasons. First, the large articles are too long and do not fit the conversational style of BBS. Second, it's not original, it's not vivid enough. To quote "work," it's called "glamour." But upstairs, that's good. The answer to the topic is simple and comprehensive. Point now. Essence of praise.
- Q: The advantage of the pole motor relative to the ordinary motor
- She points to the pole machine: Reasonable structure design flexible lead direction, the bonnet motor junction box can rotate and install itself Excellent protective grade of low noise, low vibration and high performance
- Q: What is the difference between a single phase motor and a two-phase machine?
- You mean should be the difference between the single-phase motor and three-phase motor, the difference between them is to use the power supply is different, single-phase motor using household electricity, three-phase industrial three-phase electric motor.
- Q: What is the difference between a three-phase asynchronous motor and a regular motor?
- Three-phase asynchronous motor cooling fan is fixed on the motor shaft, the same as the rotation speed of the motor, low frequency is run, the fan is running at low speed, the cooling capacity drops greatly, the heat generated by the motor can't send out, serious when burning motor. The structure and pressure capacity of the inverter motor are specially designed to accommodate high speed and high harmonics. Motor has the branch of general motor and frequency conversion motor, called main appearance is different from ordinary motor frequency conversion motor frequency conversion motor is packed with centrifugal fan forced cooling, this ensures the motor at low frequency and high frequency heat dissipation is good, and frequency conversion motor internal structure can adapt to the high frequency operation of specific working frequency range see nameplate. General motors generally allow only running under 50hz.
- Q: The difference between plateau motor and ordinary motor
- Medium altitude increases, the air cooling effect is reduced, heat dissipation ability to drop, increase temperature, every 1000 m, elevated temperature to increase by 3-10%, therefore, to fix the motor temperature rise limit.
- Q: The difference between brushless dc motor and plain dc motor, where is its advantage
- Brushless dc motor consists of motor subject and drive, which is a typical electromechanical integrated product. The stator winding of the motor is a three-phase symmetric star connection, which is similar to the three-phase asynchronous motor. The rotor of the motor is attached to the magnetized permanent magnet, which detects the polarity of the motor rotor and has a position sensor in the motor. Drive consists of power electronic devices and integrated circuit, its function is: accept the motor start, stop, brake signal, to control the motor start, stop, and the brake; To accept the signal of position sensor and the positive and reverse signal to control the flow of the power pipe of the inverter bridge to produce continuous torque. Accept the speed and speed feedback signals to control and adjust the speed. Provide protection and display, etc. Because of brushless dc motor based on self-control type operation, so don't like frequency control of motor speed synchronous motor overload start under plus startup winding on the rotor, also won't generate oscillation and step out when load mutation.
- Q: Does the motor swing around?
- First can tear down load belt try, if still swinging, that is the motor is out of the problem to see not fixed, or the inside of the bearing looseness, if there is something wrong with the bearing should be supposed to send sound or with fixed load. If you put a belt on it, it's probably a belt that's not tuned and you can figure out how to do it.
- Q: Why does the direct start-up of high power motors affect the voltage of the grid
- Because of the asynchronous motor starting, the rotor has not turned up, the stator rotating magnetic field cutting speed relative to the rotor conductors, in rotor induction electric potential is very big, so the current is very big, if starting directly from grid, starting current can reach 4 to 7 times the rated current, and is the most current inductive current, this would have had a big impact on the grid: 1) the large starting current will be produced on the transmission line, the larger voltage drop; 2) because so much of the starting current, most of it is a perceptual current, will cause a demagnetization effect on the grid, and will also cause the grid voltage to fluctuate.
- Q: What is the difference between the decelerating step motor and the normal step motor?
- The decelerating step motor is a gearbox installed in front of the step motor. Lower the speed of the step motor to increase torque.
Send your message to us
Power Genset Diesel Generator 30kw - 600kw With Cummins Engine
- Loading Port:
- Guangzhou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 1500 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords