50Hz Genset Diesel Generator 40kw To 600kw With Perkins Engine

Ref Price:
Loading Port:
Guangzhou
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
1500 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

50Hz Genset Diesel Generator 40kw To 600kw With Perkins Engine

 

 

Quick Detail:

1. 15kva ,60kva 90kva 120kva Perkins diesel engine 

2. Leroysomer alternator 230V/400V,3phase  Brushless, 4 poles

3. Smartgen digital control panel with ATS

4. 10-hour operation base tank

 

 

Specifications:

 

Genset Model

Prime Power

Standby Power

Engine

Fuel Consumption

Cylinder No.

Displacement

Bore X Stroke

KW

KVA

KW

KVA

(g/kwh)

 (L )

(mm)

GNRP10

7

9

8

10

403D-11

≤252

3

1.131

77*81

GNRP15

10

13

12

15

403D-15

≤264

3

1.496

84*94

GNRP23

16

20

18

23

404D-22

≤243

4

2.216

84*100

GNRP33

24

30

26

33

1103A-33G

≤210

3

3.3

105*127

GNRP50

36

45

40

50

1103A-33TG1

≤212

3

3.3

105*127

GNRP65

48

60

52

65

1103A-33TG2

≤211

3

3.3

105*127

GNRP73

52

65

58

73

1104A-44TG1

≤207

4

4.4

105*127

GNRP88

64

80

70

88

1104A-44TG2

≤213

4

4.4

105*127

GNRP103

75

94

82

103

1006TG1A

≤210

6

5.99

100*127

GNRP150

110

138

120

150

1006TAG

≤205

6

5.99

100*127

GNRP165

120

150

132

165

1006TAG2

≤205

6

5.99

100*127

GNRP225E

165

206

180

225

1306C-E87TAG3

≤220

6

8.7

117*136

GNRP250E

180

225

200

250

1306C-E87TAG4

≤219

6

8.7

117*136

GNRP259E

188

235

207

259

1306C-E87TAG5

≤221

6

8.7

117*136

GNRP275E

200

250

220

275

1306C-E87TAG6

≤223

6

8.7

117*136

GNRP344E

250

313

275

344

2206C-E13TAG2

≤201

6

14.6

137*165

GNRP388E

280

350

310

388

2206C-E13TAG2

≤198

6

14.6

137*165

GNRP450E

320

400

360

450

2206C-E13TAG3

≤201

6

14.6

137*165

GNRP500E

360

450

400

500

2506C-E15TAG1

≤216

6

15

137*171

GNRP550E

400

500

440

550

2506C-E15TAG2

≤211

6

15

137*171

GNRP625E

450

563

500

625

2806A-E18TAG1A

≤196

6

18.13

145*183

GNRP700E

508

635

560

700

2806A-E18TAG2

≤203

6

18.13

145*183

GNRP800

580

725

640

800

4006-23TAG2A

≤199

6

22.921

160*190

GNRP900

640

800

720

900

4006-23TAG3A

≤200

6

22.921

160*190

GNRP1000

720

900

800

1000

4008-TAG1A

≤206

8

30.561

160*190

GNRP1125

818

1022

900

1125

4008-TAG2A

≤208

8

30.561

160*190

GNRP1375

1000

1250

1100

1375

4012-46TWG2A

≤212

12

45.482

160*190

  

 

  Genset Features:

1. Genuine UK industrial diesel engine

2. Radiator 40°C max, fans are driven by belt, with safety guard

3. Genuine stamford. Leroy somer, marathonm, engga alternator

4. Choice of manual/auto and AMF control panels and protection systems

5. Digital auto-start panel

6. Anti Vibration Suspension Absorber

7. Dry type air filter, fuel filter, oil filter

8. 10-hour operation base tank

9.Mould case circuit breaker

10. 24V DC start motor and storage battery

11. 24V charge alternator

12. 24V batteries, rack and cable

13. Rippl;e flex echaust pipe, exhaust siphon, flange, and muffler

14. Comply with ISO and CE standards

15. All generator sets are gone through rigorous testing before beging released to the market place, including 50% load, 75% load, 100% load and all protection function(over speed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)

 

Engine Features:

1. Genuine UK Perkins industrial diesel engine

2. Multi-cylinder in-line or veer engine, 4-stroke, direct injection

3. Naturally aspirated, turbocharged, water cooled or turbocharged with air intercooler

4. Machinery or electronic governing

5. Fuel injection pump

6. Electric motor starting system

7. Forged steel crankshaft, cast iron cylinder and replaceable wet type cylinder liner

8. Low discharge, and low fuel consumption

9. Installed conveniently and maintain easily

 

Alternator Features:

1. World famous brand AC alternator: Leroy Somer, Stamford, Marathon, ENGGA

2. Brushless, 4 poles, rotation magnet

3. IP21-23(NEMA1) enclose is standard for all industrial alternators

4. H class insulation system

5. AVR self-regulated, voltage regulation rate: ≤±1%

6. Simple installation and maintenance with easy access to terminals, rotating diodes and coupling bolts

7. Wide range of flange adaptors and single bearing disc coupling

8. Radio interference restraining accords with the stipulation of VDE0875-N and ISO8528

9. Moisture proof, sand-proof, dustproof, salt-proof and vibration-proof

 

Digital Control panel

Controller Brand: Smartgen, Deepsea,ComAp

Control Panel: English interface,LED screen and touch buttons.

Main Functions:

1- Display loading power, voltage, currenct, frequency, speed, temperature, oil pressure, running time etc.

2- Warning when low or high voltage, low or high frequency, over current, over or low speed, low or over battery voltage etc.

3- Over load protection, over/under frequency protection, over/under/imbalance voltage protection, and low oil shutdown

 

Soundproof/Silent Box:

1. Excellent ventilation

2. Oil tank mounted on base frame for 12 Hours working

3. Highly Corrosion Resistant construction

4. Excellent Access for Maintenance

5. Security and Safety

6. 1m<80DBA / 7m<70dba< span="">

 

Optional:

1. Trailer type

2. Soundproof / water proof

3. ATS (automatic transfer switch)

4. Parallel system

5. Remote system

 

PMC System:

1. Standard 23 pitch windings avoid excessive neutral current

2. Permanent magnet generator system provides constant excitation under all condition

3. Optional accessories available for easy paralleling with mains or other generators

4. AVR auto voltage regulation, auto exciter, auto adjustment

 

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Speed regulating motor is not adjusted
This is basic rule out the problem of speed governor, the problem may be broken in speed resistance speed governor is set to zero, the resistance should be in maximum, or feedback signal input connection circuit, it is suggested that can be replaced. Speed machine: governor (called) is a kind of automatic adjustment device, according to the change of the diesel engine load, it automatically increase or decrease in fuel injection pump oil, the diesel engine to run at a steady speed. Governor has been in the industry dc motor speed regulation, conveyor belt speed, lamplight illume mediation, computer power supply cooling, dc fan, etc., used widely. Governor according to its working principle is different, can be divided into mechanical, pneumatic, hydraulic, mechanical pneumatic compound, complex mechanical hydraulic and electronic, and other forms.
Q:Direct drive motor control mode
A direct drive motor is an electric motor that does not require a transmission mechanism, which drives the load directly. Normally this type of motor has no output shaft and is mechanically different from other motors. But there is no difference between electromagnetic structures and other motors. There is a box and an unframed simple point which means there is no shell.
Q:Precautions for water cooled motor
Pay attention to the smell of water-cooled air-cooled motor, vibration and noise. Winding due to temperature too gao will send insulation focal flavour. Some faults, especially the mechanical failure, will soon be reflected as the vibration and noise, so the smell coke or found abnormal vibration or scratches or the hum of the super-large or other noise, power check immediately. (5) always check the heat of the bearing, the oil leakage, change the lubricating oil regularly, and the roller bearing grease should not exceed 70% of the bearing room volume. (6) of wound rotor type water-cooled air-cooled motor, check the contact between the brush and slip ring, brush wear and spark, such as spark serious must clean up the surface of the collector ring, timely and correct the brush spring pressure. (7) keep water-cooled air-cooled motor internal clean, there is no water, oil and debris fell into internal water-cooled air-cooled motor. Air inlet must be kept clear of water-cooled air-cooled motor.
Q:How does the heat of dc motor control
First of all, you want to let us know whether you have a brush or a brush before you can determine if your fever is likely to be caused by what
Q:What's wrong with the rotary roller
It shouldn't be the sound of the motor turning. That's an electric motor with an oversize load that's buzzing; And then the protective device of the motor starts to move, which is what we call the tripping. If you don't jump, the motor will keep turning. That is, the motor is idle; That's the pulley or gear that's connected to the motor and it's not working; That's it. There are only two cases.
Q:How is the rated current of the three-phase machine calculated?
Three-phase motor power P = 1.732 UIcos phi, cos phi (power factor) between 0.7 and 0.95, the greater the power of the motor, the greater the power factor, which can be evaluated at 0.85. So I = P/(1.732 * U * cos phi) = 4800 / (1.732 * 440 * 0.8) = 1.732 A, 11.5 A you say may be the whole compressor power or are you using current meter measuring current, if the current meter measurement, so the motor is overload. Voltage is 440 v, can know you this motor is not domestic, domestic general is 380 (400 v), rated 400 v voltage can be used in our country, of course, because the motor is a range of voltage, rated voltage 400 v motor between 360-440 - v can be used. In China there is 440 v, you said general voltage is 380 v, 440 v rated voltage, so when calculating the electric current cannot use the above data, and should change the 440 to 440, the calculated current is 9.1 A. Here's a rough calculation, because 1.732 * 380 * 0.8 = 520, close to 500, so under the three-phase 380V voltage, Current I = P (kilowatt) / 2.
Q:Why does the direct start-up of high power motors affect the voltage of the grid
Because of the asynchronous motor starting, the rotor has not turned up, the stator rotating magnetic field cutting speed relative to the rotor conductors, in rotor induction electric potential is very big, so the current is very big, if starting directly from grid, starting current can reach 4 to 7 times the rated current, and is the most current inductive current, this would have had a big impact on the grid: 1) the large starting current will be produced on the transmission line, the larger voltage drop; 2) because so much of the starting current, most of it is a perceptual current, will cause a demagnetization effect on the grid, and will also cause the grid voltage to fluctuate.
Q:What is the difference between a three-phase asynchronous motor and a regular motor?
Three-phase asynchronous motor cooling fan is fixed on the motor shaft, the same as the rotation speed of the motor, low frequency is run, the fan is running at low speed, the cooling capacity drops greatly, the heat generated by the motor can't send out, serious when burning motor. The structure and pressure capacity of the inverter motor are specially designed to accommodate high speed and high harmonics. Motor has the branch of general motor and frequency conversion motor, called main appearance is different from ordinary motor frequency conversion motor frequency conversion motor is packed with centrifugal fan forced cooling, this ensures the motor at low frequency and high frequency heat dissipation is good, and frequency conversion motor internal structure can adapt to the high frequency operation of specific working frequency range see nameplate. General motors generally allow only running under 50hz.
Q:What is the difference between explosion-proof motors and ordinary motors?
The difference between explosion-proof motor and ordinary motor: Explosion-proof motors are commonly used in inflammable and explosive situations. 2, the seal of explosion proof electrical connection box is better than ordinary motor. The protection level of explosion proof motor is IP55, and the ordinary motor has IPIP23, IP44, IP54, IP55 and IP56, so it can be distinguished from the shape. Explosion-proof electric motor is a kind of motor that can be used in inflammable and explosive factory. Explosion-proof motors are mainly used in coal mines, oil and gas, petrochemical and chemical industries. In addition, in textile, metallurgy, city gas, transportation, grain oil processing, paper, medicine and other departments are also widely used. Explosion-proof motor is the main power equipment, which is used to drive pumps, fans, compressors and other driving machines.
Q:All the other motors don't change, how does the rated torque and speed change?
Do you specify the thickness of the laminated rotor? Laminated thickness increase and will not affect the speed (speed and logarithmic and frequency) and rated torque will be slightly ascending, maximum torque, rated current decreases.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range