• 50Hz Genset Diesel Generator 40kw To 600kw With Perkins Engine System 1
  • 50Hz Genset Diesel Generator 40kw To 600kw With Perkins Engine System 2
50Hz Genset Diesel Generator 40kw To 600kw With Perkins Engine

50Hz Genset Diesel Generator 40kw To 600kw With Perkins Engine

Ref Price:
get latest price
Loading Port:
Guangzhou
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
1500 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

50Hz Genset Diesel Generator 40kw To 600kw With Perkins Engine

 

 

Quick Detail:

1. 15kva ,60kva 90kva 120kva Perkins diesel engine 

2. Leroysomer alternator 230V/400V,3phase  Brushless, 4 poles

3. Smartgen digital control panel with ATS

4. 10-hour operation base tank

 

 

Specifications:

 

Genset Model

Prime Power

Standby Power

Engine

Fuel Consumption

Cylinder No.

Displacement

Bore X Stroke

KW

KVA

KW

KVA

(g/kwh)

 (L )

(mm)

GNRP10

7

9

8

10

403D-11

≤252

3

1.131

77*81

GNRP15

10

13

12

15

403D-15

≤264

3

1.496

84*94

GNRP23

16

20

18

23

404D-22

≤243

4

2.216

84*100

GNRP33

24

30

26

33

1103A-33G

≤210

3

3.3

105*127

GNRP50

36

45

40

50

1103A-33TG1

≤212

3

3.3

105*127

GNRP65

48

60

52

65

1103A-33TG2

≤211

3

3.3

105*127

GNRP73

52

65

58

73

1104A-44TG1

≤207

4

4.4

105*127

GNRP88

64

80

70

88

1104A-44TG2

≤213

4

4.4

105*127

GNRP103

75

94

82

103

1006TG1A

≤210

6

5.99

100*127

GNRP150

110

138

120

150

1006TAG

≤205

6

5.99

100*127

GNRP165

120

150

132

165

1006TAG2

≤205

6

5.99

100*127

GNRP225E

165

206

180

225

1306C-E87TAG3

≤220

6

8.7

117*136

GNRP250E

180

225

200

250

1306C-E87TAG4

≤219

6

8.7

117*136

GNRP259E

188

235

207

259

1306C-E87TAG5

≤221

6

8.7

117*136

GNRP275E

200

250

220

275

1306C-E87TAG6

≤223

6

8.7

117*136

GNRP344E

250

313

275

344

2206C-E13TAG2

≤201

6

14.6

137*165

GNRP388E

280

350

310

388

2206C-E13TAG2

≤198

6

14.6

137*165

GNRP450E

320

400

360

450

2206C-E13TAG3

≤201

6

14.6

137*165

GNRP500E

360

450

400

500

2506C-E15TAG1

≤216

6

15

137*171

GNRP550E

400

500

440

550

2506C-E15TAG2

≤211

6

15

137*171

GNRP625E

450

563

500

625

2806A-E18TAG1A

≤196

6

18.13

145*183

GNRP700E

508

635

560

700

2806A-E18TAG2

≤203

6

18.13

145*183

GNRP800

580

725

640

800

4006-23TAG2A

≤199

6

22.921

160*190

GNRP900

640

800

720

900

4006-23TAG3A

≤200

6

22.921

160*190

GNRP1000

720

900

800

1000

4008-TAG1A

≤206

8

30.561

160*190

GNRP1125

818

1022

900

1125

4008-TAG2A

≤208

8

30.561

160*190

GNRP1375

1000

1250

1100

1375

4012-46TWG2A

≤212

12

45.482

160*190

  

 

  Genset Features:

1. Genuine UK industrial diesel engine

2. Radiator 40°C max, fans are driven by belt, with safety guard

3. Genuine stamford. Leroy somer, marathonm, engga alternator

4. Choice of manual/auto and AMF control panels and protection systems

5. Digital auto-start panel

6. Anti Vibration Suspension Absorber

7. Dry type air filter, fuel filter, oil filter

8. 10-hour operation base tank

9.Mould case circuit breaker

10. 24V DC start motor and storage battery

11. 24V charge alternator

12. 24V batteries, rack and cable

13. Rippl;e flex echaust pipe, exhaust siphon, flange, and muffler

14. Comply with ISO and CE standards

15. All generator sets are gone through rigorous testing before beging released to the market place, including 50% load, 75% load, 100% load and all protection function(over speed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)

 

Engine Features:

1. Genuine UK Perkins industrial diesel engine

2. Multi-cylinder in-line or veer engine, 4-stroke, direct injection

3. Naturally aspirated, turbocharged, water cooled or turbocharged with air intercooler

4. Machinery or electronic governing

5. Fuel injection pump

6. Electric motor starting system

7. Forged steel crankshaft, cast iron cylinder and replaceable wet type cylinder liner

8. Low discharge, and low fuel consumption

9. Installed conveniently and maintain easily

 

Alternator Features:

1. World famous brand AC alternator: Leroy Somer, Stamford, Marathon, ENGGA

2. Brushless, 4 poles, rotation magnet

3. IP21-23(NEMA1) enclose is standard for all industrial alternators

4. H class insulation system

5. AVR self-regulated, voltage regulation rate: ≤±1%

6. Simple installation and maintenance with easy access to terminals, rotating diodes and coupling bolts

7. Wide range of flange adaptors and single bearing disc coupling

8. Radio interference restraining accords with the stipulation of VDE0875-N and ISO8528

9. Moisture proof, sand-proof, dustproof, salt-proof and vibration-proof

 

Digital Control panel

Controller Brand: Smartgen, Deepsea,ComAp

Control Panel: English interface,LED screen and touch buttons.

Main Functions:

1- Display loading power, voltage, currenct, frequency, speed, temperature, oil pressure, running time etc.

2- Warning when low or high voltage, low or high frequency, over current, over or low speed, low or over battery voltage etc.

3- Over load protection, over/under frequency protection, over/under/imbalance voltage protection, and low oil shutdown

 

Soundproof/Silent Box:

1. Excellent ventilation

2. Oil tank mounted on base frame for 12 Hours working

3. Highly Corrosion Resistant construction

4. Excellent Access for Maintenance

5. Security and Safety

6. 1m<80DBA / 7m<70dba< span="">

 

Optional:

1. Trailer type

2. Soundproof / water proof

3. ATS (automatic transfer switch)

4. Parallel system

5. Remote system

 

PMC System:

1. Standard 23 pitch windings avoid excessive neutral current

2. Permanent magnet generator system provides constant excitation under all condition

3. Optional accessories available for easy paralleling with mains or other generators

4. AVR auto voltage regulation, auto exciter, auto adjustment

 

 

Q:Precautions for water cooled motor
Pay attention to the smell of water-cooled air-cooled motor, vibration and noise. Winding due to temperature too gao will send insulation focal flavour. Some faults, especially the mechanical failure, will soon be reflected as the vibration and noise, so the smell coke or found abnormal vibration or scratches or the hum of the super-large or other noise, power check immediately. (5) always check the heat of the bearing, the oil leakage, change the lubricating oil regularly, and the roller bearing grease should not exceed 70% of the bearing room volume. (6) of wound rotor type water-cooled air-cooled motor, check the contact between the brush and slip ring, brush wear and spark, such as spark serious must clean up the surface of the collector ring, timely and correct the brush spring pressure. (7) keep water-cooled air-cooled motor internal clean, there is no water, oil and debris fell into internal water-cooled air-cooled motor. Air inlet must be kept clear of water-cooled air-cooled motor.
Q:What is the solution to other circuit boards when the servo motor is turned on
Are you strictly grounded? Does your servo power supply have a power connection (no filter) with the switch power source of the control system? Or the quality of your switch? Personal suggestion: the reason that the power of switch power supply is relatively large, you buy a switching power supply in Taiwan to try the power supply.
Q:Who is more powerful than the average motor and servo?
Who is more powerful than the average motor and servo? The torque size of the motor is related to the efficiency of the motor, and the efficiency of the servo motor is higher than that of the ordinary motor, so the servo motor is more powerful.
Q:The difference between the frequency converter and the ordinary motor
There is no difference between the motor and the motor of the converter is the three-phase asynchronous motor. However, the speed of the machine can be adjusted to achieve energy saving and constant pressure.
Q:The difference between servo motor and general motor?
The insulation level, which is usually F or higher, strengthens the insulation strength of the ground and turns, especially considering the ability of insulation to withstand shock voltage. 2) to the problem of vibration and noise of the motor, the motor should be fully considered component and overall rigidity, trying to improve its natural frequency, in order to avoid and every force wave resonance phenomenon. 3) cooling mode: the general adoption of forced ventilation cooling, the main motor cooling fan is driven by an independent motor. To prevent shaft current measures, the bearing insulation measures should be applied to the capacity exceeding 160KW motors. Mainly produces magnetic circuit asymmetry, also can produce shaft current, while the rest of the high frequency component generated by the current role in combination, shaft current will increase greatly, which can lead to bearing damage, so often insulation measures. For constant power frequency converter motor, the special lubricating grease should be used to compensate the temperature of the bearings when the speed is over 3000 / min.
Q:The problem of speed regulating motor and general motors
With frequency converter, of course, will not shorten the life of the motor, ordinary motor frequency converter will be used to take, no problem at all, music fountain is with motor with frequency converter
Q:What is the difference between a single phase motor and a two-phase machine?
Single-phase motor is to use the 220 power supply, three-phase motor is to use the three phase line of power supply, no dual phase motor, only electric welding machine is to use two phase 380 v electricity
Q:Does the frequency conversion machine speak louder than the ordinary motor?
No, only when the frequency is low. It's basically the same as a normal machine in 10HZ.I hope my answer will help you
Q:The governor has changed a new one, with the governor to zero, but the motor is still turning! The motor has a different sound, such as the sound of iron and iron friction!
The governor has changed a new one, but the motor is still turning! This is basic rule out the problem of speed governor, the problem may be broken in speed resistance speed governor is set to zero, maximum resistance should be in, or associated feedback signal input lines (including feedback coil winding) local open circuit or short circuit. This self should have a multimeter check.
Q:What is the difference between the decelerating step motor and the normal step motor?
The decelerating step motor is the step motor of the decelerating mechanism. Adjust the torque. Some situations don't need fast speed but require great torque. There is also a large jump in the step motor at low speeds, which can be improved by adding a reducer.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords