• Deutz Genset Diesel Generator 1600kw With 24V DC Start Motor System 1
  • Deutz Genset Diesel Generator 1600kw With 24V DC Start Motor System 2
Deutz Genset Diesel Generator 1600kw With 24V DC Start Motor

Deutz Genset Diesel Generator 1600kw With 24V DC Start Motor

Ref Price:
get latest price
Loading Port:
Guangzhou
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
1500 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

30kw to 1600kw Deutz Diesel Engine Generator

1. Deutz diesel Engine, 110v/220v Leroy alternator , 60Hz,

2. 24V DC start motor and storage battery

3. soundproof canopy , low noise

 

Deutz Genset Diesel Generator 1600kw With 24V DC Start Motor

 

Specifications:

Genset Model

Prime Power

Standby Power

Engine

Fuel Consumption

Cylinder No.

Displace

-ment

Bore X Stroke

Dimension         (L×B×H)mm

KW

KVA

KW

KVA

(g/kwh)

 (L )

(mm)

GNRD16A

12

15

14

16

F2L912

≤238

2

1.88

100*120

1200*710*1030

GNRD28A

20

25

22

28

F3L912

≤232

3

2.82

100*120

1380*710*1030

GNRD41A

30

38

33

41

F4L912

≤228

4

3.77

100*120

1560*710*1030

GNRD55A

40

50

44

55

F6L912

≤228

6

5.65

100*120

1730*760*1050

GNRD68A

50

62

55

68

F6L913

≤228

6

6.12

100*120

1730*760*1050

GNRD75A

54

68

60

75

F6L912T

≤228

6

6.12

100*120

1760*760*1150

GNRD96A

70

88

77

96

BF6L91C3

≤228

6

6.12

102*125

2200*840*1370

GNRD28

20

25

22

28

D226B-3D

≤215

3

3

105*120

1600*780*1150

GNRD55

40

50

44

55

TD226B-3D

≤215

3

3

105*120

1880*700*1300

GNRD70

50

63

55

70

TD226B-4D

≤215

4

4

105*120

1990*750*1300

GNRD110

80

100

88

110

TD226B-6D

≤215

6

6

105*120

2190*780*1350

GNRD150

100

125

110

150

TBD226B-6D

≤215

6

6

105*120

2330*780*1450

GNRD206

150

188

165

206

BF6M1013FCG2

≤202

6

7.15

108*130

2520*960*1670

GNRD250

180

225

200

250

BF6M1013FCG4

≤202

6

7.5

108*130

2600*960*1690

GNRD300

220

275

240

300

TBD234V8-1A

≤195

8

14.4

128*140

2900*1240*1710

GNRD388

280

350

310

388

TBD234V8-1B

≤195

8

14.4

128*140

2930*1240*1710

GNRD413

300

375

330

413

BF6M1015CP-LAG

≤196

6

11.9

132*145

2620*1160*1810

GNRD500

360

450

400

500

TBD234V12-1A

≤196

12

21.6

128*140

3610*1240*1850

GNRD563

400

500

450

563

BF8M1015CP-LAG2

≤196

8

15.8

132*145

3380*1340*1890

GNRD625

450

563

500

625

TBD604BL6-2A

≤196

6

26.6

170*195

3950*1550*2069

GNRD750

540

675

600

750

TBD604BL6-2B

≤197

6

26.6

170*195

3970*1550*2065

GNRD875

630

788

700

875

TD620L6-2B

≤196

6

26.6

170*195

4480*1716*2210

GNRD1100

800

1000

880

1100

TBD620V8-2A

≤187

8

35.4

170*195

4400*2060*2350

GNRD1400

1000

1250

1120

1400

TBD620V12-2A

≤187

12

53.2

170*195

4930*2210*2500

GNRD1875

1350

1688

1500

1875

TBD620V12-2C

≤187

12

53.2

170*195

5160*2210*2500

GNRD2250

1600

2000

1800

2250

TBD620V16-2A

≤188

16

70.8

170*195

5500*2220*2600

GNRD2750

2000

2250

2200

2750

TBD622V20-2A

≤187

20

99.8

170*215

6600*2300*2800

 

Generator Deutz Features:

 

1. Genuine Detuz diesel engine

2. Radiator 40°C max,fans are driven by belt, with safety guard

3. Original Leroy Somer, Stamford, Marathon, or ENGGA alternator

4. Choice of manual/auto and AMF control panels and protection systems

5. Digital auto-start panel

6. Anti Vibration Suspension Absorber

7. Dry type air filter, fuel filter, oil filter

8. 10-hour operation base tank

9. Mould case circuit breaker

10. 24V DC start motor and storage battery

11. 24V charge alternator

12. 24V batteries, rack and cable

13. Ripple flex exhaust pipe, exhaust siphon, flange, and muffler

14. Comply with ISO and CE standards.

15. All generator sets are gone through rigorous testing before being released to the market place, including 50% load, 75% load, 100% load , 110% load and all protection function (over speed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)

General Technical Data

1. Frequency: 50 & 60Hz

2. Phase: 3 Phase 4 Wire & 1 Phase 2 Wire

3. Voltage: 120/207V,127/220V,220/380V, 230/400V, 240/415V, etc

4. Small volume, light weight, low noise, low fuel consumption, water cooling with water tank

5. Monitoring meters and control switches

6. Protection provided for short, over-current, over-speed, high water temperature and low oil pressure

Control Panel:

 

1. Automatic control panel (AMF), LCD display

2. Four protection systems

3. Emergency stop 

 

Optional:

 

1. Trailer type

2. Soundproof / open type

3. ATS(automatic transfer switch

 

Q:What is an electric motor
Electric motors are powered by electric induction.I hope my answer will help you
Q:A 2.2 KW motor will require a lot of electricity a day
It is not accurate to calculate simply because you are not considering the load rate of the motor, and the load rate of the pump is less than 75%. The most accurate method is to install the meter.
Q:Direct drive motor control mode
The control board is the same as the general permanent magnet motor. The problem is you is to point to the need to control the motor start-stop, or to control the torque (your this kind of motor is primarily a torque motor), and you need to control analog or digital control. After certain, the circuit design is convenient. Need your motor driven load characteristics, work environment, such as the control response speed, accuracy, voltage, power, etc., and whether the high temperature, high humidity, high dust, high electromagnetic interference, etc., all of these have an effect on circuit design.
Q:The difference between a two-speed motor and a regular motor
It's a three-phase squirrel-cage motor, but the winding is not the same as a normal motor, with two sets of winding. It's going to be the same thing as having two polar Numbers, and you have two speeds.
Q:What is the difference between a general motor and a converter machine?
In general, I do not want to post the discussion of sexual articles in BBS, for two reasons. First, the large articles are too long and do not fit the conversational style of BBS. Second, it's not original, it's not vivid enough. To quote "work," it's called "glamour." But upstairs, that's good. The answer to the topic is simple and comprehensive. Point now. Essence of praise.
Q:Which is good for common motor and induction motor?
Induction motor, also called "asynchronous motor, the rotor put in a rotating magnetic field, under the effect of rotating magnetic field, to obtain a rotational torque, thus the rotor rotation. The rotor is a rotating conductor, usually in a squirrel-cage. It was invented by electrical engineer nikola tesla in 1887.
Q:The difference between ordinary motor and permanent magnet motor
The permanent magnet motor is the synchronous motor, which has a permanent magnet, which interacts with the magnetic field generated by the external power source and produces torque.
Q:The difference between pump motor and general motor?
The difference between pump motor and ordinary motor is mainly the shell of the motor and its protection, the oil pump motor casing is sealed explosion-proof type.
Q:The difference between brushless dc motor and plain dc motor, where is its advantage
Brushless dc motor and brushless dc motor is the difference between ordinary is as follows: 1, the brushless dc motor with integrated drive circuit commutation, ordinary brushless dc motor with brush and commutator with the reversing, keep the continuous rotation of the motors. The winding of brushless dc motor is the stator, the magnet is the rotor, and the common windings are the rotor, the electromagnet is the stator. The non-brush dc motor USES rare earth permanent magnet (nd-ti-boron permanent magnet) to achieve greater power and efficiency, and ordinary brush dc motor USES ferrite permanent magnet. The non-brushless dc motor is usually multi-groove, 6 slots, 9 slots, 12 slots, 24 slots, etc., the average brush dc motor has fewer slots, 3 slots, 5 slots, 7 slots etc. The company has shenzhen constant drive motor co., LTD.
Q:If the speed of a normal motor is adjusted by the frequency converter, the speed can exceed the rated speed, and if the current power is above the rated speed, what is the change in current power
Motor frequency control of motor speed and load, control system, closed loop control, open loop control, independent motor), which has no books can be used for direct access to information, because of the complexity of the situation. The output of the motor is lower than the rated speed, and the output of the motor is the output of the fixed torque. If, in the closed-loop control in main motor dynamic adjustment target rotation speed and torque of the motor, under the condition of the motor can meet the maximum load power, if be uniform, drag the project target motor with the higher level or lower level of drag torque is the same, and the final output linear velocity is given priority to with the main motor to work machine, tend to be the same.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords