3 Phase Perkins Genset Diesel Generator With 1606A-E93TAG5
- Loading Port:
- Guangzhou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 1500 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
15kva to 1500kva Perkins Genset With Stamford Alternator
1.UK imported Perkins diesel engine 1606A-E93TAG5 2206A-E13TAG2
2. AC alternator 220V/380V. 110V/220v, 127V/220V, 3phase , 50Hz
3.DSE control panel with AMF
3 Phase Perkins Genset Diesel Generator With 1606A-E93TAG5
Specifications:
Genset Model | Prime Power | Standby Power | Engine | Fuel Consumption | Cylinder No. | Displacement | Bore X Stroke | ||
KW | KVA | KW | KVA | (g/kwh) | (L ) | (mm) | |||
GNRP10 | 7 | 9 | 8 | 10 | 403D-11 | ≤252 | 3 | 1.131 | 77*81 |
GNRP15 | 10 | 13 | 12 | 15 | 403D-15 | ≤264 | 3 | 1.496 | 84*94 |
GNRP23 | 16 | 20 | 18 | 23 | 404D-22 | ≤243 | 4 | 2.216 | 84*100 |
GNRP33 | 24 | 30 | 26 | 33 | 1103A-33G | ≤210 | 3 | 3.3 | 105*127 |
GNRP50 | 36 | 45 | 40 | 50 | 1103A-33TG1 | ≤212 | 3 | 3.3 | 105*127 |
GNRP65 | 48 | 60 | 52 | 65 | 1103A-33TG2 | ≤211 | 3 | 3.3 | 105*127 |
GNRP73 | 52 | 65 | 58 | 73 | 1104A-44TG1 | ≤207 | 4 | 4.4 | 105*127 |
GNRP88 | 64 | 80 | 70 | 88 | 1104A-44TG2 | ≤213 | 4 | 4.4 | 105*127 |
GNRP103 | 75 | 94 | 82 | 103 | 1006TG1A | ≤210 | 6 | 5.99 | 100*127 |
GNRP150 | 110 | 138 | 120 | 150 | 1006TAG | ≤205 | 6 | 5.99 | 100*127 |
GNRP165 | 120 | 150 | 132 | 165 | 1006TAG2 | ≤205 | 6 | 5.99 | 100*127 |
GNRP225E | 165 | 206 | 180 | 225 | 1306C-E87TAG3 | ≤220 | 6 | 8.7 | 117*136 |
GNRP250E | 180 | 225 | 200 | 250 | 1306C-E87TAG4 | ≤219 | 6 | 8.7 | 117*136 |
GNRP259E | 188 | 235 | 207 | 259 | 1306C-E87TAG5 | ≤221 | 6 | 8.7 | 117*136 |
GNRP275E | 200 | 250 | 220 | 275 | 1306C-E87TAG6 | ≤223 | 6 | 8.7 | 117*136 |
GNRP344E | 250 | 313 | 275 | 344 | 2206C-E13TAG2 | ≤201 | 6 | 14.6 | 137*165 |
GNRP388E | 280 | 350 | 310 | 388 | 2206C-E13TAG2 | ≤198 | 6 | 14.6 | 137*165 |
GNRP450E | 320 | 400 | 360 | 450 | 2206C-E13TAG3 | ≤201 | 6 | 14.6 | 137*165 |
GNRP500E | 360 | 450 | 400 | 500 | 2506C-E15TAG1 | ≤216 | 6 | 15 | 137*171 |
GNRP550E | 400 | 500 | 440 | 550 | 2506C-E15TAG2 | ≤211 | 6 | 15 | 137*171 |
GNRP625E | 450 | 563 | 500 | 625 | 2806A-E18TAG1A | ≤196 | 6 | 18.13 | 145*183 |
GNRP700E | 508 | 635 | 560 | 700 | 2806A-E18TAG2 | ≤203 | 6 | 18.13 | 145*183 |
GNRP800 | 580 | 725 | 640 | 800 | 4006-23TAG2A | ≤199 | 6 | 22.921 | 160*190 |
GNRP900 | 640 | 800 | 720 | 900 | 4006-23TAG3A | ≤200 | 6 | 22.921 | 160*190 |
GNRP1000 | 720 | 900 | 800 | 1000 | 4008-TAG1A | ≤206 | 8 | 30.561 | 160*190 |
GNRP1125 | 818 | 1022 | 900 | 1125 | 4008-TAG2A | ≤208 | 8 | 30.561 | 160*190 |
GNRP1375 | 1000 | 1250 | 1100 | 1375 | 4012-46TWG2A | ≤212 | 12 | 45.482 | 160*190 |
Genset Features:
1. Genuine UK Perkins industrial diesel engine
2. Radiator 40°C max, fans are driven by belt, with safety guard
3. Genuine stamford. Leroy somer, marathonm, engga alternator
4. Choice of manual/auto and AMF control panels and protection systems
5. Digital auto-start panel
6. Anti Vibration Suspension Absorber
7. Dry type air filter, fuel filter, oil filter
8. 10-hour operation base tank
9.Mould case circuit breaker
10. 24V DC start motor and storage battery
11. 24V charge alternator
12. 24V batteries, rack and cable
13. Rippl;e flex echaust pipe, exhaust siphon, flange, and muffler
14. Comply with ISO and CE standards
15. All generator sets are gone through rigorous testing before beging released to the market place, including 50% load, 75% load, 100% load and all protection function(over speed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)
Engine Features:
1. Genuine UK industrial diesel engine
2. Multi-cylinder in-line or veer engine, 4-stroke, direct injection
3. Naturally aspirated, turbocharged, water cooled or turbocharged with air intercooler
4. Machinery or electronic governing
5. Fuel injection pump
6. Electric motor starting system
7. Forged steel crankshaft, cast iron cylinder and replaceable wet type cylinder liner
8. Low discharge, and low fuel consumption
9. Installed conveniently and maintain easily
Alternator Features:
1. World famous brand AC alternator: Leroy Somer, Stamford, Marathon, ENGGA
2. Brushless, 4 poles, rotation magnet
3. IP21-23(NEMA1) enclose is standard for all industrial alternators
4. H class insulation system
5. AVR self-regulated, voltage regulation rate: ≤±1%
6. Simple installation and maintenance with easy access to terminals, rotating diodes and coupling bolts
7. Wide range of flange adaptors and single bearing disc coupling
8. Radio interference restraining accords with the stipulation of VDE0875-N and ISO8528
9. Moisture proof, sand-proof, dustproof, salt-proof and vibration-proof
Digital Control panel
Controller Brand: Smartgen, Deepsea,ComAp
Control Panel: English interface,LED screen and touch buttons.
Main Functions:
1- Display loading power, voltage, currenct, frequency, speed, temperature, oil pressure, running time etc.
2- Warning when low or high voltage, low or high frequency, over current, over or low speed, low or over battery voltage etc.
3- Over load protection, over/under frequency protection, over/under/imbalance voltage protection, and low oil shutdown
Soundproof/Silent Box:
1. Excellent ventilation
2. Oil tank mounted on base frame for 12 Hours working
3. Highly Corrosion Resistant construction
4. Excellent Access for Maintenance
5. Security and Safety
6. 1m<80DBA / 7m<70DBA
Optional:
1. Trailer type
2. Soundproof / water proof
3. ATS (automatic transfer switch)
4. Parallel system
5. Remote system
PMC System:
1. Standard 23 pitch windings avoid excessive neutral current
2. Permanent magnet generator system provides constant excitation under all condition
3. Optional accessories available for easy paralleling with mains or other generators
4. AVR auto voltage regulation, auto exciter, auto adjustment
- Q: Is there any difference between motor and motor? A positive answer
- Electric motors include motors and generators. The general term for generators and motors is that they are conceptually different. However, certain motors, such as synchronous motors, are generally more used as generators, but can also be used directly as motors. Asynchronous motors are more used for motors, but by adding simple peripheral components, they can also be used as generators.
- Q: The advantage of the pole motor relative to the ordinary motor
- She points to the pole machine: Reasonable structure design flexible lead direction, the bonnet motor junction box can rotate and install itself Excellent protective grade of low noise, low vibration and high performance
- Q: If the speed of a normal motor is adjusted by the frequency converter, the speed can exceed the rated speed, and if the current power is above the rated speed, what is the change in current power
- When the torque is greater than the load, the frequency can reach the limit, higher than the constant power characteristic, and the real-time current is not overrated. The change of motor is just a consideration of the torque
- Q: What is the difference between a servo motor and a direct drive motor?
- Obvious distinction The direct drive motor is powered by the power supply, which is not controllable. The servo motor is driven by the actuator, which is controlled at speed, torque and position.
- Q: A 2.2 KW motor will require a lot of electricity a day
- First you have to determine whether the motor is working under the rated load at 2.2 KW, which is 24 hours a day Electricity is 2.2 * 24 = 52.8 degrees. Don't need to be multiplied by three.
- Q: How does the heat of dc motor control
- 70-90 ℃ belongs to the normal phenomenon, as long as less than 130 ℃, generally do not have what problem, if you really feel overheated, the drive current set the speed of the motor about 70% of the rated current or reduce one Some. When there is no failure, it is normally warm. Of course, the normal heat won't be too hot. Normal fever: One, the coil has the resistance, the current flows through the loss power; The magnetic field of the iron core has a "hysteresis loop". The iron core and the vortex, the magnetic energy that turns the electric energy into a part of the magnetic energy that becomes electric current and then becomes heat energy; There is friction between the mechanical rotating parts, and a part of the kinetic energy of the transition continues to change to heat energy.
- Q: The motor does not turn except sound
- The motor shaft and shaft sleeve clearance is too large, or motor rotor momentum is too big, a magnetic field when electric motor internal rotor and the stator attraction bruised (commonly known as "chamber"), unable to turn. At this point the electric current will soar, if not handled in time, the machine will burn down.
- Q: The difference between B34 and B35 motors
- Motor by using the power divided into dc motor and ac motor, electric power system in most of the motor is ac motor, can be synchronous motor or induction motor (motor stator magnetic speed and rotor rotating speed is not synchronized rate).
- Q: Is the servo motor more than the general motors? Why is that?
- Of course, it's not the same, if it's all running at full capacity, but if you have a surplus, the servo motor will be more efficient, after all, the response is fast
- Q: What is the difference between ordinary motor, step motor and servo?
- Step motor, rotor is permanent magnet type corresponding magnetic pole! Controlled in stator pulsed magnetic field can achieve precision step in! Apply to instrument and automatic control and drag! Less accurate than servo motor!
Send your message to us
3 Phase Perkins Genset Diesel Generator With 1606A-E93TAG5
- Loading Port:
- Guangzhou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 1500 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords