Quick Detail:

1. 15kva ,60kva 90kva 120kva Perkins diesel engine 

2. 230V/400V,3phase  Brushless, 4 poles

3. Smartgen digital control panel with ATS

4. Portabl,Silent Type Option 

 

 

Specifications:

 

Genset Model

Prime Power

Standby Power

Engine

Fuel Consumption

Cylinder No.

Displacement

Bore X Stroke

KW

KVA

KW

KVA

(g/kwh)

 (L )

(mm)

GNRP10

7

9

8

10

403D-11

≤252

3

1.131

77*81

GNRP15

10

13

12

15

403D-15

≤264

3

1.496

84*94

GNRP23

16

20

18

23

404D-22

≤243

4

2.216

84*100

GNRP33

24

30

26

33

1103A-33G

≤210

3

3.3

105*127

GNRP50

36

45

40

50

1103A-33TG1

≤212

3

3.3

105*127

GNRP65

48

60

52

65

1103A-33TG2

≤211

3

3.3

105*127

GNRP73

52

65

58

73

1104A-44TG1

≤207

4

4.4

105*127

GNRP88

64

80

70

88

1104A-44TG2

≤213

4

4.4

105*127

GNRP103

75

94

82

103

1006TG1A

≤210

6

5.99

100*127

GNRP150

110

138

120

150

1006TAG

≤205

6

5.99

100*127

GNRP165

120

150

132

165

1006TAG2

≤205

6

5.99

100*127

GNRP225E

165

206

180

225

1306C-E87TAG3

≤220

6

8.7

117*136

GNRP250E

180

225

200

250

1306C-E87TAG4

≤219

6

8.7

117*136

GNRP259E

188

235

207

259

1306C-E87TAG5

≤221

6

8.7

117*136

GNRP275E

200

250

220

275

1306C-E87TAG6

≤223

6

8.7

117*136

GNRP344E

250

313

275

344

2206C-E13TAG2

≤201

6

14.6

137*165

GNRP388E

280

350

310

388

2206C-E13TAG2

≤198

6

14.6

137*165

GNRP450E

320

400

360

450

2206C-E13TAG3

≤201

6

14.6

137*165

GNRP500E

360

450

400

500

2506C-E15TAG1

≤216

6

15

137*171

GNRP550E

400

500

440

550

2506C-E15TAG2

≤211

6

15

137*171

GNRP625E

450

563

500

625

2806A-E18TAG1A

≤196

6

18.13

145*183

GNRP700E

508

635

560

700

2806A-E18TAG2

≤203

6

18.13

145*183

GNRP800

580

725

640

800

4006-23TAG2A

≤199

6

22.921

160*190

GNRP900

640

800

720

900

4006-23TAG3A

≤200

6

22.921

160*190

GNRP1000

720

900

800

1000

4008-TAG1A

≤206

8

30.561

160*190

GNRP1125

818

1022

900

1125

4008-TAG2A

≤208

8

30.561

160*190

GNRP1375

1000

1250

1100

1375

4012-46TWG2A

≤212

12

45.482

160*190

  

 

  Genset Features:

1. Genuine UK industrial diesel engine

2. Radiator 40°C max, fans are driven by belt, with safety guard

3. Genuine stamford. Leroy somer, marathonm, engga alternator

4. Choice of manual/auto and AMF control panels and protection systems

5. Digital auto-start panel

6. Anti Vibration Suspension Absorber

7. Dry type air filter, fuel filter, oil filter

8. 10-hour operation base tank

9.Mould case circuit breaker

10. 24V DC start motor and storage battery

11. 24V charge alternator

12. 24V batteries, rack and cable

13. Rippl;e flex echaust pipe, exhaust siphon, flange, and muffler

14. Comply with ISO and CE standards

15. All generator sets are gone through rigorous testing before beging released to the market place, including 50% load, 75% load, 100% load and all protection function(over speed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)

 

Engine Features:

1. Genuine UK Perkins industrial diesel engine

2. Multi-cylinder in-line or veer engine, 4-stroke, direct injection

3. Naturally aspirated, turbocharged, water cooled or turbocharged with air intercooler

4. Machinery or electronic governing

5. Fuel injection pump

6. Electric motor starting system

7. Forged steel crankshaft, cast iron cylinder and replaceable wet type cylinder liner

8. Low discharge, and low fuel consumption

9. Installed conveniently and maintain easily

 

Alternator Features:

1. World famous brand AC alternator: Leroy Somer, Stamford, Marathon, ENGGA

2. Brushless, 4 poles, rotation magnet

3. IP21-23(NEMA1) enclose is standard for all industrial alternators

4. H class insulation system

5. AVR self-regulated, voltage regulation rate: ≤±1%

6. Simple installation and maintenance with easy access to terminals, rotating diodes and coupling bolts

7. Wide range of flange adaptors and single bearing disc coupling

8. Radio interference restraining accords with the stipulation of VDE0875-N and ISO8528

9. Moisture proof, sand-proof, dustproof, salt-proof and vibration-proof

 

Digital Control panel

Controller Brand: Smartgen, Deepsea,ComAp

Control Panel: English interface,LED screen and touch buttons.

Main Functions:

1- Display loading power, voltage, currenct, frequency, speed, temperature, oil pressure, running time etc.

2- Warning when low or high voltage, low or high frequency, over current, over or low speed, low or over battery voltage etc.

3- Over load protection, over/under frequency protection, over/under/imbalance voltage protection, and low oil shutdown

 

Soundproof/Silent Box:

1. Excellent ventilation

2. Oil tank mounted on base frame for 12 Hours working

3. Highly Corrosion Resistant construction

4. Excellent Access for Maintenance

5. Security and Safety

6. 1m<80DBA / 7m<70dba< span="">

 

Optional:

1. Trailer type

2. Soundproof / water proof

3. ATS (automatic transfer switch)

4. Parallel system

5. Remote system

 

PMC System:

1. Standard 23 pitch windings avoid excessive neutral current

2. Permanent magnet generator system provides constant excitation under all condition

3. Optional accessories available for easy paralleling with mains or other generators

4. AVR auto voltage regulation, auto exciter, auto adjustment

 

Perkins Engine Genset Diesel Generator , 7kw To 125kw House Generator

Perkins Engine Genset Diesel Generator , 7kw To 125kw House Generator

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:The ordinary motor is adjusted by the frequency converter
Motor frequency control of motor speed and load, control system, closed loop control, open loop control, independent motor), which has no books can be used for direct access to information, because of the complexity of the situation. The output of the motor is lower than the rated speed, and the output of the motor is the output of the fixed torque. If, in the closed-loop control in main motor dynamic adjustment target rotation speed and torque of the motor, under the condition of the motor can meet the maximum load power, if be uniform, drag the project target motor with the higher level or lower level of drag torque is the same, and the final output linear velocity is given priority to with the main motor to work machine, tend to be the same.
Q:What is a hydraulic motor
No hydraulic motor of this statement, first of all, the mean power as the driving force of mechanical, electrical and hydraulic two different drive mode, only the hydraulic pump and hydraulic motor, hydraulic pump is driven by motor, have a plenty of driven by hydraulic motor,
Q:If the value of the capacitor on a motor is smaller, it can also be installed in other motors
The capacitance is ageing and the work is unstable and soon expires.I hope my answer will help you.
Q:The difference between the frequency converter and the ordinary motor
Electromagnetic design 'for common asynchronous motors, the main considerations in redesigning are overload capacity, startup performance, efficiency, and power factor. And frequency conversion motor, because of the critical slip inverse ratio at power frequency, you can directly start when critical slip is close to 1, therefore, overload capacity and startup performance is not need to think too much, and to solve the key problem is how to improve the ability to adapt the motor of the non sine wave power. Here's how it works: Minimize stator and rotor resistance as much as possible. Reducing the stator resistance can reduce the copper consumption of the base wave to compensate for the increase in the copper consumption caused by higher harmonic waves." In order to suppress the high harmonics in the current, the inductance of the motor is needed. However, the main effect of the rotor slot leakage resistance is large, and the high frequency harmonic copper consumption increases. Therefore, the size of the leakage resistance of the motor should be adjusted to the rationality of the impedance matching within the entire speed limit. ; 3) the main magnetic circuit of frequency conversion motor generally designed to unsaturated state, one is to consider will deepen higher harmonic magnetic circuit saturation, 2 it is to consider at low frequency, in order to improve the output torque and appropriate to increase the output voltage of inverter.
Q:What is induction motor? What is the difference between ordinary motors?
Who are on the stator winding and rotor embedded inside aluminum ring call induction motor, namely ordinary motor, dc motor excitation induction, copper head inverter, form anyway, magnetic pole, the price is now with copper and steel prices, the price is also growing sharply
Q:The difference between capacitor motor and general motor
It is. Capacitor start motor, because of its running winding is, reverse phase winding set, so as long as the switch, and start running winding winding concatenated direction, can be convenient for motor inverse, along the direction of motion.
Q:What is the difference between a carbon brush motor and a regular motor. Which machine is better
Have carbon brush motor is generally dc motor, compared with the ordinary ac motor, the working principle, scope of application is different, have different application scope, there is no who good who bad, ac asynchronous motor has simple structure, the manufacturing cost and use cost are bottom
Q:The difference between B34 and B35 motors
Motor by using the power divided into dc motor and ac motor, electric power system in most of the motor is ac motor, can be synchronous motor or induction motor (motor stator magnetic speed and rotor rotating speed is not synchronized rate).
Q:Why is electric motors not rotating? Everything else is good.
Electric common failures and troubleshooting methods instrument display is normal, motor does not turn the cause of the problem: (1) brake the damage judgment (2) speed control to turn the damage judgment damage judgment, (4) (3) motor controller damaged troubleshooting: (1) remove the brake handle socket (normally open type brake handle). If the motor operates, the brake should be replaced. Turn the source 5V voltage to normal, check the signal voltage, turn the transfer, the signal voltage should be in 0.8 ~ 4.2 V from low to high. If the voltage is not changed and is less than 1V, then the fault or turn will be short-circuited. If the voltage is greater than 1V and the change is normal, the signal (yellow, green and blue) is detected. If the voltage of the three-phase hall signal line is 5V and is in good contact, the motor hall is damaged and the motor or motor hall elements should be replaced.
Q:What is the difference between special motors and ordinary motors?
The generator is the same as the electric motor, which runs on the motor. The drive is driven by the rotor, and the magnetic field cutting stator winding inducs the electromotive force to become a generator.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range