Low Voltage Diaphragm Pump

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Specifications:

Perfect for caravans, boats, motorbikes, trucks and camping. Use it with fresh or salt water with your deck wash or to run your toilet or shower. These pumps automatically turn themselves on and off when you turn the tap on and off. Comes with filter and fittings. These pump are for intermittent use only.


A great pump for those country folk, with a small family, on tank water who only need to boost the pressure from a tank next to the house.


We have tested these pumps and found they will operate to a 2 metre suction lift and 5 metre head with no problems.


1.Maximum torque and operating efficiency/higher operating pressure and/or lower amperage than competitive pumps


2.Long life, no leaks, strong corrosion resistant


3.12/24 VDC and 115/220 VAC motors standard (consult factory for other voltages)


4.Quality components for extreme performance


5.Numerous fitting options for greater mounting flexibility


6.Voltage:12V/24V DC Diaphragm Pump,115V/230V AC Diaphragm pump


7. Expecially suitable for marine and recreation vehicle, such as boat and ship.Also suitable for Agriculture sprayer

 

Features

  • Lightweight and made from non corroding materials

  • Self priming

  • Run dry Protection

  • Easy to install

  • No maintenance

  • Simple to operate

  • Low power consumption

  • 12 months warranty

  • Automatically turns on and off

  • Comes with filter and fittings

How a Pump Works

The pump is driven by an AC or DC motor

In front of the motor is a valve assembly containing two to five valve pump chambers. Each valve chamber has a diaphragm behind it in the lower pump housing. As the motor shaft turns, an internal cam positioned behind the diaphragms causes the diaphragms to be pushed forward, then back in a continuous sequence creating a suction. As this suction builds, fluid is pulled hrough the inlet, through the various valve chamber check valves to the outlet he volume of flow is determined by several factors including: the number and size of the pump chambers,cam offset, operating pressure, fluid viscosity.


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:The working principle of magnetic pump
Control of cooling fluid flowThe pump is running, you must use a small amount of liquid in the magnetic separation between the rotor and the casing annulus area and sliding friction bearings for flushing cooling. The cooling liquid flow pump design flow is usually 2%-3%, the annular area between the magnetic rotor and sleeve of eddy current generated because of high heat. When the cooling and lubrication the liquid is not enough or poor flushing holes to plug, will result in permanent magnet medium temperature is higher than the operating temperature of the inner magnetic rotor gradually loses magnetism, the magnetic actuator failure. When the medium is water or water-based liquid, can make the annulus area temperature maintained at 3-5 DEG C; when the medium or hydrocarbon oil that can make the annulus area temperature maintained at 5-8 degrees.
Q:What does "dual purpose" of water pump mean? Please expert advice
In order to ensure safe and continuous operation, three pumps usually need two units and run one standby.Precautions for using pumps1, if there is any small water pump failure, remember not to work. If the pump shaft packing end wear should be added in time, if you continue to use the water pump will leak. The direct effect of this is the increased energy consumption of the motor, which will damage the impeller.
Q:Must the water pump in the tank be all soaked in water?
Usually you have to soak it all in the water. If you don't want to put it in the water, you can buy an amphibious pump. At most, you can expose it
Q:What are the application areas of pumps?
1, urban water supply 2, sewage system 3, civil and construction systems 4, agricultural water conservancy system 5, power station system6. Chemical system 7, petroleum industry system 8, mine metallurgy system 9, light industry system 10, ship system
Q:The suction pump has a nominal suction range of 30 metersHow deep can a well be sucked?Well, sixteen meters,
A standard atmospheric pressure can be 10.33 meters to 30 meters of water, suction is atmospheric pressure there are three standard atmospheric pressure so high? This is impossible in general, remove the vaporization removed 0.5 meters critical yo,
Q:Pump operator's responsibility Sharing the rules, responsibilities, etc..
3. master the operating rules of the pump operation, and make sure the pump position is reasonably determined. Do a good job of site investigation, find out, pay attention to.4. master the working principle and basic technical parameters of the delivery pump. Obey the command of production dispatcher to ensure the completion of production tasks.5., according to the number of tanker at the scene, determine the pumping speed, in order to ensure the continuity of pouring.6. normal pumping, the discharge rate should be uniform, to prevent uneven discharge, resulting in pressure pipe gas plug, and thus lead to pipe or pipe explosion accident.
Q:What are the problems that should be paid attention to when using vacuum pumps?
(1) check the vacuum pump line and the joint site regularly to see if there is any looseness. Turn the vacuum pump by hand and see if the vacuum pump is flexible.(2) add lubricating oil to the bearing body, observe the oil level at the center line of the oil mark, and the lubricant shall be replaced or supplemented in time.(3) plug screw vacuum pump of the water screw, filling water (or lead paste). (4) turn off the gate valve of the water outlet pipe and the outlet pressure gauge and the vacuum gauge. (5) point motor, and see if motor steering is correct.(6) start the motor. When the vacuum pump is in normal operation, open the outlet pressure gauge and the inlet vacuum pump. As soon as the proper pressure is shown, the gate valve is gradually opened, and the motor load is checked.
Q:What is a gear pump for?
Internal wear of oil pumpOil pump parts wear will cause leakage. The large leakage area between the floating axle sleeve and the end face of the gear is the main part of the inner leakage. This part of the leakage accounted for about 50%~70% of the total leakage. The pump efficiency of the gear pump is much lower than the input power when the gear pump is worn and leaked. All of its losses are converted to heat energy, which will lead to overheating of the oil pump. If the joint plane is pressed, the movement of the floating axle sleeve will cause a little wear and tear when the work is in use, so that the farm tools can be lifted slowly or can not be improved, so the floating axle sleeves must be replaced or repaired.
Q:The difference between submersible pumps and centrifugal pumpsWhat's the difference between the two? What is applicable and what?
High speed rotating impeller blade drives the liquid to rotate, and the liquid is thrown out so as to achieve the purpose of conveying. There are many medium for transportation, such as oil, water, chemicals and so on. The pump shaft and the motor shaft are of the same shaft, the pump and the motor are made into an integral body and immersed in water. The medium of transportation is water.
Q:Rules for operation of centrifugal pumps
Working principle and process flowWorking principle: when the drive motor with high-speed rotating impeller, full of fluid in the pump body under the action of centrifugal force, was thrown from the impeller center to the outer edge of the impeller, in this process, the fluid energy, improve the pressure can, at the same time also increases the energy flow rate increase. The liquid from entering the pump impeller shell, the liquid flow gradually widened, the liquid velocity decreased gradually, which will be part of the kinetic energy into pressure energy, which further improves the static pressure of liquid, and liquid with high pressure in pressure pipeline. When the liquid from the leaves out when the impeller center creates pressure and low pressure than the out plane is big, under pressure drive, liquid is continuously from the center of the impeller suction, with the pressure of continuous discharge.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range