Product Description:

This series of products in the design, production and testing, etc. mainly follow the bellowing latest version standards and specifications:
GB6245-1998 “performance requirement and test measure of fire fighting pump”
GB/T3214-91 “test measure of capacity for water pump”
GB/T3216-2005 “rotor dynamic pumps-hydraulic performance acceptance tests-grades 1 and 2
JB/T443-92 “technical conditions for centrifugal long shaft pump”
JB/T3564-92 “types and basic parameters of deep well long shaft pump”
JB/T3565-92 “centrifugal pump efficiency”
JB/T3565-92“centrifugal pump efficiency”

The technical parameter of type APIS pump
Pump outlet diameter:150~1000mm
Capacity:60~8400m³/h
Head:12~180m

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:The distance from the pump button to the ground
After confirming that the fire pump has started running, issue a command signal to the hydrant button to light the green answer light.
Q:Direct connection pump What is straight pump and non direct pump? What's the difference in structure?
Direct connected pump: pump impeller installed directly on the motor shaft, it looks like a whole, relatively compact, simple installation, but the general power is relatively small (big bad processing connection, but not absolute);Non direct pump: pumps and motors are independent of each other, through the coupling torque transmission, the structure is relatively large, complex installation, to adjust the level / concentricity and so on, the general power is relatively large
Q:How is the pump level of submersible sewage pump determined?
Generally as:The bottom elevation of sump sump plus 300 is the water level of pump stopThe top 300 of the sump top elevation is the pump water level
Q:How to select the fire pump?
Modify the part: (the design of regional common fire pump should be in accordance with the requirements of the original design, building design) contains a 55m high building, and the basement is about 6m, the pump reached in the basement height about 61m (common fire pump should be based on the highest floor of other low floor area, low ring and take in this case, relief measures) 61 levels, the most unfavorable hydrant to reach 0.07MPa (maximum allowable 0.5MPa) plus loss of lift at least about 90m more appropriate, of course can be higher to take relief measures (120 too high), the basic flow of lossless (with the same time there is only one building fire) according to the maximum amount of a building fire water pump set can be, there must be a backup with a preparation, and then select the appropriate pump manufacturer specification query.(the 20 houses on 99m are only shared with a 135m pump)
Q:What's the difference between a centrifugal pump and a centrifugal pump? What are they used for?
Centrifuges are generally used to classify liquids of different densities in liquids.
Q:Why does the centrifugal pump close the pressure to start?
Therefore, the operation rules of multistage centrifugal pumps require that the inlet valve be opened before opening, and the outlet valve is closed. However, the export valve closed time can not be too long, because at this time the medium in the pump cycle, the medium temperature gradually increased, easy to cause mechanical seals, due to lack of lubrication friction and wear or damage.
Q:Fire control center manual start fire pump directly, multi line control
The vertical line NHKVV-7*1.5 is the remote starting line of fire controller to fire pump room.
Q:How to calculate the motor power of metering pump?
Two Hydraulic power, metering pump rated flow (L/H) X, maximum pressure (Barg) / 36000 = kw
Q:Pump unloading in hydraulic transmission,
Can be used for short-term shutdown, pump non-stopNo unloading, usually through the overflow valve back to the tank, high pressure, power, at this time insurable pressure, and so on
Q:Why should I pump the pump before starting the centrifugal pump?
Before the operation of the centrifugal pump, the pump must be filled with water, exhaust the air, before you start the operation. All centrifugal pumps should be handled this way, which is the centrifugal pump itself.The way of water diversion:1., in the centrifugal pump outlet increase water diversion pump (usually using vacuum pump), start the centrifugal pump before, start the vacuum pump, the centrifugal pump air into;2. increase the vacuum water tank before the intake of the centrifugal pump to meet the working conditions of the centrifugal pump;3. in the centrifugal pump inlet water increase valve, to meet the working conditions of centrifugal pump;4., if the water tank or water tank volume of water level is higher than the centrifugal pump position, the first operation of the front row empty, usually do not empty, you can use.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range