• Full Welded Forged Steel Ball Valve DN 24 inch System 1
  • Full Welded Forged Steel Ball Valve DN 24 inch System 2
  • Full Welded Forged Steel Ball Valve DN 24 inch System 3
  • Full Welded Forged Steel Ball Valve DN 24 inch System 4
Full Welded Forged Steel Ball Valve DN 24 inch

Full Welded Forged Steel Ball Valve DN 24 inch

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
10 pc
Supply Capability:
100 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Design Features of full welded forged steel ball valve

The body of ball valve is full welded,selects high quality forged material,and adopts the advanced forged forming technology to form two semi-spheres which are welded into a whole in the middle of the body.This welding technology differentiates the ball valve form others,and makes the valve more spherically,so the valve structure is more compacter,lighter and stronger.Besides,the middle direct welding realize highly accurate valve body manufacturing,makes fully and completely sealing between the seat and ball.The full welding instead of bolts completely avoids the outside leakage,so ball valve is the ideal product for under-ground,offshore working platform and under-sea equipments.

Adopting fixed plates or trunnion to support the ball

The top and bottom of the ball is supported by upper and lower fixed plates or stem and trunnion,and the ball is accurately placed in the center of the ball valve to achieve complete seals and precise movements.When plate adopted,the force exerted by the medium to the ball is distributed via the plate to the left and right bodies,so that the stem does not bear the blending moment from the medium,but only the torque from the ball rotation during the opening/closing of the valve.The low-friction PTFE Teflon composite bearings installed between the ball axis and fixed plate and between the stem and the trunnion can absorb ball moving action caused by the pressure of the medium.This structure brings stable actions and easy operations for the ball valves,and the required operation torque can be reduced,so smaller actuators can be used,and the cost is cut down.

ball valve seat is floating structure,means the seat can move along the medium direction,so that the seat can fit against the ball all the time.
Double piston effect structure seat of full welded forged steel ball valve
Seat design is special double pistons effect structure,it can ensure the seal wherever the medium flows into the ball valve.

Seat multistage seal strucute of full welded forged steel ball valve
As following graphic instruction,on seat bearing ring,set two soft sealing rings(A and B)and metal sealing spherical surface which can seal with the ball.Seat ring A is spring loaded,which seals the surface with the ball tightly to the surface to form an initial seat;When there is pressure generated from medium,the piston force is generated to make seal ring A elastically deformed and seal ring B fit the surface of the ball surface due to the piston effect caused by area difference,thus the second seal forms.When the medium pressure is rising.It will generate huge pressure to seal ring A and seal ring B,so the two seals have a greater elastic deformation,then metal seal ball surface compact with ball surface to form the third level of metal to metal seal.

Secondary seat seal device of full welded forged steel ball valve
As the above graphic instruction,the secondary seal device(seat grease injection valve)can be chosen according to the actual working condition,medium requirement,seal requirement,etc.Seat ring grease injection valve is a one-way valve,installed on the body,which can prevent the leakage and inject grease under the outside force.When secondary seal is required,there is a grease injecting channel and hole on the seat ring.The grease can form a seal between the seat and the ball,and then stop the leakage.

Standards Applied of full welded forged steel ball valve

Design   Standard

 API   6D customize 

Connection   Standard

 ASME   B 16.25-2007  ASME B 16.5  ASME B 31.4  ASME B   31.8  DIN  GBGB/T  JBJB/T JIS customize   

Test   Standard

 API   6D customize 

Face   to Face

 API   6D customize 

Pressure-teperature   rating

 ASME   B 16.34-2004 customize 

Marking

 MSS   SP-25 customize 

FAQ of full welded forged steel ball valve:

Q1:I can’t find the type of steel check valve which I need. what can I do?

The chart above only lists out some common composition of steel check valve parts.We may provide other different parts material composition according to the customer's request or the actual valve working condition.

 

Q2:Which certification do your products pass?

  Our products are in accordance with ISO 9001ISO 14001API 6AAPI 6DTS CEAPI607/6FA/BS6755.

 

Q3:How can I place an order?

  The only one thing you should do is to tell us the sepecification about type quantity and  mode of transportation, then we will send you quotation within 24 hours.



Q:List words that rhyme with valve...I need these.
salve, like to put on a wound or something
Q:i wanna know the role of TOP ENTRY in this definition it's difference with side entry valve.
Top entry ball valve: One piece body construction, Fire Safe, Full / Reduced Port, Soft or Metal Seated, Antistatic device, Blowout proof stem, Lever operated, Gear Operated or Actuated. Made up of Carbon Steel, Stainless Steel, Low Temp Carbon Steel, Duplex, Super Duplex, Super Austenitic Stainless Steel and exotics like Inconel, Monel, Hastelloy etc.
Q:Can anyone tell me what to do if i know that I have the type of valve stem that was recalled TR413chrome?? Will they replace them for free since they are a recall or do I have to dish out some more $$ to fix the problem??? The company that sold them to me is in Florida (Wheelmax) and I am in Mass. Not sure what to do to avoid having to pay out more $$ to have them replaced...any help is greatly appreciated
I'd have to say they will probably supply you with the new valve stems for free, but you may have to pay to have them installed (unless you know how to do it yourself.) We had a fuel pump recall and they sent us a new one but we had to install it ourselves. Good luck!
Q:My pressure reducing valve (or restricting valve) was looked at by three master plumbers and they all said I need a new one. My water pressure has been low for weeks. It measures about 100 psi at the outside hose bibs, but it is very low inside and suddenly reduces after you turn on the facets inside. The shower is ok. My automatic sprinkler system is not able to work now due to low pressure. A relative of mine thinks we can just add a handle (as one is missing) on the valve and adjust the pressure ourselves. The repair of the valve is around $500-600! I am told in Texas that we have to have a permit and inspection to repair this valve. Also I was told by the last plumber that came out, that I have to install a expansion tank on my new hot water heater according to code. I'm not sure if that is a city code or federal. Please respond as to information you may have on this problem. The expansion tank is required I'm told when you have a pressure reducing valve for safety, is this true?
The cost you quoted seems a bit high to me. Mine didn't cost anywhere near that amount in East Texas. A pressure reducing valve acts like a check valve when there is no flow. That is it closes as the pressure rises when you are not using any water. In this condition, the hot water heater can raise the pressure even higher since there is no place for the expanding water to go. That is the reason for the expansion tank. Without the expansion tank the pressure relief valve on the hot water heater can relieve unnecessarily or weep a bit.
Q:I think on old AC units They had a different valve than the shrader. It might be called a king? Anyway, I can't get my gauge to read the pressure. The needles don't move at all. How can I measure, refill this type of HVAC?
Unless you are EPA certified, you have no business checking the refrigerant in old AC units. If you get caught, you could face a hefty fine.
Q:Our water heater (bought in 2007 so still fairly new still under warranty luckily) seems to release water from the pressure release valve quite frequently. Everyone seems to say that it shouldn't do it often and ours probably does it a couple times per day. 2 main questions - 1. Is there really a risk of too much pressure building up and the water heater exploding (that's what the sales guy at Lowe's said) and 2. Any idea what the problem might be/what we should check out?
Theres no risk of the water heater blowing up if the relief valve is doing what is supposed to.But i recommend a professional check out the installation.Do you know if you have an expansion tank installed on the cold water side? We put one in on every water heater installation.A professional will also check system pressure-some houses have a Pressure Reducing Valve (PRV) and they can fail.You need to check static and dynamic pressure both.And finally sometimes relief valves fail too.If you dont know how to check these things,call a professional.
Q:A diabetic patient undergone CABG having aortic valve problem.Cardiologist suggested valve replacement
Can be cured by valve replacement... alternatively, if you can't/won't go through open heart surgery then you may be able to get valvuloplasty. A balloon is used to stretch the valve open. This does not last nearly as long as replacement, but avoids surgery. A third alternative would be to contact one of the percutaneous valve REPLACEMENT centers (Mayo, Cleveland Clinic, Columbia). This is an experimental procedure which replaces the valve using catheters instead of surgery. Advice offered here is not meant to be a replacement for proper evaluation and examination by a qualified medical professional and should not be construed as such.
Q:Also what prevents this from occuring? I have a lab due tomorrow for my biology class this is one of the questions. the answer is no where in my book, and we haven't discussed this in class. im also having a hard time finding the answer online. i would assume it would have something to do with the elasticity of the valves, and i know that when valves are weak sometimes blood can flow back into the artium when the ventricle contracts causing a heart murmur and other problems, but i haven't came across any information that talks about the valve being pushed backwards. if you can help me out that would be awesome! thanks =]
the heart valves maintain the unidirectional flow of blood in the heart by opening and closing depending on the difference in pressure on each side. (wiki) So I would assume that the pressure of blood flow is what prevents the valve from pushing backwards. ALSO Atrioventricular valves These are small valves that prevent backflow from the ventricles into the atrium during systole. They are anchored to the wall of the ventricle by chordae tendineae, which prevent the valve from inverting. The chordae tendineae are attached to papillary muscles that cause tension to better hold the valve. Together, the papillary muscles and the chordae tendineae are known as the subvalvular apparatus. The function of the subvalvular apparatus is to keep the valves from prolapsing into the atria when they close. The subvalvular apparatus have no effect on the opening and closure of the valves, however. This is caused entirely by the pressure gradient across the valve.
Q:I had heart surgery a little over a year ago. This surgery gave me an artificial aortic valve in replacement to my real aortic valve. Before this I smoked weed all the time, but now, I 'm on blood thinners, and I'm not sure if it's okay. Is it?
Are you crazy, do you want to move in early at a cemetery? The reason for that bad valve could be your frequent encounter smoking ganja. Ganja has numerous amounts of varied chemicals, and the soot your bronchioles clogged with can cause less oxygenated blood to be dispensed by the heart thus plaques have form and a valve was damaged. It was all about the ganja smoking you did, then YOU WANT TO GO BACK AND COMPLETELY KILL YOURSELF AFTER A GRUELLING SURGERY WHERE DOCTORS GAVE YOU A NEW VALVE. BROTHER YOU DO NOT LOVE YOURSELF, AND SHOULD NOT COME ON YAHOO ANSWER FOR OPINIONS. SO IF YOU GOT SOMEONE SAYS YES, YOU WOULD SMOKE MORE POT. PERHAPS YOU SHOULD SEE A PSYCHIATRIST AND NOT A CARDIOLOGIST, AS YOU ARE ASKING A STUPID QUESTION.
Q:We had a sprinkler zone that did not send much water to sprinkler heads. Checked the spring on the solenoid. We took off the top of the valve and rinsed gasket and parts below – put back together. The zone then worked. However I then noticed that the valve that does not shut off completely – water meter shows usage. I turn off water as it comes from the house.We then replaced the solenoid, the zone would not turn on. When back to the old solenoid. I switched wires at the timer and valve, it started, but when the cycle was through there still was water going through the system. Put wires back to their original locations.Space is crowded and looks tricky to replace valve. Would like advice on that for next year. However my main concern is when we shut down for the winter. We manually run each of the 8 stations and blow out the water. Will the bad valve cause a problem?
You didn't mention who manufactured the valve. Sounds like you have a small stone caught between the valve body and the diaphragm. Diaphragms don't open that much and a large enough piece of debris can get caught. Also some valves are manufactured with a small tick screen that is inserted into the diaphragm itself. If it comes out then there will be a small hole in the diaphragm, causing leakage. Take the entire top off of the valve body and inspect the diaphragm. Be careful of the spring in the top. If it was a stone, you will see an indentation in the diaphragm. Feel around the seating edge to see if it is damaged. If all is OK, just put it back together, if not, take the diaphragm to a sprinkler place and get a new one.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords