1. Product Introduction:

ZX series self-priming centrifugal pump falls into the category of self-priming centrifugal pump,which has such advantages as compact structure, easy operation, stable running, easy maintenance, high efficiency, long life and strong self-priming capacity. The bottom valve needn't be mounte in the pipeline. It 's only necessary to reserve a fixed quantity of guide liquid in the pump body before work. Therefore, it simplifies the pipeline system and also improves the labor conditions

2. Range of Application:

1) It is applicable for city environmental protection, building, fire control,chemical engeering,pharmacy,dyestuff,printing and dyeing, brewage, electricity, electroplating, paper making ,petroleum, mine, equipment cooling, tanker discharging,etc.

2) It is applicable for clear water, seawater, liquid containing acid or alkali chemical medium, and generally pasty slurry (medium viscosity≤100cP and solid content less than 30%).

3) When it's mouted with an arm sprayer, it can jet the water into the air to disperse into little raindrops for spraying , so it is a good tool for farm, nursery, orchar and tea garden.

4) It can work with any types and specifications of filter press, so it is an ideal type to deliver the slurry to the filter for the filter pressing.

3. Type Designation:

50 ZX 12.5-50 PB

50 Suction inlet diameter(mm)

ZX Self-priming pump

12.5 Rated flow (m3/h)

50 Lift head (m)

P Stainless steel

B Explosion-proof

4. Technology Parameters:

Flow3-280m3/h

Head12-80m

Power1.5-90kw

Ratary speed14502900r/min

32-200mm

Medium Temperature≤80

Self-priming high3.5-4.5m.

5. FAQ

1). Can I get trained on CNBM products?

Yes, we provide training courses in our factory (products, general and specific pump technology, hydraulics, and practical applications). Please consult your sales manager or get in touch with our headquarters for more information.

2). Are your pumps cheaper than those of your competitors?

CNBM aims to give its customers the highest standards of quality and service and delivery times, all at a reasonable price.

3). How long is your warranty?

Unless otherwise expressly authorized in writing, by specifying a longer period or different conditions, CNBM states that, for a period of twelve (12) months from delivery date, all Products supplied are free from defects in materials and workmanship, and conform to the applicable specifications. Either the delivery documentation or the invoice must be provided to prove delivery date. In absence of such documents, the production date appearing on the product label may suffice

FB Self-priming Horizontal Water Centrifugal Pump

FB Self-priming Horizontal Water Centrifugal Pump




Q:How many concrete pump tube diameter
The pump is generally divided into 125 and 150 two, the inner diameter is 125mm and 150mm. And the two kinds of each have high and low pressure points. Low pressure type type 125 pump for the pipeline diameter is phi 133,
Q:What is the distance between the pump and the wall?
What do you mean by that? If your pump is parallel to the wall! Then, the wall of the pump near the wall is usually 500mm. This is an empirical data, considering the import pipe length, pump maintenance and motor heat dissipation and other aspects of the situation to determine. Dozens of pumps installed in our company are placed in this size! Hope to be of help to you.
Q:Why does the centrifugal pump close the pressure to start?
The flow is zero (i.e. off dead) minimum, the highest lift power; with the outlet valve opening increases, flow increases, the lift, power and efficiency are increased, the maximum value (usually in the vicinity of the highest rated flow point)
Q:How many pumps does the 80cm tank use?
For example, you are 80 cm tank, assuming you are 40 cm wide, the water surface is also 40 cm, then the final count by 80X40X40=128000 cubic centimeter, that is, 128000 ml.
Q:What is the function of the heating pump system for the water pump design?
Will cause some of the internal friction gap disappeared, the coupling center damage. In this case, starting the pump inevitably results in vibration, friction, etc.
Q:No negative pressure water supply equipment, both the main pump and auxiliary pump, power is not the same, how to choose the control cabinet?
Non negative pressure water supply equipment can be divided into non negative pressure tank and box type non negative pressure compensation device, steady flow tank type non negative pressure water supply equipment is the negative pressure tank, pressure tank can eliminate the negative effect of network equipment, is equipped with a vacuum suppressor and water protection box; non negative pressure water supply equipment has the advantages of simple device is a water tank with the boost voltage stabilizing device of complex box at the same time with no negative pressure tank.The tank type non negative pressure water supply equipment adopts vertical multistage centrifugal pump. This kind of pump is low noise and high efficiency. Such as CDL series and imported CR seriesOrdinary box type non negative pressure water supply equipment can use multi-stage centrifugal pump, also can use stainless steel submersible pump, submersible pump costs will be lower, but the maintenance costs will be high.
Q:Types and differences of pumps
(I) volumetric typeClassification reciprocating rotary typeThe basic principle of reciprocating action by the piston in the cylinder in the cylinder volume changes again, with the suction and discharge of fluid in the shell or the rotor rotating member rotates, the volume of work between rotor and casing changes to the suction and discharge fluid, such as piston pump gear pump, screw pump(two) blade type;The main structure of vane pumps and fans is rotary, bladed impellers and stationary housings that rotate fluid through the impeller to do work, thereby enabling fluids to obtain energy
Q:Metering pumps related matters
2) change the metering pump diaphragmTrouble is often encountered when the old diaphragm is removed. Provide some additional advice on how to remove the old diaphragm.After in the pump head loose, remove the pump head before the stroke length adjustment to the 10% position. To ensure that the electromagnetic axis has sufficient pressure to maintain its connection firmly, so that you can unscrew the diaphragm.The pull end torque from the Jack out of the screw. Seize the liquid counter clockwise rotation. There is a slight resistance that can unscrew the diaphragm.Chemical 3 measurement may end in fluid crystallization, resulting in a one-way valve ball and seat valve does not work.In the end inhalation metering pump may have a gas leak. Hydraulic end suction side connector may lack O ring or suction valve connection loose.3) flow monitoring and measurement of a high viscosity medium, in the process of liquid delivery received a flow failure signal, how can we solve this problem?Move the hydraulic end by loosening the 4 pump head screws. Rotating stroke length to 10%, and seize the hydraulic end, and then slide out of the screw hole, then the screws do not touch them, but still control the back and diaphragm. Then rotate the component counter clockwise, with a slight resistance, and the diaphragm will loosen from the electromagnetic axis. If the diaphragm is not loose, use some grease on the contact surfaces of the diaphragm and the electromagnetic shaft. After a few minutes, gently tap the diaphragm with a small plastic hammer. Then proceed again in accordance with the above description.
Q:Do you have a suction pump higher than 9 meters?
This screw self-priming pump suction process can be more than ten meters or more, my family is using this
Q:How to distinguish the flow and displacement in the hydraulic pump? What's the difference between the two?
For example, once you sprinkle water from the tank to the ground, one shot of water is 1000 milliliters, which is equivalent to displacement, once (pump turn) 1000 ml.,

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords