Specifications
open type dioesel generator with yuchai enginee
1) Factory direct sale
(2) CE, ISO9001 quality
Power range | 18-650KW |
Engine | All series powered by Yuchai engine |
Alternator | All series owning alternator options of Stamford/Marathon/ENGGA |
Controller system | Hanging control box, automatic control module Smartgen HGM6310 |
Base frame | International channel steel welded base, inbuilt composite damping system; sandblast, acid-washing, antiseptic treatment |
Radiator | Standard genset-joining radiator of 40 °C ambient temperature |
Diesel generator Powered by Yuchai Engine,which yuchai is a large state-owned enterprise and a Nasdaq listed company in USA (NYSE:CYD). Its main business covers diesel engine, contruction machinery, vehicle parts. The engines produced by Yuchai include series YC6G, YC4G, YC4E to which American technology applied, series YC6A, YC6B, YC6J, YC4B, YC4D, YC4F, YC4W to which German technology applied, and YC6M series in which world top technology integrated, totally 12 series.
YUCHAI Series | Power(KW) | Power(KVA) | Jichai Engine Model | Cylinder NO. | Fuel consumption g/kw.h | DimensionL*W*H | Weight KG |
FKS-Y800 | 800 | 200 | YC6G245L-D20 | 6 | ≤195 | 2500*970*1500 | 2300 |
- Q: Does a current carrying conductor experiences a force onlywhen the current is in the same direction as the magnetic field?
- Current carrying conductor will always experience force, weather the magnetic field is from external or self induced magnetic field. The reason I know this is because I have been involved in testing 50,000 watt diesel generator sets by applying a dead short (1000's amps) across the output. And have observed double (00) cables jumping on the laboratory floor (like a garden hose when you slam the valve shut).
- Q: Any help regarding my question would be greatly appreciated.I have a 1991 Prevost Marathon Mirage LE Luxury Motorcoach and I am wanting to remove the Engine (Detroit 8v92) is this a job to hard for a reasonably experienced Diesel mechanic to conquer? I have all the space in the world in my game room to do this. Just wanting to know if the engine is on a slide track and it slides out (I have seen other coaches do this) or do i have to totally unmount the engine to get it out to where I can work on it? I know this is a stupid question and I don't know exactly how to word it. But any help regarding my question again would be greatly appreciated.any diesel mechanics out there? Is there a video posted somewhere on the web that may show a backyard mechanic doing this so it may enlighten me. lol
- Sir, Engine Dismantling Very Responsible Job Once Removed The Parts You Should Reassemble That Is - The Problem.Total Repairs Anybody Will Do But Once Removed By You Nobody Give Attention Keep in Mind. Firstly Remove The Battery Store It Safe Location.Disconnect The ,Diesel lines,Wirings,Cables,- Sesors, Modules, Then Disconnect,Gear BellHousing,Torque Coverter If There,Engine Mountigs, All Water Lines,A/c Connections,Front Grill,If You Need The Bonnet Also, Put The Rope Put Cross Bar- Tie Properly Care The Mudguards,Pull The Engine With Sufficiant Manpower Or Crane Nor Lifter. Check Once More before Takeout The Engine Assy-Wheel Blocks,Support To The Gear Box,Door Lock, Safe The Key,Nobody Not Allowed Inside The Car, Before Pullout Check Again And Make Sure Nomore- COnnections Arrange The Table Keep Everythings Ready Pullout Keep On The Table Check Externals. Make More Dismantling The Engie Take To Machine Shop They Knows What Nee for Your Engine. If Over machine Work Bring To Spot Selct New Parts What You Need Do Accordingly.
- Q: believe the mh didnt come with a seperate 12v power supply to run items after the mh engine is stopped! I want to run these items seperately from the mh engine 12v system if possible. The mh has its own stock inverter but i am unable to locate a pwer supply other than the 12v battery in the engine compartment which is used for the primary engine power supply. Does this sound right. For instance are their electrical systems that rely solely on the main or engine battery power supply(without a secondary seperate accesories battery or power supply) and are totally reliant on charging only from the engine charging system. I do have a 2500 watt external generator but i am limited on the hours of usage. Mainly i am interested in running the light ,tv and vcr without assistance of my external generator. How the hell do i set this all up??
- what you basically need is a motor home generator for that one,i own an older one that did not come with a generator,and we addd one to it,plus we also added a 24 volt power system to power it with and an inverter,you can run the the lights for about 6-8 hours on the inverter system but when using the generator to keep the 24 volt batttreies charged you can literally run it all night long ,we put this one though a test to see how long it would run for and it never died out,first you have to increase the battery box size to hold two more batteries then you run all this through a switch that changes it from generator power to battery power,i got mine as a kit throug rv,s of america,they sell a complete kit for doing this,it took days to get this on and get it working right,but now i have a switch up front by the driver area that you throw that switches it to generator and then you use the invertor that came with the kit to run the tv vcr microwave,and just about all the lights are now on 12 volt dc,i got 3 batteries one for the main part of the rv and the other two power the invertor,its not hard to do they send complete insructions with the kit,its calle an update kit and works on all older model rv,s.it cost around 900 bucks though but it remidies the problesm of not having power,when i first looked at all the stuff it came with i freaked out,i thought there was no way i would get it to work,but we did,you dont get the generator with the kit though,that you have to buy seprately,you get the hook ups for it though,and you get a choice of getting gas or a diesel generator now,when i bought mine all i could get was a gas one,check their web site out on this ,go to the accessory part when you click on it it goes to power,you can sullpy your own generator though and it still works right,they just like to sell you a generator if they can,good luck with it.
- Q: HI, I'm a college student Marine EngineeringI don't know the procedures of*pre-start up*start-up*stoppingof an emergency AC Generatorplz. help :)I'm going to monitor during operation that's why I want to know all of thatplease response as soon as possible.
- Before check all fluid levels and turn off all breakers before starting or stopping!
- Q: I inherited a never used generator from a family estate with no motor. After a tornado here last fall I've decided to build a gen-set with it and I have a few questions. 1) Does the 1800 rpm generator mechanical specification mean that the required engine rpm must be a minimum, maximum 1800 rpm or both? Could it be more or is the chance to ruin it a possibility? I want to stay safe.2) Obviously I'm assuming the 25 hp engine requirement is a minimum but how much bigger can it be without wet stacking problems?3) With these generator output specifications can I power my household without damaging anything?I was planning diesel (still researching brands) and connecting direct. Thoughts?
- 1) The 1800 RPM specification is the speed which will produce the 60 Hz output. This frequency is critical in some of your household electronics, maybe. If the speed is lower than 1800 RPM, the hertz will be lower. If speed is higher, the hertz will be higher. 2) The 25 HP driver is probably sufficient for your generator. A more powerful engine will not return the value for the extra cost of the larger driver. However, a larger driver will give you perhaps a better frequency control. 12.5 KW is (in theory) 12500 / 746 16.75 HP. I'm not sure what 'wet stacking' is. 3) .It will power most households. You may have some problem starting a large AC unit, if you have your electric clothes dryer, stove, oven and a larger lighting load on at the time it comes on. TexMav
- Q: I really need to know to know this.@ two days old. my baby was subjected to a high level of diesel fumes coming in from the hospital vents. Due to testing of generators and backed up through vent. she was in the room roughly 30 minutes what kinda damage should I be concerned about. should I be concerned? how long would it stay in lungs and the blood? please if you know.thanks
- After exposure to diesel gas fumes, if not, taken for treatment of oxygen inhalation in an incubator,0r oxygen tent -----the effect will be fatal ---byway of mucus collection and respiratory interference of gaseous exchange leading to fatality because of brain damage,for a continued exposure for more than 30minutes ---please read ---diesel-byproduct-result-in-brain damege
- Q: i have an amida lt5000 light tower/generator. its 22 hp, 120/240, 8.5 kw., 2 cylinder diesel motor, its pull behind type, its got 6 lights on the tower and stands up to like 40 feet. its got surface rust in some spots, its not the best looking but how much could i get 4 it? i cant find prices on OKorder or anything
- It would depend on who needs it. Check with any Rental places in your area that may have one. They may also be interested in buying it.
- Q: I recently purchased a CAT turbo diesel generator. I checked the oil and it had water in it. After a good bit of clear water came out the oil started to drain. It could best be described as the color and consistency of a vanilla milk shake. I was told by a friend to mix some diesel with the oil and agitate it to mix it up, then to drain the oil. After the system was clear, i put fresh oil in until it reached the fill line. I started up the engine and let it run for about two hours. It was smoking white from the exhaust stack. I have also noticed that there is oil dripping from the exhaust stack. There also seems to be oil leaking from the turbo. Could this oil leak be causing the white smoke? I remained curious so i grabbed an infrared thermometer and started checking around. The exhaust manifold around the number 1 cylinder was about 100 degrees cooler than the other 3 cylinders. What the heck is going on? help would be much appreciated!
- When the temp is less that means the cylinder is not firing as often as the others, I agree sounds like water getting into the cylinder one way another from the description of the white smoke, you already know that from white milk shake stuff in the oil. The oil leak from the turbo is probably the main seal for the turbo. The oil from the exhaust is probably blow by. Engine is pretty much toast and needs rebuilt (if possible) or replaced. Running it with a water leak can cause bearing/ ring failure is probably evident from the oil coming out the exhaust.
- Q: I recently had solar Pannels installed. The panels generate enough electricity to power my house during the day. I use a 20kw silent diesel generator to power my house at night. I really hate my power provider PGE. If i tell them to shut off my power, Will they remove that tacky smart meter from my property?
- If you don't pay your electric bill, they'll come and take away the meter. No, if you don't have electric service they don't want you to have a meter.
- Q: i have a plan to supply electric power supply to a colony of around 250 houses each have a load of approximately : 3 x1.5 ton air conditioners and all the other stuff of household use. voltage required is 400v 3 phase or 240 volt single phase. my question is if some one can please calculate the requirement of load for the above requirement and what size of generator is required for this load. thanks
- With that large a system, you should get a quote from professionals. You need better numbers on power usage, both average and peak. And the pros can help with that. See if you can get a sample of 10 electric power bills and use that as an average to calculate the average power for all 250. Peak is difficult. They each have 4.5 ton worth AC? must be a hot climate. You can use 1.2 kW per ton, so that is 5.4 kW per house or 1.4 MW total just for the ACs Is there electric stoves, hot water, etc? that could double the above number. So we are up to perhaps 3 MW already. At that level, you probably need a higher voltage system, perhaps a 6 kV distribution system. That costs money, plus all the transformers, one per 2-4 house, plus all the underground digging. Assuming you want this underground, not on poles. Again, contact a company that does this, such as Siemens, Bosch, GE, they would be happy to give you a good quote. edit: when you look at the ratio of peak power to average power, you will see a large number, as high as 10. that means you could require a (eg) 3 MW generator although the average power is only 0.3 MW. That means the efficiency is low and the costa are high. That is why large power distribution systems are much better, as the peaks are not nearly as high, and also power companies have special units that are usually offline and come online to handle the peaks.