Electro Galvanized Wire:
Electro galvanized wire ranging from BWG8# to BWG16# is the mostly used for customers. We also offer thinner galvanized wire down to BWG5# or up to BWG28# upon customers specific order. Single coil package for electro galvanized wire can be as small as 10 kg and up to maximum 1000 kg per coil.
Electro Galvanized Wire Processing & Features:
This kind of galvanized wire is made with choice mild steel, through wire drawing, wire galvanizing and other processes. Electro galvanized wire has the characteristics of thick zinc coating, good corrosion resistance, firm zinc coating, etc.
Forms of Supply:
Electro galvanized wire can be supplied in the form of coil wire, spool wire or further processed into straightened cut wire or U type wire.
Electro galvanized wire applications:
Electro galvanized wire is mainly used in construction, express way fencing, binding of flowers and wire mesh weaving.
Electro galvanized iron wire, electro galvanized steel wire, electro galvanized wire.
BWG6-22 5.0MM-0.8MM.
Zinc coat: 5-25g/m2.
Tensile strength: 35-120kg/mm2.

ZINC COATING TABLE

SIZE mm
(g/㎡)Min. zinc coating
A
AB
B
C
D
E
F
A1
B2
≤0.25
18
15
12
5
〉0.25-0.40
25
20
12
5
〉0.40-0.50
25
20
15
8
〉0.50-0.60
25
20
15
8
〉0.60-0.80
20
15
10
〉0.80-1.20
25
18
10
〉1.20-1.60
25
18
12
〉1.60-1.80
100
70
40
30
20
〉1.80-2.20
105
80
50
40
20
〉2.20-2.50
110
80
55
40
25
〉2.50-3.00
120
90
70
45
25
〉3.00-4.00
100
85
60
30
〉4.00-5.00
110
95
70
40



Q:If 46 m of nichrome wire is to have a resistance of 12.0 Ω at 20°C, what diameter wire should be used? in mm
Resistance of a wire in Ω R = ρL/A ρ is resistivity of the material in Ω-m L is length in meters A is cross-sectional area in m? A = πr?, r is radius of wire in m resistivity Nichrome 150e-8 Ω-m 12 = (150e-8 Ω-m)(46m)/(πr?) solve for r, which would be the radius of the wire in meters. change to mm, and multiply by 2 to get diameter. .
Q:I have 12/3 wire running from the breaker box on a 20 amp breaker that powers a bathroom (2 lights and 2 receptacles). I want to splice into this and run 14/2 wire into the living room to run 6 recessed lights. Is this OK to do?
No, you can't extend a 20A circuit with 14 G wire. And you can't legally downgrade the existing 12 G wire circuit to a 15 A breaker. And you can't put two wires into a single breaker inside the panel. Fastest solution? Almost all brands of panel offer a two breakers in one slot or high density option. So you can get a new thing that fits in the space of one 15A breaker but has two breakers in it and two connection screws on it. Replace an existing 15A breaker with a high density 15/15 and hook up two 15A circuits. These are also available in unequal configurations - so you could get one that had a 15A and a 20A breaker in the space of a single 'normal' 15 or 20 A breaker. In some brands these high density breakers only fit in certain (closer to the mains connection) spaces - typically the top 15 or 20 breaker spaces. Slower solution. That 15 A breaker that you wanted to put two wires on? Follow the wire from it into the attic, cut it, put in a junction box and splice your new 14 G wire in there. Then again, what else is on that circuit and will 15 A supply it all?
Q:I just bought an exhaust tip with leds which needs to be wired up to the brake lights on my mazda 626. Can somebody tell me which colour wire it is (positive) on the wiring to the brake light? There are a few wires and I dont know which one it is! Thanx
get a 12 volt test light to find power and just ground it to the vehicles chassis if your not sure about the ground
Q:I get how to solder one wire to the inverter, but how do I do multiple wires? Do I connect end-on-end, or all at the same source? I couldn't find a good website for doing multiple wires...
EI is very easy, you can do them either way, all that you need to assure is the voltage gets into the wire. So end to end or all direct to the inverter either way works just fine. My problem is getting the wire exposed, it takes me more than one shot at it, lol..
Q:A potential difference of 13 V is found to produce a current of 0.37 A in a 3.1 m length of wire with a uniform radius of 0.42 cm.(a) What is the resistance of the wire? (b) What is the resistivity of the wire? Please show work.
Voltage (Volts) = Current (Amps) times Resistance (Ohms) or V=IxR = R = V/I = 13/0.37 = 35.14 Ohms Resistance = Resistivity * Length/Area The longer the wire is, the more resistance it has. The larger the crossectional area of the wire (pi times radius^2), the less resistance it has Longer wires have more resistance, thicker wires have less 35.14 = Resistivity * 3.1/pi*0.0042^2 Resistivity = 35.14*pi*0.0042^2/3.1 = 6.281 x 10^-4
Q:hi i was wondering if its possible to electrify chicken wire? i have chickens in some fields and they keep wondering and chicken wire is alot cheaper than buying proper electric fencing??
Electric Chicken Wire
Q:I am in the process of installing a new thermostat, but I ran into the problem: new thermostat has 4 ports W, Y, R and G. But the old thermostat has 5 wires: W, Y, G and B. I am not sure where B wire (black color) should go. Do I need to look for another thermostat that has a port for B wire?
The black wire should be for ground. You and try to connect it without the black first to see if everything works ok, if it does tape off the black and tape it to the other wires. If not look at your UPM diagram and see which port is for ground and it should hook up with that wire. But I would double check with the heat pump wiring diagram to see what that black goes to and verify that wire with a multimeter.
Q:Three parallel wires are each carrying a 4A current. ; wire A) is 6 mm from wire B) which is 3mm from wire C); The current in wires B and C are out of the paper, while A is into the paper. What is the magnitude and direction of the magnetic field halfway between wires A and B?I have tried using Biot-Savart Law but keep getting it wrong can someone please help? I also have an equation for two parallel wires but how do I relate it to two?
SO YOU HAVE TWO POINTS ON PAPER HAVING DISTANCE 2d. megnetic field zero will be on the mid point of this line. (there will be many points where the megnetic field will be zero but THERE IS ONLY ONE POINT ON PAPER)
Q:what gauge wires should i use for my 12'' alpine typr r SWR-1242D?
4 guage amp kit This one is the best SoundQuest SQK0 1/0 Gauge Copper-Clad Aluminum Wiring Kit Technical Details * 1/0 Gauge Power and Grounding Wires * Remote Wire, Speaker wire, and RCA Signal Wires * Fuse Block and Fuse * Various crimp style connectors
Q:I'm just wondering would i be able to connect a split 8 gauge wire with wire nuts like i'll explain:Use two wire nuts instead of one and divide the copper wire on both ends and wire nut both sides together with 2 nuts. The whole apparatus would look kinda like this:----lt;gt;---- with the wire nuts connecting the two arrow thingsThanks anyone
Even though you had been wise to make use of the noalox, or antioxidant, i might ratehr endorse that you get the suitable gauge of wire in copper and rewire the entire circuit. The intent that I say that's that your oven is a excessive resistance circuit and aluminum does no longer like high resistance. With excessive resistance on aluminum, the aluminum wire will start running or moving under the strain and can eventually burn out the connection. In the event you have got to leave it aluminum, don't use a wire nut, but get a split nut from an electrical provide, use teh same goop on it, then get two wrenches for the best way that you just ought to screw the break up bolt to the nut, tighten the item down as tight as humanly viable, the wrap it with a specified tape that the electrical give may also have. It's not the commonplace electrical tape, but a stretchable tape and also you wrap it tight at the least 3 or a bit of extra inches on all sides of the nut. This may insulate the connection in order that it are not able to be shorted out in any respect. Mine had the same aluminum connection and when I changed the stove, which was difficult wired to the stove, I simply replaced the entire wire. Mainly the field is just not too some distance away fromthe stove due to the fact it wants to be as just about it to decrease resistance. To scan what you have got performed, that you would be able to take a low-cost volt meter from Radio shack, set it on the correct settings for measuring voltage on 220, and if the needle goes to 220 + or - a bit, you're nice in the meanwhile.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords