• Double Suction Centrifugal Water Pump for Pump Station System 1
  • Double Suction Centrifugal Water Pump for Pump Station System 2
  • Double Suction Centrifugal Water Pump for Pump Station System 3
Double Suction Centrifugal Water Pump for Pump Station

Double Suction Centrifugal Water Pump for Pump Station

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
10000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

           High Quality Double Suction Centrifugal Water Pump

1.Structure of High Quality Double Suction Centrifugal Water Pump Description

The Single Stage Double Suction Split Casing Centrifugal Pump is designed for Irrigation, The casting is axially split, which permits removal of the complete rotor whish moving either piping or motor. Pumps generating high heads have double volute to reduce radial forces. Replaceable wear ring protect the casting at the impeller running clearances. Flange drilled to ISO, DIN, BS or ANSI. The close double suction impeller gives practically zero axial forces. Each impeller is statically and dynamically balanced according to ISO 1940.The pumps have a reduced number of parts and extensive interchangeability, which leads to minimum levels of inventory for customers and faster parts delivery. Vertical installation is a standard option with the same upper and lower casing parts. It is mounted for a space-saving configuration or when apace is at a premium. Soft packing or mechanical seal, grease or oil lubricated bearing is optional. Oil lubrication is with constant level oiler.

 

2.Main Features of High Quality Double Suction Centrifugal Water Pump

Compact structure

Attractive design

High efficiency, steady performance

big capacity, medium pressure

High concentricity of components

3. High Quality Double Suction Centrifugal Water Pump Images

Double Suction Centrifugal Water Pump for Pump Station

4. High Quality Double Suction Centrifugal Water Pump Specification

Material 

Cast Iron, Ductile Cast Iron, Cast Steel, Stainless Steel or Duplex S.S

Impeller

Cast Iron, Bronze, Duplex S.S, Stainless Steel

Shaft

C-Steel, Cr-Steel, Stainless Steel

Wearing Ring

Cast Iron, Brass, Stainless Steel

Capacity/Q

Up to 25000m3/h,

Up to 110000gpm

Head/H

Up to 280m,

Up to 800 feet

Temperature/T

Up to 200degree

Speed/n

2900/1450/980/740/580 rpm

3500/1750/1180/890/710rpm

5.FAQ

What is the applications

Besides irrigation and drainage pumping Station, the Single Stage Double Suction Split Casing Centrifugal Pump also can be used for Circulation water for air-condition, water supply for industry and building, and other waterworks

How to guarantee the quality of the products

Q:What is a solution pump?
(4) smooth running, low noise, no lubrication, no lubrication and low noise due to the absence of rolling bearings and motor fans(5) a wide range of use, the high temperature, high pressure, low temperature, high melting point and other conditions are able to meet the requirements2.2 shielding pump shortcomings(1) because the shielding pump adopts sliding bearings and is lubricated by the medium to be transported, the medium with poor lubricity should not be transported by shielding pump. Generally, the viscosity of the pump medium is 0.20mPa.s.(2) the efficiency of shielding pump is usually lower than that of single end mechanical seal centrifugal pump, which is approximately equal to that of double end mechanical seal centrifugal pump(3) long time in small flow operation, shielding pump efficiency is low, will lead to heat, make the liquid evaporation, and cause the pump to dry, and thus damage the sliding bearingsCanned pumps can be divided into the following types: 1) basic type 2) reverse circulation type 3) high temperature type 4) high melting point type 5) high pressure type6) self priming 7) multi stage 8) mud type
Q:What does electromechanical vector pump mean?
Scope of application is;Residents living water: such as high-rise buildings, residential areas, villas and so onPublic places such as hospitals, schools, gymnasiums, golf courses, airports, etc
Q:What is the function of the heating pump system for the water pump design?
Will cause some of the internal friction gap disappeared, the coupling center damage. In this case, starting the pump inevitably results in vibration, friction, etc.
Q:Which nuclear submarines use the shaftless pump technology?
Shaftless pumping technology and Simulation of shark skin technology are all the next generation of submarine propulsion technology. At present, there is no submarine in the world.
Q:What is the principle of a turbopump?
The working conditions of the turbine are different from those of the medium used, so the structure of the turbine is varied, but the basic working principle is similar. The most important component of a turbine is a rotating element (rotor or impeller) mounted on a turbine shaft with blades uniformly arranged along the circumference. The energy of the fluid is converted into kinetic energy in the flow through the nozzle, and when the fluid passes through the rotor, the fluid impacts the blade and drives the rotor to rotate, thus driving the turbine shaft to rotate. The turbine shaft drives the other machinery directly or through the transmission mechanism, and outputs mechanical work.
Q:Know flow and lift how to calculate the pump power?
N=Q.H.g. P / nN - motor power, kWH - pump head, MQ - pump flow, m^3/sG - gravity acceleration g=9.81
Q:What is the cause of the damage of pump bearings?
Is the water pump motor overheating or damaged leaves overheating, resulting in overheating bearings, lubricating oil dry, excessive wear and tear guide system damage
Q:Roots pump and dry pumpRecently involved in the work of the vacuum pump, don't understand this, is a ads602 vacuum pump, composed of roots pump and dry pump, is pre pumped to the 500mtorr equipment, the main pumping vacuum continues to 10mtorr, where the roots pump and dry pumps must be used? What role they play respectively. The so-called dry pump? Is refers to one kind of the pump, the pump is many dry pump? Also do not understand how the work of automatic switching system for pre pumping, the main pump, pump work alone did not connect system ah (of course there are even a butterfly) teach?
Here the roots pump and dry pump must be used, because the roots pump is not used alone, and must be a stage vacuum pump (pre vacuum pump can be dry pump, water ring vacuum pump and rotary vane vacuum pump can be, you here with dry pump series)
Q:There are 6 pumps, two indoor fire hydrant pumps, two spray pumps, two outdoor pumps, three units, one master and one spare control cabinet. From the control room to the control cabinet, is there only 3 lines or 9 lines?... How do I get it? Where does the hydrant line come from?
You said the three line refers to the control room, the control cabinet, the main pump directly start the straight line of water pump. Each pump should be equipped with single straight line Kai, reported that the cabinet Jinglian dynamic multi line linkage control board has three buttons corresponding to a remote spray pump, fire hydrant pump, pump start outdoor fire hydrant. This requires three straight lines, from the cabinet to the three pump control cabinet, which is the 9 line you call. The water pump control cabinet is provided with a terminal for supplying a remote pump. By looking at the wiring diagram of the water pump control box, you can find the technical personnel of the control cabinet manufacturer if you can't find them.
Q:How long does the fine stone pump need maintenance? What should I pay attention to?
Daily maintenance of concrete pump, that is, routine maintenance in use, including inspection, cleaning, lubrication, fastening, adjustment, leak hunting, supplement of hydraulic oil, etc.. 8.1 hydraulic components inspection, due to the complexity of the equipment, we recommend practical experts to carry out the inspection of hydraulic system. If a fault is found, check the cause and repair the entire loop before proceeding to any operation. - found that oil has diarrhea, excluding leakage reasons. - inspect safety valves, hydraulic systems, steel tubes and hoses, fittings, cylinders, and find any wear and tear (pipe explosion may cause very serious consequences)

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords