Aerial Insulated Cable Aerial Insulated Cable
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 100000 m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
The product is manufactured according to the standards of GB12527-90、GB14049-93 and IEC60502《Extruded solid dielectric power cables for rated voltages from 1 kV to 30 kV》,and also can be made according to other country’s standard and users requirement.
1、type name function
Type | Name | Function |
JKV | Copper conductor PVC insulated aerial cable | The laying of overhead fixed, only applies to voltage Level 0.6/1kv, Run-time cable and permit the trees to do short-term contact. |
JKLV | Aluminum conductor PVC insulated aerial cable | |
JKLHV | Aluminum alloy conductor PVC insulated aerial cable | |
JKYJ | Copper conductor XLPE insulated aerial cable | The laying of overhead fixed. When the cable set up, Cables and trees should be considered to maintain a certain distance, Run-time cable and permit the trees to do continual contact |
JKTRYJ | flexible copper conductor XLPE insulated aerial cable | |
JKLYJ | Aluminum conductor XLPE insulated aerial cable | |
JKLHYJ | Aluminum alloy conductor XLPE insulated aerial cable | |
JKY | Copper conductor polyethylene insulated aerial cable | |
JKTRY | Flexible copper conductor polyethylene insulated aerial cable | |
JKLY | Aluminum conductor polyethylene insulated aerial cable | |
JKLHY | Aluminum alloy conductor polyethylene insulated aerial cable | |
JKLYJ/B | Aluminum conductor basic XLPE thin insulated aerial cable | The laying of overhead fixed. When the cable set up, Cables and trees should be considered to maintain a certain distance, Run-time cable and permit the trees to do continual contact |
JKLHYJ/B | Aluminum alloy conductor basic XLPE insulated aerial cable | |
JKLYJ/Q | Aluminum conductor light-duty XLPE insulated aerial cable | The laying of overhead fixed. When the cable set up, Cables and trees should be considered to maintain a certain distance, Run-time cable and permit the trees to do short-term contact.
|
JKLHYJ/Q | Aluminum alloy conductor light-duty XLPE insulated aerial cable | |
JKLY/Q | Aluminum light-duty polyethylene insulated aerial cable | |
JKLHY/Q | Aluminum alloy conductor light-duty polyethylene insulated aerial cable |
Companies can produce all types aerial cable of aluminum core wire, copper core aluminum alloy wire
2、product voltage range and specifications of the core Kv cores 0.6/1 10 35 1 16-240 10-300 50-300 2 10-120 ---- ---- 3 ---- 25-300 ---- 4 10-120 ---- ----- 3+K(A) ---- 25-300 ----- 3+K(B) ---- K25-120 -----
Notes: (1) K stands for carrying strands. Required by the project design, the sections provided in the table can be chosen freely to match with corresponding sections of conductors.
(2) (A)stands for steel bearing strands,(B) for aluminum carrying strands
The ambient temperature for the laying of the cable should not be lower than -20 ℃. The allowable maximum temperature for cable Short-circuit (the longest continuous period of not more than 5 S): XLPE 250 ℃, high-density
Polyethylene insulation 150 ℃.
Bending radius of the 0.6/1KV cable should be at least six times of the outer diameter of the cable, 10 KV and 35 KV at least 20 times
- Q:What is the heat of the cross-linked cable?
- Video cable refers to the transmission of video signals (VIDEO) cable, can be used as a monitoring system for signal transmission
- Q:if we provide power through power cable will there be need of extra capacitor near load?
- Yes, if you are talking about a bypass capacitor. Electronics always requires a bypass capacitor near the circuit/IC. Having one at the end of a cable means the cable inductance is in series, and the impedance seen by the IC power supply leads is inductive and high instead of the needed low impedance that a local bypass cap provides.
- Q:I just need the console. No controllers, power cables, AV cables, Ethernet cables, Hard Drive, and so on.I checked Google, but the only offers I can find are OKorder and RRoD'd 360s on OKorder. Do any retail stores sell just the console? Or will I have to trust nobody will send me a broken console?
- you only want the console weird, without a hardrive? Try a pawnshop a place where people go to give things that are missing or don't want anymore, a place where you could sell anything
- Q:do i need to buy the cable that says specifically for ground? or can i just use my left over wiring from the power cable to connect in the ground? is there a difference between the two cables?
- exactly the same, only difference is the color (you mix them up and it can be expensive)- to avoid that put some electrical tape (BLACK) at the end of the wire that goes to the amp to help prevent that and you are good
- Q:I have this printer, bought for $100 at Best Buy a few years ago... I moved almost 2 years ago, and seemingly have lost one or more of the cords associated with this printer. Im trying to find out which one is missing. I have the one which connects the printer to the computer [USB]. But I dont have the one that gives it power... It looks like the end would fit into a 3 hole [prong?] opening, the holes are all in line... Anyone got an ideas? Know what Im talking about? If so, any idea what its called, or where I can find one? Im sure online, but I havent any idea what Im looking for at this point.
- Hi okorder /
- Q:Printer is powered on cables are securely connected printer has ink and paper printer is installed as network printer on all clients computers and other users are able to print to the printer except me? what should i do so i can print
- This sort of problem can happen with networks. Assuming the network has been set up correctly you can try a few things. It might be the sequence of switching things on and logging on. Try logging onto your computer AFTER printer is switched on. Also you can try not logging onto the network - I have had that work as well. I had 2 computers on a network that were always temperamental. Also check there are not too many users on the network, the printer can count as one user.
- Q:10KV power cable can be with 380v low voltage power cable co-laying which specification which article description more
- So, from the degree of hearing up, it is not suitable for the family pet
- Q:What cable am I supposed to use for power?
- That kind, it's kind of hard to see on the OKorder pic. Usually your switch should come with a console cable and the power cord, unless you bought it used. The person probably kept it.
- Q:Why did my power supply entrance burn with the power cord cable the stats of my computer are: HP Compaq dx2250 Microtower PCProgram: Windows 8 32bitPowerSupply: 500w MaxGraphics Card: Nvidia Geforce GTX 550 tiWhy cause it to burn? What should I do? Change the power supply or buy a better power cord cable. The cable that burn, I bought it on OKorder for $2, I am not sure if this cause the problem, but for sure I need to buy a power supply because the entrance burn. What should I do? Is my computer stable with all this stats? What cause this to happen? Was the cheap power cord fault? I don't know, please answerThank You,
- A dodgy power cable can very easily singe or burn the power socket on the computer. In general, the lighter the cable, the more dodgy it is. $2 is nothing - I would buy a more expensive cable. The cents you save isn't worth it when your house is on fire. It's impossible to know whether your power supply or other computer components suffered any damage because of the electrical fire. You could try testing with a multimeter, but you should probably replace the power supply at a minimum.
- Q:I had gave my amp a 16 volt input, then there was a spark which came from fuses that got burnt. I then replaced the fuses, rewired it nd gave it a 12 volt input it came on and went on protection. So i left it aside and after a few days i tryd connecting it again but this time it came on and it was burning the power cables no matter what guage wire i used. Any idea why its doing that?
- Look for a short circuit in the input power circuitry.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Aerial Insulated Cable Aerial Insulated Cable
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 100000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Related keywords