• Aerial Insulated Cable Aerial Insulated Cable System 1
  • Aerial Insulated Cable Aerial Insulated Cable System 2
Aerial Insulated Cable Aerial Insulated Cable

Aerial Insulated Cable Aerial Insulated Cable

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
100 m
Supply Capability:
100000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

The  product is manufactured according to the standards of  GB12527-90、GB14049-93 and IEC60502《Extruded solid dielectric power  cables for rated voltages from 1 kV to 30 kV》,and also can be made  according to other country’s standard and users requirement.


1、type name function


Type

Name

Function

JKV

Copper conductor PVC insulated aerial cable

The  laying of overhead fixed, only applies to voltage Level 0.6/1kv,  Run-time cable and permit the trees to do short-term contact.

JKLV

Aluminum conductor PVC insulated aerial cable

JKLHV

Aluminum alloy conductor PVC insulated aerial cable

JKYJ

Copper conductor XLPE insulated aerial cable

The  laying of overhead fixed. When the cable set up, Cables and trees  should be considered to maintain a certain distance, Run-time cable and  permit the trees to do continual contact

JKTRYJ

flexible copper conductor XLPE insulated aerial cable

JKLYJ

Aluminum conductor XLPE insulated aerial cable

JKLHYJ

Aluminum alloy conductor XLPE insulated aerial cable

JKY

Copper conductor polyethylene insulated aerial cable

JKTRY

Flexible copper conductor polyethylene insulated aerial cable

JKLY

Aluminum conductor polyethylene insulated aerial cable

JKLHY

Aluminum alloy conductor polyethylene insulated aerial cable

JKLYJ/B

Aluminum conductor basic XLPE thin insulated aerial cable

The  laying of overhead fixed. When the cable set up, Cables and trees  should be considered to maintain a certain distance, Run-time cable and  permit the trees to do continual contact

JKLHYJ/B

Aluminum alloy conductor basic XLPE insulated aerial cable

JKLYJ/Q

Aluminum conductor light-duty XLPE insulated aerial cable

The  laying of overhead fixed. When the cable set up, Cables and trees  should be considered to maintain a certain distance, Run-time cable and  permit the trees to do short-term contact.

 

 

 

JKLHYJ/Q

Aluminum alloy conductor light-duty XLPE insulated aerial cable

JKLY/Q

Aluminum light-duty polyethylene insulated aerial cable

JKLHY/Q

Aluminum alloy conductor light-duty polyethylene insulated aerial cable

Companies can produce all types aerial cable of aluminum core  wire, copper core aluminum alloy wire

2、product voltage range and specifications of the core


             Kv

cores

 

0.6/1

 

10

 

35

1

16-240

10-300

50-300

2

10-120

----

----

3

----

25-300

----

4

10-120

----

-----

3+K(A)

----

25-300

-----

3+K(B)

----

K25-120

-----


Notes: (1) K stands  for carrying strands. Required by the project design, the sections  provided in the table can be chosen freely to match with corresponding  sections of conductors.    
       (2) (A)stands for steel bearing strands,(B) for aluminum carrying strands

 

3、Performance requirements for laying the cable
     The ambient temperature for the laying of the cable should not be lower  than -20 ℃. The allowable maximum temperature for cable Short-circuit  (the longest continuous period of not more than 5 S): XLPE 250 ℃,  high-density
Polyethylene insulation 150 ℃. 
    Bending radius  of the 0.6/1KV cable should be at least six times of the outer diameter  of the cable, 10 KV and 35 KV at least 20 times

Q:What is the heat of the cross-linked cable?
Video cable refers to the transmission of video signals (VIDEO) cable, can be used as a monitoring system for signal transmission
Q:if we provide power through power cable will there be need of extra capacitor near load?
Yes, if you are talking about a bypass capacitor. Electronics always requires a bypass capacitor near the circuit/IC. Having one at the end of a cable means the cable inductance is in series, and the impedance seen by the IC power supply leads is inductive and high instead of the needed low impedance that a local bypass cap provides.
Q:I just need the console. No controllers, power cables, AV cables, Ethernet cables, Hard Drive, and so on.I checked Google, but the only offers I can find are OKorder and RRoD'd 360s on OKorder. Do any retail stores sell just the console? Or will I have to trust nobody will send me a broken console?
you only want the console weird, without a hardrive? Try a pawnshop a place where people go to give things that are missing or don't want anymore, a place where you could sell anything
Q:do i need to buy the cable that says specifically for ground? or can i just use my left over wiring from the power cable to connect in the ground? is there a difference between the two cables?
exactly the same, only difference is the color (you mix them up and it can be expensive)- to avoid that put some electrical tape (BLACK) at the end of the wire that goes to the amp to help prevent that and you are good
Q:I have this printer, bought for $100 at Best Buy a few years ago... I moved almost 2 years ago, and seemingly have lost one or more of the cords associated with this printer. Im trying to find out which one is missing. I have the one which connects the printer to the computer [USB]. But I dont have the one that gives it power... It looks like the end would fit into a 3 hole [prong?] opening, the holes are all in line... Anyone got an ideas? Know what Im talking about? If so, any idea what its called, or where I can find one? Im sure online, but I havent any idea what Im looking for at this point.
Hi okorder /
Q:Printer is powered on cables are securely connected printer has ink and paper printer is installed as network printer on all clients computers and other users are able to print to the printer except me? what should i do so i can print
This sort of problem can happen with networks. Assuming the network has been set up correctly you can try a few things. It might be the sequence of switching things on and logging on. Try logging onto your computer AFTER printer is switched on. Also you can try not logging onto the network - I have had that work as well. I had 2 computers on a network that were always temperamental. Also check there are not too many users on the network, the printer can count as one user.
Q:10KV power cable can be with 380v low voltage power cable co-laying which specification which article description more
So, from the degree of hearing up, it is not suitable for the family pet
Q:What cable am I supposed to use for power?
That kind, it's kind of hard to see on the OKorder pic. Usually your switch should come with a console cable and the power cord, unless you bought it used. The person probably kept it.
Q:Why did my power supply entrance burn with the power cord cable the stats of my computer are: HP Compaq dx2250 Microtower PCProgram: Windows 8 32bitPowerSupply: 500w MaxGraphics Card: Nvidia Geforce GTX 550 tiWhy cause it to burn? What should I do? Change the power supply or buy a better power cord cable. The cable that burn, I bought it on OKorder for $2, I am not sure if this cause the problem, but for sure I need to buy a power supply because the entrance burn. What should I do? Is my computer stable with all this stats? What cause this to happen? Was the cheap power cord fault? I don't know, please answerThank You,
A dodgy power cable can very easily singe or burn the power socket on the computer. In general, the lighter the cable, the more dodgy it is. $2 is nothing - I would buy a more expensive cable. The cents you save isn't worth it when your house is on fire. It's impossible to know whether your power supply or other computer components suffered any damage because of the electrical fire. You could try testing with a multimeter, but you should probably replace the power supply at a minimum.
Q:I had gave my amp a 16 volt input, then there was a spark which came from fuses that got burnt. I then replaced the fuses, rewired it nd gave it a 12 volt input it came on and went on protection. So i left it aside and after a few days i tryd connecting it again but this time it came on and it was burning the power cables no matter what guage wire i used. Any idea why its doing that?
Look for a short circuit in the input power circuitry.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords